High frequency ultrasonography: reliable tool to measure skin fibrosis in SSC? A systematic literature review and additional pilot study. (25th May 2021)
- Record Type:
- Journal Article
- Title:
- High frequency ultrasonography: reliable tool to measure skin fibrosis in SSC? A systematic literature review and additional pilot study. (25th May 2021)
- Main Title:
- High frequency ultrasonography: reliable tool to measure skin fibrosis in SSC? A systematic literature review and additional pilot study
- Authors:
- Vanhaecke, Amber
Cutolo, Maurizio
Heeman, Lise
Vilela, Veronica
Deschepper, Ellen
Melsens, Karin
Smith, Vanessa - Abstract:
- Abstract: Objectives: To investigate the reliability of high frequency ultrasound (HFUS) in measuring skin fibrosis in SSc. Methods: First, a systematic review (according to PRISMA) was conducted to identify studies that documented HFUS' reliability in SSc as a primary outcome. Then, in an additional pilot study, the inter- and intra-rater reliability of two investigators performing HFUS for dermal thickness (DT) measurements in a standardized manner across all 17 areas of the modified Rodnan Skin Score was evaluated in a group of 59 SSc patients and descriptively in 44 healthy controls (HC). As an external validation, DT measurements by HFUS were performed in a separate group of 30 SSc patients by the same first and another third investigator. Results: The systematic review retained few (4/1719 unique records) small-scale studies, with mixed study populations (combining SSc and HC). The reported data herein are suggestive of the inter-/intra-rater reliability of HFUS (intra-class correlation coefficient [ICCs] ranging 0.65–0.94/0.55–0.96, respectively). Additionally, in our pilot study, inter-/intra-rater reliability was good-to-excellent in both SSc groups and HC (ICCs ranging 0.70–0.97/0.70–0.98 and 0.65–0.95/0.63–0.96, respectively). Conclusion: The identified small-scale studies were not only combining data from SSc and HC, they were also heterogeneous in terms of technical aspects (probes and frequency), image acquisition methods ([number of] areas assessed) andAbstract: Objectives: To investigate the reliability of high frequency ultrasound (HFUS) in measuring skin fibrosis in SSc. Methods: First, a systematic review (according to PRISMA) was conducted to identify studies that documented HFUS' reliability in SSc as a primary outcome. Then, in an additional pilot study, the inter- and intra-rater reliability of two investigators performing HFUS for dermal thickness (DT) measurements in a standardized manner across all 17 areas of the modified Rodnan Skin Score was evaluated in a group of 59 SSc patients and descriptively in 44 healthy controls (HC). As an external validation, DT measurements by HFUS were performed in a separate group of 30 SSc patients by the same first and another third investigator. Results: The systematic review retained few (4/1719 unique records) small-scale studies, with mixed study populations (combining SSc and HC). The reported data herein are suggestive of the inter-/intra-rater reliability of HFUS (intra-class correlation coefficient [ICCs] ranging 0.65–0.94/0.55–0.96, respectively). Additionally, in our pilot study, inter-/intra-rater reliability was good-to-excellent in both SSc groups and HC (ICCs ranging 0.70–0.97/0.70–0.98 and 0.65–0.95/0.63–0.96, respectively). Conclusion: The identified small-scale studies were not only combining data from SSc and HC, they were also heterogeneous in terms of technical aspects (probes and frequency), image acquisition methods ([number of] areas assessed) and definitions used for skin thickness, which prevents drawing unequivocal conclusions. Despite these limitations, our standardized pilot study corroborated the findings in literature, paving the way for the applicability of HFUS as a reliable (complementary) tool to quantify skin fibrosis in SSc. … (more)
- Is Part Of:
- Rheumatology. Volume 61:Number 1(2022)
- Journal:
- Rheumatology
- Issue:
- Volume 61:Number 1(2022)
- Issue Display:
- Volume 61, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 61
- Issue:
- 1
- Issue Sort Value:
- 2022-0061-0001-0000
- Page Start:
- 42
- Page End:
- 52
- Publication Date:
- 2021-05-25
- Subjects:
- systemic sclerosis -- ultrasound -- skin fibrosis -- reliability -- systematic literature review
Rheumatism -- Periodicals
Rheumatology -- Periodicals
616.723005 - Journal URLs:
- http://rheumatology.oupjournals.org ↗
http://rheumatology.oxfordjournals.org ↗
http://ukcatalogue.oup.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1093/rheumatology/keab462 ↗
- Languages:
- English
- ISSNs:
- 1462-0324
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7960.731900
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20505.xml