A physiological signal compression approach using optimized Spindle Convolutional Auto-encoder in mHealth applications. (March 2022)
- Record Type:
- Journal Article
- Title:
- A physiological signal compression approach using optimized Spindle Convolutional Auto-encoder in mHealth applications. (March 2022)
- Main Title:
- A physiological signal compression approach using optimized Spindle Convolutional Auto-encoder in mHealth applications
- Authors:
- Barot, Vishal
Patel, Dr. Ritesh - Abstract:
- Highlights: A data driven approach providing energy efficient data compression. Compression Model performance validated over a PhysioNet dataset. An optimized spindle convolutional auto encoder (SCAElite) with 51.65% less computational overhead compared to conventional spindle convolutional auto encoder. Abstract: Background and Objectives: The COVID-19 pandemic manifested the need of developing robust digital platforms for facilitating healthcare services such as consultancy, clinical therapies, real time remote monitoring, early diagnosis and future predictions. Innovations made using technologies such as Internet of Things (IoT), edge computing, cloud computing and artificial intelligence are helping address this crisis. The urge for remote monitoring, symptom analysis and early detection of diseases lead to tremendous increase in the deployment of wearable sensor devices. They facilitate seamless gathering of physiological data such as electrocardiogram (ECG) signals, respiration traces (RESP), galvanic skin response (GSR), pulse rate, body temperature, photoplethysmograms (PPG), oxygen saturation (SpO2) etc. For diagnosis and analysis purpose, the gathered data needs to be stored. Wearable devices operate on batteries and have a memory constraint. In mHealth application architectures, this gathered data is hence stored on cloud based servers. While transmitting data from wearable devices to cloud servers via edge devices, a lot of energy is consumed. This paper proposesHighlights: A data driven approach providing energy efficient data compression. Compression Model performance validated over a PhysioNet dataset. An optimized spindle convolutional auto encoder (SCAElite) with 51.65% less computational overhead compared to conventional spindle convolutional auto encoder. Abstract: Background and Objectives: The COVID-19 pandemic manifested the need of developing robust digital platforms for facilitating healthcare services such as consultancy, clinical therapies, real time remote monitoring, early diagnosis and future predictions. Innovations made using technologies such as Internet of Things (IoT), edge computing, cloud computing and artificial intelligence are helping address this crisis. The urge for remote monitoring, symptom analysis and early detection of diseases lead to tremendous increase in the deployment of wearable sensor devices. They facilitate seamless gathering of physiological data such as electrocardiogram (ECG) signals, respiration traces (RESP), galvanic skin response (GSR), pulse rate, body temperature, photoplethysmograms (PPG), oxygen saturation (SpO2) etc. For diagnosis and analysis purpose, the gathered data needs to be stored. Wearable devices operate on batteries and have a memory constraint. In mHealth application architectures, this gathered data is hence stored on cloud based servers. While transmitting data from wearable devices to cloud servers via edge devices, a lot of energy is consumed. This paper proposes a deep learning based compression model SCAElite that reduces the data volume, enabling energy efficient transmission. Results: Stress Recognition in Automobile Drivers dataset and MIT-BIH dataset from PhysioNet are used for validation of algorithm performance. The model achieves a compression ratio of up to 300 fold with reconstruction errors within 8% over the stress recognition dataset and 106.34-fold with reconstruction errors within 8% over the MIT-BIH dataset. The computational complexity of SCAElite is 51.65% less compared to state-of-the-art deep compressive model. Conclusion: It is experimentally validated that SCAElite guarantees a high compression ratio with good quality restoration capabilities for physiological signal compression in mHealth applications. It has a compact architecture and is computationally more efficient compared to state-of-the-art deep compressive model. … (more)
- Is Part Of:
- Biomedical signal processing and control. Volume 73(2022)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 73(2022)
- Issue Display:
- Volume 73, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 73
- Issue:
- 2022
- Issue Sort Value:
- 2022-0073-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-03
- Subjects:
- Data compression -- Energy efficiency -- mHealth applications -- Physiological signal compression -- Spindle Convolutional Auto-encoder
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2021.103436 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20354.xml