599 Gender-based differences in TAVI outcomes: report from a large contemporary real-world population of self-expandable valves. (8th December 2021)
- Record Type:
- Journal Article
- Title:
- 599 Gender-based differences in TAVI outcomes: report from a large contemporary real-world population of self-expandable valves. (8th December 2021)
- Main Title:
- 599 Gender-based differences in TAVI outcomes: report from a large contemporary real-world population of self-expandable valves
- Authors:
- Sticchi, Alessandro
Gallo, Francesco
De Marzo, Vincenzo
Won-keun, Kim
Zeus, Tobias
Ruggiero, Rossella
Toggweiler, Stefan
De Marco, Federico
Reimers, Bernhard
Nombela-franco, Luis
Barbanti, Marco
Brugaletta, Salvatore
Piva, Tommaso
Rodes-cabau, Josep
Porto, Italo
Colombo, Antonio
Giannini, Francesco - Abstract:
- Abstract: Aims: Small sub-study data derived from randomized clinical trials suggest a gender-based disparity in TAVI outcomes. However, large real-world contemporary data is missing. The aim of this study is to compare the risk factors, procedural characteristics and clinical outcomes of male and female patients who underwent transcatheter aortic valve implantation (TAVI) using two next-generation self-expandable bioprostheses (ACURATE neo and Evolut R/Pro valves). Methods: We performed a first unmatched comparison and a propensity score-matched analysis (PSM) to assess the outcomes derived by the sex difference beyond the impact of pre-procedural risk factors in a large, contemporary, real-world, multicentre, international, retrospective registry of 3862 consecutive patients. The primary endpoint was a composite of all-cause death or any stroke (disabling and non-disabling) at 1 year. Results: Sixty-four per cent (2162/3353 patients) of the study cohort was female and was older (mean age 82.3 years vs. 81.1 years for men ( P <0.001)) had a higher BMI (27.7±5.7 for women vs. 27.2±4.5 for men), and lower prevalence of dyslipidaemia (50.2% vs. 54.7, P =0.037), diabetes (26.8% vs. 33.7, P <0.001), smoking (10.0% vs. 24.3%, P <0.001), COPD (17.4% vs. 21.9%, P =0.002), pacemaker/ICD (9.6% vs. 14.0%, P <0.001), previous cardiac surgery (8.6% vs. 18.8%, P <0.001), previous PCI (23.0% vs. 36.8%, P <0.001). Mean STS score for women was higher 5.2±3.9% vs. 4.5±3.4% ( P <0.001). WomenAbstract: Aims: Small sub-study data derived from randomized clinical trials suggest a gender-based disparity in TAVI outcomes. However, large real-world contemporary data is missing. The aim of this study is to compare the risk factors, procedural characteristics and clinical outcomes of male and female patients who underwent transcatheter aortic valve implantation (TAVI) using two next-generation self-expandable bioprostheses (ACURATE neo and Evolut R/Pro valves). Methods: We performed a first unmatched comparison and a propensity score-matched analysis (PSM) to assess the outcomes derived by the sex difference beyond the impact of pre-procedural risk factors in a large, contemporary, real-world, multicentre, international, retrospective registry of 3862 consecutive patients. The primary endpoint was a composite of all-cause death or any stroke (disabling and non-disabling) at 1 year. Results: Sixty-four per cent (2162/3353 patients) of the study cohort was female and was older (mean age 82.3 years vs. 81.1 years for men ( P <0.001)) had a higher BMI (27.7±5.7 for women vs. 27.2±4.5 for men), and lower prevalence of dyslipidaemia (50.2% vs. 54.7, P =0.037), diabetes (26.8% vs. 33.7, P <0.001), smoking (10.0% vs. 24.3%, P <0.001), COPD (17.4% vs. 21.9%, P =0.002), pacemaker/ICD (9.6% vs. 14.0%, P <0.001), previous cardiac surgery (8.6% vs. 18.8%, P <0.001), previous PCI (23.0% vs. 36.8%, P <0.001). Mean STS score for women was higher 5.2±3.9% vs. 4.5±3.4% ( P <0.001). Women had higher mean valve gradients (45.4±17.1 vs. 42.7±14.7 mmHg; P <0.001), smaller valve areas (mean 0.7 cm 2 vs. 0.9 cm 2, P =0.037) and smaller annular perimeters (56.8±23.0 vs. 62.0±23.8, P <0.001). The primary endpoint was resulted in a rate of 7.9% vs. 6.9% ( P =0.337) in the unmatched population and 9.4% vs. 6.0% ( P =0.014) after the PSM, respectively for women and for men. Independently, there was no difference in mortality (5.9% vs. 5.6%; P =0.786) and stroke (2.5% vs. 1.8%; P =0.243) rates between women and men in the un-matched groups. Rates of cardiac tamponade (1.5% vs. 0.4%, P =0.008), major vascular complications (7.7% vs. 4.1%, P <0.001), life-threatening bleeding (2.8% vs. 1.4%, P =0.016), major bleeding (5.1% vs. 2.9%, P =0.004), need of transfusion (8.9% vs. 4.6%, P <0.001) and acute kidney injury (8.5% vs. 5.7%, P =0.009), were all significantly higher in women. After PSM, mortality was similar between the two groups (11.3% for women vs. 9.5% for men, P =0.264) but strokes were more prevalent in women (2.8% vs. 1.2%, P <0.024). Furthermore, in the matched population, major vascular complications (6.8% vs. 4.1%, P =0.024), need of transfusion (9.1% vs. 4.6%, P <0.001) and acute kidney injury (8.7% vs. 5.6%, P =0.009) remained significantly different between women and men, respectively. Conclusions: In this large real-world contemporary TAVI registry, female gender was associated with higher rates of stroke, vascular complications, major bleeding, and acute kidney injury. Further studies are required to explore the underlying pathophysiological mechanisms for these observations. … (more)
- Is Part Of:
- European heart journal supplements. Volume 23(2021)Supplement G
- Journal:
- European heart journal supplements
- Issue:
- Volume 23(2021)Supplement G
- Issue Display:
- Volume 23, Issue 7 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 7
- Issue Sort Value:
- 2021-0023-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-12-08
- Subjects:
- Cardiology -- Periodicals
Cardiology -- Europe -- Periodicals
616.12005 - Journal URLs:
- http://eurheartjsupp.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/suab147.025 ↗
- Languages:
- English
- ISSNs:
- 1520-765X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717510
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20393.xml