Gastroesophageal varices evaluation using spleen‐dedicated stiffness measurement by vibration‐controlled transient elastography. Issue 1 (14th December 2021)
- Record Type:
- Journal Article
- Title:
- Gastroesophageal varices evaluation using spleen‐dedicated stiffness measurement by vibration‐controlled transient elastography. Issue 1 (14th December 2021)
- Main Title:
- Gastroesophageal varices evaluation using spleen‐dedicated stiffness measurement by vibration‐controlled transient elastography
- Authors:
- Nagai, Koki
Ogawa, Yuji
Kobayashi, Takashi
Iwaki, Michihiro
Nogami, Asako
Honda, Yasushi
Kessoku, Takaomi
Saigusa, Yusuke
Imajo, Kento
Yoneda, Masato
Kirikoshi, Hiroyuki
Komatsu, Tatsuji
Saito, Satoru
Nakajima, Atsushi - Abstract:
- Abstract: Background and Aim: Liver stiffness measurement (LSM) and spleen stiffness measurement (SSM@50 Hz) using standard vibration‐controlled transient elastography (VCTE) have been studied as a noninvasive test for screening of gastroesophageal varices (GEV) in chronic liver disease (CLD). Recently, a novel spleen‐dedicated VCTE (SSM@100 Hz) has been developed. We evaluated the diagnostic performance of SSM@100 Hz, SSM@50 Hz, LSM, and other noninvasive tests using esophagogastroduodenoscopy (EGD) as the reference as well as the correlation with hepatic venous pressure gradient (HVPG). Methods: A total of 123 patients with CLD enrolled in this cross‐sectional study. SSM@100 Hz, SSM@50 Hz, and LSM were determined by VCTE. EGD and HVPG were performed within 12 weeks before or after VCTE. Results: GEV were present in 60 patients. Failure or suboptimal SSM were fewer at 100 Hz (4.0%) than at 50 Hz (17.7%). All SSM values obtained at 100 Hz were lower than the 100 kPa ceiling threshold, but 10 patients reached the 75 kPa ceiling threshold for SSM@50 Hz. SSM@100 Hz was most accurate (area under the receiver operating characteristic [AUROC] = 0.944) for the diagnosis of GEV compared to SSM@50 Hz, LSM, and scoring systems. AUROC of SSM@100 Hz for diagnosis of high‐bleeding risk varices (HRV) was 0.941, which was significantly higher than that of SSM@50 Hz (AUROC = 0.842, P = 0.002). SSM@100 Hz showed higher specificity (82.0%) for diagnosis of HRV than SSM@50 HzAbstract: Background and Aim: Liver stiffness measurement (LSM) and spleen stiffness measurement (SSM@50 Hz) using standard vibration‐controlled transient elastography (VCTE) have been studied as a noninvasive test for screening of gastroesophageal varices (GEV) in chronic liver disease (CLD). Recently, a novel spleen‐dedicated VCTE (SSM@100 Hz) has been developed. We evaluated the diagnostic performance of SSM@100 Hz, SSM@50 Hz, LSM, and other noninvasive tests using esophagogastroduodenoscopy (EGD) as the reference as well as the correlation with hepatic venous pressure gradient (HVPG). Methods: A total of 123 patients with CLD enrolled in this cross‐sectional study. SSM@100 Hz, SSM@50 Hz, and LSM were determined by VCTE. EGD and HVPG were performed within 12 weeks before or after VCTE. Results: GEV were present in 60 patients. Failure or suboptimal SSM were fewer at 100 Hz (4.0%) than at 50 Hz (17.7%). All SSM values obtained at 100 Hz were lower than the 100 kPa ceiling threshold, but 10 patients reached the 75 kPa ceiling threshold for SSM@50 Hz. SSM@100 Hz was most accurate (area under the receiver operating characteristic [AUROC] = 0.944) for the diagnosis of GEV compared to SSM@50 Hz, LSM, and scoring systems. AUROC of SSM@100 Hz for diagnosis of high‐bleeding risk varices (HRV) was 0.941, which was significantly higher than that of SSM@50 Hz (AUROC = 0.842, P = 0.002). SSM@100 Hz showed higher specificity (82.0%) for diagnosis of HRV than SSM@50 Hz (specificity = 67.1%). SSM@100 Hz was significantly correlated with HVPG ( r = 0.71, P < 0.001). Conclusions: The novel spleen‐dedicated VCTE examination can be used for noninvasive assessment of GEV and HVPG in CLD. Japan Registry of Clinical Trials Registry No. jRCTs032200119. Abstract : The novel spleen‐dedicated vibration‐controlled transient elastography examination can be used for noninvasive assessment of gastroesophageal varices and hepatic venous pressure gradient in chronic liver disease. … (more)
- Is Part Of:
- JGH open. Volume 6:Issue 1(2022)
- Journal:
- JGH open
- Issue:
- Volume 6:Issue 1(2022)
- Issue Display:
- Volume 6, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 6
- Issue:
- 1
- Issue Sort Value:
- 2022-0006-0001-0000
- Page Start:
- 11
- Page End:
- 19
- Publication Date:
- 2021-12-14
- Subjects:
- gastroesophageal varices -- hepatic venous pressure gradient -- liver stiffness measurement -- portal hypertension -- spleen stiffness measurement
- Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jgh3.12689 ↗
- Languages:
- English
- ISSNs:
- 2397-9070
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20375.xml