Non-rigid alignment pipeline applied to human gait signals acquired with optical motion capture systems and inertial sensors. (2nd January 2020)
- Record Type:
- Journal Article
- Title:
- Non-rigid alignment pipeline applied to human gait signals acquired with optical motion capture systems and inertial sensors. (2nd January 2020)
- Main Title:
- Non-rigid alignment pipeline applied to human gait signals acquired with optical motion capture systems and inertial sensors
- Authors:
- Soussé, Rubén
Verdú, Jorge
Jauregui, Ricardo
Ferrer-Roca, Ventura
Balocco, Simone - Abstract:
- Abstract: An accurate gait characterization is fundamental for diagnosis and treatment in both clinical and sportive fields. Although several devices allow such measurements, the performance comparison between the acquired signals may be a challenging task. A novel pipeline for the accurate non-rigid alignment of gait signals is proposed. In this paper, the measurements of Inertial Measurement Units (IMU) and Optical Motion Capture Systems (OMCAP) are aligned using a modified version of the Dynamic Time Warping (DTW) algorithm. The differences between the two acquisitions are evaluated using both global (RMSE, Correlation Coefficient (CC)) and local (Statistical Parametric Mapping (SPM)) metrics. The method is applied to a data-set obtained measuring the gait of ten healthy subjects walking on a treadmill at three different gait paces. Results show a global bias between the signal acquisition of 0.05°. Regarding the global metrics, a mean RMSE value of 2.65° (0.73°) and an average CC value of 0.99 (0.01) were obtained. The SPM profile shows, in each gait cycle phase, the percentage of cases when two curves are statistically identical and reaches an average of 48% (22%).
- Is Part Of:
- Journal of biomechanics. Volume 98(2020)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 98(2020)
- Issue Display:
- Volume 98, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 98
- Issue:
- 2020
- Issue Sort Value:
- 2020-0098-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-01-02
- Subjects:
- Inertial measurement units -- Dynamic time warping -- Statistical parametric mapping -- Optical motion capture systems
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2019.109429 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20491.xml