Base-isolated structure equipped with tuned liquid column damper: An experimental study. (1st February 2019)
- Record Type:
- Journal Article
- Title:
- Base-isolated structure equipped with tuned liquid column damper: An experimental study. (1st February 2019)
- Main Title:
- Base-isolated structure equipped with tuned liquid column damper: An experimental study
- Authors:
- Furtmüller, Thomas
Di Matteo, Alberto
Adam, Christoph
Pirrotta, Antonina - Abstract:
- Highlights: Experimental verification of control performance for hybrid controlled system. Identification of relevant dynamic nonlinear base-isolation and TLCD parameters. Derivation of analytical model verifying experimental results. Abstract: In this study, a novel passive vibration control strategy is investigated experimentally, where a Tuned Liquid Column Damper protects a base-isolated structure. The Tuned Liquid Column Damper is attached to the base, in contrast to typical attachment points of passive energy dissipation devices in high-rise buildings at elevated levels. Experiments on a base-excited small-scale three-story shear frame are conducted in order to study effects of both control devices – base-isolation and Tuned Liquid Column Damper – on the structural model. The dynamic properties of the stand-alone shear frame and the base-isolation subsystem are derived using standard dynamic test methods based on displacement and acceleration response measurements. In the base-isolation subsystem both viscous damping and friction effects are identified. The water level of the Tuned Liquid Column Damper is tracked by means of computational image processing of video recordings, facilitating the identification of the fundamental liquid motion mode as well as the nonlinear damping properties. An experimental parametric study is conducted for three Tuned Liquid Column Damper devices with different frequency tuning ratios. The assessment of the hybrid control strategy isHighlights: Experimental verification of control performance for hybrid controlled system. Identification of relevant dynamic nonlinear base-isolation and TLCD parameters. Derivation of analytical model verifying experimental results. Abstract: In this study, a novel passive vibration control strategy is investigated experimentally, where a Tuned Liquid Column Damper protects a base-isolated structure. The Tuned Liquid Column Damper is attached to the base, in contrast to typical attachment points of passive energy dissipation devices in high-rise buildings at elevated levels. Experiments on a base-excited small-scale three-story shear frame are conducted in order to study effects of both control devices – base-isolation and Tuned Liquid Column Damper – on the structural model. The dynamic properties of the stand-alone shear frame and the base-isolation subsystem are derived using standard dynamic test methods based on displacement and acceleration response measurements. In the base-isolation subsystem both viscous damping and friction effects are identified. The water level of the Tuned Liquid Column Damper is tracked by means of computational image processing of video recordings, facilitating the identification of the fundamental liquid motion mode as well as the nonlinear damping properties. An experimental parametric study is conducted for three Tuned Liquid Column Damper devices with different frequency tuning ratios. The assessment of the hybrid control strategy is based on the determined transfer functions of the studied setups. Experimental outcomes confirm recent theoretical findings that a passive hybrid control strategy combining a base-isolation and a Tuned Liquid Column Damper reduces the displacement demand of the base-isolation subsystem as well as the total story acceleration demand if both control devices are properly tuned. … (more)
- Is Part Of:
- Mechanical systems and signal processing. Volume 116(2019)
- Journal:
- Mechanical systems and signal processing
- Issue:
- Volume 116(2019)
- Issue Display:
- Volume 116, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 116
- Issue:
- 2019
- Issue Sort Value:
- 2019-0116-2019-0000
- Page Start:
- 816
- Page End:
- 831
- Publication Date:
- 2019-02-01
- Subjects:
- Base-isolated structure -- Tuned liquid column damper -- Optimal design -- Hybrid control strategy -- Small-scale experiment
Structural dynamics -- Periodicals
Vibration -- Periodicals
Constructions -- Dynamique -- Périodiques
Vibration -- Périodiques
Structural dynamics
Vibration
Periodicals
621 - Journal URLs:
- http://www.sciencedirect.com/science/journal/08883270 ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0888-3270;screen=info;ECOIP ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ymssp.2018.06.048 ↗
- Languages:
- English
- ISSNs:
- 0888-3270
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5419.760000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20466.xml