Post fire tensile behavior of thread-fixed one-side bolt strengthened by backing plate. (1st February 2022)
- Record Type:
- Journal Article
- Title:
- Post fire tensile behavior of thread-fixed one-side bolt strengthened by backing plate. (1st February 2022)
- Main Title:
- Post fire tensile behavior of thread-fixed one-side bolt strengthened by backing plate
- Authors:
- You, Yang
Zhu, Hao
Liu, Xinyu
Xia, Chengxin
MeiLiu,
Liu, Yuanjian
Liu, Fangzhou - Abstract:
- Highlights: Post fire behavior of Thread-fixed One-side Bolt connected T-stub was tested. Parameters including load ratio, fire temperature and backing plate were studied. The Backing Plate could improve the post fire performance of T-stub effectively. The T-stub could regain most of their tensile resistance after cooling from fire. Abstract: The post fire tensile behavior of Backing Plates (BP) strengthened Thread-fixed One-side Bolt (TOB) was studied. The full-time test method, which included the before-fire stage, firing stage and the post fire stage, was applied in the test to simulate the real fire process. Two fire temperature (500℃ and 700℃), and two load ratios (0.25 and 0.5) were tested to study the influence of fire condition to the post fire tensile behavior of TOB connected T-stub connection. The T-stubs might fail directly at firing stage at high temperature and high load ratio circumstance. The failure mode of the T-stubs also might be changed with the increase of load ratio and temperature. The post fire tensile performance of the TOB connected T-stub could be significantly increased by the BP. The residual yielding load of the T-stub strengthened by BP with 6 mm flange thickness could reach 333% to 377% to that of the un-strengthened ones with same flange thickness, and the residual ultimate load could reach 257% to 292%, depending on the fire temperature and the load ratio. T-stubs connected by Standard High Strength Bolt (SHSB) were also tested at sameHighlights: Post fire behavior of Thread-fixed One-side Bolt connected T-stub was tested. Parameters including load ratio, fire temperature and backing plate were studied. The Backing Plate could improve the post fire performance of T-stub effectively. The T-stub could regain most of their tensile resistance after cooling from fire. Abstract: The post fire tensile behavior of Backing Plates (BP) strengthened Thread-fixed One-side Bolt (TOB) was studied. The full-time test method, which included the before-fire stage, firing stage and the post fire stage, was applied in the test to simulate the real fire process. Two fire temperature (500℃ and 700℃), and two load ratios (0.25 and 0.5) were tested to study the influence of fire condition to the post fire tensile behavior of TOB connected T-stub connection. The T-stubs might fail directly at firing stage at high temperature and high load ratio circumstance. The failure mode of the T-stubs also might be changed with the increase of load ratio and temperature. The post fire tensile performance of the TOB connected T-stub could be significantly increased by the BP. The residual yielding load of the T-stub strengthened by BP with 6 mm flange thickness could reach 333% to 377% to that of the un-strengthened ones with same flange thickness, and the residual ultimate load could reach 257% to 292%, depending on the fire temperature and the load ratio. T-stubs connected by Standard High Strength Bolt (SHSB) were also tested at same conditions to calibrate the behavior of TOB. Results showed that the BP strengthened TOB connections could achieve similar post fire performance compared to the SHSB connections with flange thickness. The BP strengthened TOB connections could regain at least 88.4% of their yielding load and 88.3% of their ultimate load at ambient temperature after cooling from fire, and the residual ultimate resistance could still satisfy the design requirement, which showed the good post fire performance of TOB. … (more)
- Is Part Of:
- Engineering structures. Volume 252(2022)
- Journal:
- Engineering structures
- Issue:
- Volume 252(2022)
- Issue Display:
- Volume 252, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 252
- Issue:
- 2022
- Issue Sort Value:
- 2022-0252-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-02-01
- Subjects:
- Thread-fixed One-side Bolt -- Bolted T-stub -- Post fire -- Backing plate
TOB Thread-fixed One-side Bolt -- SHSB Standard High Strength Bolt -- BP Backing Plate
Structural engineering -- Periodicals
Structural analysis (Engineering) -- Periodicals
Construction, Technique de la -- Périodiques
Génie parasismique -- Périodiques
Pression du vent -- Périodiques
Earthquake engineering
Structural engineering
Wind-pressure
Periodicals
624.105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01410296 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engstruct.2021.113577 ↗
- Languages:
- English
- ISSNs:
- 0141-0296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3770.032000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20470.xml