Cardiac resynchronization therapy with or without defibrillator in patients with heart failure. Issue 1 (6th September 2021)
- Record Type:
- Journal Article
- Title:
- Cardiac resynchronization therapy with or without defibrillator in patients with heart failure. Issue 1 (6th September 2021)
- Main Title:
- Cardiac resynchronization therapy with or without defibrillator in patients with heart failure
- Authors:
- Schrage, Benedikt
Lund, Lars H
Melin, Michael
Benson, Lina
Uijl, Alicia
Dahlström, Ulf
Braunschweig, Frieder
Linde, Cecilia
Savarese, Gianluigi - Abstract:
- Abstract: Aims: Randomized data on the efficacy/safety of cardiac resynchronization therapy with vs. without defibrillator (CRT-D, -P) in heart failure with reduced ejection fraction (HFrEF) are scarce. We aimed to evaluate survival associated with use of CRT-D vs. CRT-P in a contemporary cohort with HFrEF. Methods and results: Patients from Swedish HF Registry treated with CRT-D/CRT-P and fulfilling criteria for primary prevention defibrillator use were included. Logistic regression was used to evaluate predictors of CRT-D non-use. All-cause mortality was compared in CRT-D vs. CRT-P by Cox regression in a 1 : 1 propensity-score-matched cohort. Of 1988 patients with CRT, 1108 (56%) had CRT-D and 880 (44%) CRT-P. Older age, higher ejection fraction (EF), female sex, and the lack of referral to HF nurse-led outpatient clinic were major determinants of CRT-D non-use. After matching, 645 CRT-D patients were compared with 645 with CRT-P. The CRT-D use was associated with lower 1- and 3-year all-cause mortality [hazard ratio (HR):0.76, 95% confidence interval (CI):0.58–0.98; HR: 0.82, 95% CI: 0.68–0.99, respectively]. Results were consistent in all pre-specified subgroups except for CRT-D use being associated with lower 3-year mortality in patients with an EF < 30% but not in those with an EF ≥ 30% (HR: 0.73, 95% CI: 0.59–0.89 and HR: 1.24, 95% CI: 0.83–1.85, respectively; P -interaction = 0.02). Conclusion: In a contemporary HFrEF cohort, CRT-D was associated with lower mortalityAbstract: Aims: Randomized data on the efficacy/safety of cardiac resynchronization therapy with vs. without defibrillator (CRT-D, -P) in heart failure with reduced ejection fraction (HFrEF) are scarce. We aimed to evaluate survival associated with use of CRT-D vs. CRT-P in a contemporary cohort with HFrEF. Methods and results: Patients from Swedish HF Registry treated with CRT-D/CRT-P and fulfilling criteria for primary prevention defibrillator use were included. Logistic regression was used to evaluate predictors of CRT-D non-use. All-cause mortality was compared in CRT-D vs. CRT-P by Cox regression in a 1 : 1 propensity-score-matched cohort. Of 1988 patients with CRT, 1108 (56%) had CRT-D and 880 (44%) CRT-P. Older age, higher ejection fraction (EF), female sex, and the lack of referral to HF nurse-led outpatient clinic were major determinants of CRT-D non-use. After matching, 645 CRT-D patients were compared with 645 with CRT-P. The CRT-D use was associated with lower 1- and 3-year all-cause mortality [hazard ratio (HR):0.76, 95% confidence interval (CI):0.58–0.98; HR: 0.82, 95% CI: 0.68–0.99, respectively]. Results were consistent in all pre-specified subgroups except for CRT-D use being associated with lower 3-year mortality in patients with an EF < 30% but not in those with an EF ≥ 30% (HR: 0.73, 95% CI: 0.59–0.89 and HR: 1.24, 95% CI: 0.83–1.85, respectively; P -interaction = 0.02). Conclusion: In a contemporary HFrEF cohort, CRT-D was associated with lower mortality compared with CRT-P. The CRT-D use was less likely in older patients, females, and in patients not referred to HF nurse-led outpatient clinic. Our findings support the use of CRT-D vs. CRT-P in HFrEF, in particular with severely reduced EF. … (more)
- Is Part Of:
- Europace. Volume 24:Issue 1(2022)
- Journal:
- Europace
- Issue:
- Volume 24:Issue 1(2022)
- Issue Display:
- Volume 24, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 24
- Issue:
- 1
- Issue Sort Value:
- 2022-0024-0001-0000
- Page Start:
- 48
- Page End:
- 57
- Publication Date:
- 2021-09-06
- Subjects:
- Heart failure -- Heart failure with reduced ejection fraction -- Implantable cardioverter-defibrillator -- Cardiac resynchronization therapy -- Primary prevention -- Swedish Heart Failure Registry
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euab233 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20502.xml