Quality assurance in proton beam therapy using a plastic scintillator and a commercially available digital camera. (29th July 2017)
- Record Type:
- Journal Article
- Title:
- Quality assurance in proton beam therapy using a plastic scintillator and a commercially available digital camera. (29th July 2017)
- Main Title:
- Quality assurance in proton beam therapy using a plastic scintillator and a commercially available digital camera
- Authors:
- Almurayshid, Mansour
Helo, Yusuf
Kacperek, Andrzej
Griffiths, Jennifer
Hebden, Jem
Gibson, Adam - Abstract:
- Abstract: Purpose: In this article, we evaluate a plastic scintillation detector system for quality assurance in proton therapy using a BC‐408 plastic scintillator, a commercial camera, and a computer. Methods: The basic characteristics of the system were assessed in a series of proton irradiations. The reproducibility and response to changes of dose, dose‐rate, and proton energy were determined. Photographs of the scintillation light distributions were acquired, and compared with Geant4 Monte Carlo simulations and with depth‐dose curves measured with an ionization chamber. A quenching effect was observed at the Bragg peak of the 60 MeV proton beam where less light was produced than expected. We developed an approach using Birks equation to correct for this quenching. We simulated the linear energy transfer (LET) as a function of depth in Geant4 and found Birks constant by comparing the calculated LET and measured scintillation light distribution. We then used the derived value of Birks constant to correct the measured scintillation light distribution for quenching using Geant4. Results: The corrected light output from the scintillator increased linearly with dose. The system is stable and offers short‐term reproducibility to within 0.80%. No dose rate dependency was observed in this work. Conclusions: This approach offers an effective way to correct for quenching, and could provide a method for rapid, convenient, routine quality assurance for clinical proton beams.Abstract: Purpose: In this article, we evaluate a plastic scintillation detector system for quality assurance in proton therapy using a BC‐408 plastic scintillator, a commercial camera, and a computer. Methods: The basic characteristics of the system were assessed in a series of proton irradiations. The reproducibility and response to changes of dose, dose‐rate, and proton energy were determined. Photographs of the scintillation light distributions were acquired, and compared with Geant4 Monte Carlo simulations and with depth‐dose curves measured with an ionization chamber. A quenching effect was observed at the Bragg peak of the 60 MeV proton beam where less light was produced than expected. We developed an approach using Birks equation to correct for this quenching. We simulated the linear energy transfer (LET) as a function of depth in Geant4 and found Birks constant by comparing the calculated LET and measured scintillation light distribution. We then used the derived value of Birks constant to correct the measured scintillation light distribution for quenching using Geant4. Results: The corrected light output from the scintillator increased linearly with dose. The system is stable and offers short‐term reproducibility to within 0.80%. No dose rate dependency was observed in this work. Conclusions: This approach offers an effective way to correct for quenching, and could provide a method for rapid, convenient, routine quality assurance for clinical proton beams. Furthermore, the system has the advantage of providing 2D visualization of individual radiation fields, with potential application for quality assurance of complex, time‐varying fields. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 18:Number 5(2017)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 18:Number 5(2017)
- Issue Display:
- Volume 18, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 18
- Issue:
- 5
- Issue Sort Value:
- 2017-0018-0005-0000
- Page Start:
- 210
- Page End:
- 219
- Publication Date:
- 2017-07-29
- Subjects:
- proton therapy -- quality assurance -- radiotherapy
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12143 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20397.xml