A system for real‐time monitoring of breath‐hold via assessment of internal anatomy in tangential breast radiotherapy. Issue 1 (18th November 2021)
- Record Type:
- Journal Article
- Title:
- A system for real‐time monitoring of breath‐hold via assessment of internal anatomy in tangential breast radiotherapy. Issue 1 (18th November 2021)
- Main Title:
- A system for real‐time monitoring of breath‐hold via assessment of internal anatomy in tangential breast radiotherapy
- Authors:
- Vasina, Elena N.
Greer, Peter
Thwaites, David
Kron, Tomas
Lehmann, Joerg - Abstract:
- Abstract: The deep inspiration breath‐hold (DIBH) technique assists in sparing the heart, lungs, and liver during breast radiotherapy (RT). The quality of DIBH is currently assessed via surrogates which correlate to varying degrees with the patient's internal anatomy. Since modern linacs are equipped with an electronic portal imaging device (EPID), images of the irradiated anatomy streamed from EPIDs and analyzed in real time could significantly improve assessment of the quality of DIBH. A system has been developed to quantify the quality of DIBH during tangential breast RT by analyzing the "beam's eye view" images of the treatment fields. The system measures the lung depth (LD) and the distance from the breast surface to the posterior tangential radiation field edge (skin distance, SD) at three user‐defined locations. LD and SD measured in real time in EPID images of two RT phantoms showing different geometrical characteristics of their chest wall regions (computed tomography dose index [CTDI] and "END‐TO‐END" stereotactic body radiation therapy [E2E SBRT]) were compared with ground truth displacements provided by a precision motion platform. Performance of the new system was evaluated via static and dynamic (sine wave motion) measurements of LD and SD, covering clinical situations with stable and unstable breath‐hold. The accuracy and precision of the system were calculated as the mean and standard deviation of the differences between the ground truth and measured values.Abstract: The deep inspiration breath‐hold (DIBH) technique assists in sparing the heart, lungs, and liver during breast radiotherapy (RT). The quality of DIBH is currently assessed via surrogates which correlate to varying degrees with the patient's internal anatomy. Since modern linacs are equipped with an electronic portal imaging device (EPID), images of the irradiated anatomy streamed from EPIDs and analyzed in real time could significantly improve assessment of the quality of DIBH. A system has been developed to quantify the quality of DIBH during tangential breast RT by analyzing the "beam's eye view" images of the treatment fields. The system measures the lung depth (LD) and the distance from the breast surface to the posterior tangential radiation field edge (skin distance, SD) at three user‐defined locations. LD and SD measured in real time in EPID images of two RT phantoms showing different geometrical characteristics of their chest wall regions (computed tomography dose index [CTDI] and "END‐TO‐END" stereotactic body radiation therapy [E2E SBRT]) were compared with ground truth displacements provided by a precision motion platform. Performance of the new system was evaluated via static and dynamic (sine wave motion) measurements of LD and SD, covering clinical situations with stable and unstable breath‐hold. The accuracy and precision of the system were calculated as the mean and standard deviation of the differences between the ground truth and measured values. The accuracy of the static measurements of LD and SD for the CTDI phantom was 0.31 (1.09) mm [mean (standard deviation)] and –0.10 (0.14) mm, respectively. The accuracy of the static measurements for E2E SBRT phantom was 0.01 (0.18) mm and 0.05 (0.08) mm. The accuracy of the dynamic LD and SD measurements for the CTDI phantom was –0.50 (1.18) mm and 0.01 (0.12) mm, respectively. The accuracy of the dynamic measurements for E2E SBRT phantom was –0.03 (0.19) mm and 0.01 (0.11) mm. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 23:Issue 1(2022)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 23:Issue 1(2022)
- Issue Display:
- Volume 23, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 23
- Issue:
- 1
- Issue Sort Value:
- 2022-0023-0001-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2021-11-18
- Subjects:
- central lung distance -- deep inspiration breath‐hold (DIBH) -- EPID -- lung depth -- monitoring of internal anatomy -- real‐time portal imaging -- tangential breast radiotherapy
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13473 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20366.xml