478 Clinical outcomes of patients at very high stroke risk undergoing watchman implantation. (8th December 2021)
- Record Type:
- Journal Article
- Title:
- 478 Clinical outcomes of patients at very high stroke risk undergoing watchman implantation. (8th December 2021)
- Main Title:
- 478 Clinical outcomes of patients at very high stroke risk undergoing watchman implantation
- Authors:
- Magnocavallo, Michele
Rocca, Domenico Giovanni Della
Lavalle, Carlo
Carola, Gianni
Mohanty, Sa
Trivedi, Chintan
Bassiouny, Mohamed
Al-Ahmad, Amin
Burkhardt, David J
Gallinghouse, Joseph G
Sanchez, Javier E
Horton, Rodney P
Natale, Andrea
Chimenti, Cristina - Abstract:
- Abstract: Aims: Left atrial appendage occlusion (LAAO) with the Watchman device is an effective alternative to oral anticoagulation in patients with non-valvular atrial fibrillation at high thromboembolic risk. We sought to evaluate the safety and effectiveness of LAAO for stroke and bleeding prevention in patients at very high stroke risk. Methods and results: Data were extracted from a prospective database of 488 AF patients who underwent LAA closure with a Watchman device. Periprocedural complications, thromboembolic (TE), and bleeding event rates among patients with a CHA2DS2-VASc ≥ 5 were reported. Predicted annual rates of TE or major bleeding events were compared to the annualized observed risk of the population. Overall, 209 patients with a CHA2DS2-VASc ≥5 (CHA2DS2-VASc: 6.0 ± 1.0; HAS-BLED: 3.7 ± 1.1) were included in the study. The mean age was 78 ± 6 years and 52.2% ( n = 109) were males. Watchman implantation was successful in all patients. Overall procedure-related complication rate was 3.3% ( n = 7). Two major complications were observed (1.0%): one pericardial tamponade requiring surgery and one major bleeding event at 3 days post-procedure. The incidence of minor complications was 2.3% ( n = 5). Specifically, two patients experienced a pericardial effusion that required drainage and three had a groin hematoma. During a mean follow-up duration of 12 ± 5 months (193 pt/years), six TE events (2.9%/annualized rate: 3.1%) were documented after a median ofAbstract: Aims: Left atrial appendage occlusion (LAAO) with the Watchman device is an effective alternative to oral anticoagulation in patients with non-valvular atrial fibrillation at high thromboembolic risk. We sought to evaluate the safety and effectiveness of LAAO for stroke and bleeding prevention in patients at very high stroke risk. Methods and results: Data were extracted from a prospective database of 488 AF patients who underwent LAA closure with a Watchman device. Periprocedural complications, thromboembolic (TE), and bleeding event rates among patients with a CHA2DS2-VASc ≥ 5 were reported. Predicted annual rates of TE or major bleeding events were compared to the annualized observed risk of the population. Overall, 209 patients with a CHA2DS2-VASc ≥5 (CHA2DS2-VASc: 6.0 ± 1.0; HAS-BLED: 3.7 ± 1.1) were included in the study. The mean age was 78 ± 6 years and 52.2% ( n = 109) were males. Watchman implantation was successful in all patients. Overall procedure-related complication rate was 3.3% ( n = 7). Two major complications were observed (1.0%): one pericardial tamponade requiring surgery and one major bleeding event at 3 days post-procedure. The incidence of minor complications was 2.3% ( n = 5). Specifically, two patients experienced a pericardial effusion that required drainage and three had a groin hematoma. During a mean follow-up duration of 12 ± 5 months (193 pt/years), six TE events (2.9%/annualized rate: 3.1%) were documented after a median of 6.3 months (IQR: 2.2–9.6). Based on the estimated annual TE risk according to the CHA2DS2-VASc score (8.5%), the % risk reduction after LAAO was 63.5%. Four major bleeding events [1.9% (median time to event: 2.1 months; IQR: 1.0–3.4)] and five minor bleeding events occurred (2.5%) during follow-up. Compared to the expected rate of bleeding events as assessed by the HAS-BLED of the population (8.03%), LAAO led to a 42% reduction of bleeding risk. Conclusions: In a population at very high TE risk, LAAO with the Watchman device was a safe and effective approach, and led to a 63.5% of stroke risk. … (more)
- Is Part Of:
- European heart journal supplements. Volume 23(2021)Supplement G
- Journal:
- European heart journal supplements
- Issue:
- Volume 23(2021)Supplement G
- Issue Display:
- Volume 23, Issue 7 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 7
- Issue Sort Value:
- 2021-0023-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-12-08
- Subjects:
- Cardiology -- Periodicals
Cardiology -- Europe -- Periodicals
616.12005 - Journal URLs:
- http://eurheartjsupp.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/suab134.052 ↗
- Languages:
- English
- ISSNs:
- 1520-765X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717510
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20395.xml