The established and the challenger: A direct comparison of current cryoballoon technologies for pulmonary vein isolation. (18th November 2021)
- Record Type:
- Journal Article
- Title:
- The established and the challenger: A direct comparison of current cryoballoon technologies for pulmonary vein isolation. (18th November 2021)
- Main Title:
- The established and the challenger: A direct comparison of current cryoballoon technologies for pulmonary vein isolation
- Authors:
- Moser, Fabian
Rottner, Laura
Moser, Julia
Schleberger, Ruben
Lemoine, Marc
Münkler, Paula
Dinshaw, Leon
Kirchhof, Paulus
Reissmann, Bruno
Ouyang, Feifan
Rillig, Andreas
Metzner, Andreas - Abstract:
- Abstract: Introduction: Cryoballoon (CB) ablation for pulmonary vein isolation (PVI) is an effective treatment of atrial fibrillation (AF). Recently, a novel cryoablation system was introduced. The aim of the study was to compare the safety, efficacy and biophysical characteristics of a novel cryoablation system (POLARx™; Boston Scientific) to a commonly used and clinically well characterized system (Arctic Front Advance Pro™, AFA; Medtronic). Methods and Results: Fifty consecutive patients with symptomatic AF, who underwent CB‐based ablation with the POLARx were compared to 50 consecutive patients treated with the AFA. Acute PVI was achieved in 99.8% (POLARx 99.5%, AFA 100%, p = 1.00). Time to isolation (TTI) was comparable in both groups (POLARx 35 [27, 48] s, AFA 30 [21, 43] s, p = 0.165). The POLARx showed a lower balloon temperature at TTI (POLARx −44 [−50, −36] °C, AFA −31 [−38, −21] °C, p < 0.001) and lower nadir temperature (POLARx −60 [−65, −55] °C, AFA −48 [−54, −45] °C, p < 0.001). Procedure time (POLARx 80 [60, 105] min, AFA 62 [42, 80] min, p < 0.001), fluoroscopy time (POLARx 17 [13, 22] min, AFA 11 [7, 16] min, p < 0.001) and freeze cycles per patient (POLARx 5 [4, 6], AFA 4.5 [4, 5], p = 0.002) were higher in the POLARx group. Two cerebral ischemic events occurred in the POLARx group, two patients in each group had phrenic nerve injury. Conclusion: Both systems enable effective isolation of pulmonary veins. The POLARx required longer procedure andAbstract: Introduction: Cryoballoon (CB) ablation for pulmonary vein isolation (PVI) is an effective treatment of atrial fibrillation (AF). Recently, a novel cryoablation system was introduced. The aim of the study was to compare the safety, efficacy and biophysical characteristics of a novel cryoablation system (POLARx™; Boston Scientific) to a commonly used and clinically well characterized system (Arctic Front Advance Pro™, AFA; Medtronic). Methods and Results: Fifty consecutive patients with symptomatic AF, who underwent CB‐based ablation with the POLARx were compared to 50 consecutive patients treated with the AFA. Acute PVI was achieved in 99.8% (POLARx 99.5%, AFA 100%, p = 1.00). Time to isolation (TTI) was comparable in both groups (POLARx 35 [27, 48] s, AFA 30 [21, 43] s, p = 0.165). The POLARx showed a lower balloon temperature at TTI (POLARx −44 [−50, −36] °C, AFA −31 [−38, −21] °C, p < 0.001) and lower nadir temperature (POLARx −60 [−65, −55] °C, AFA −48 [−54, −45] °C, p < 0.001). Procedure time (POLARx 80 [60, 105] min, AFA 62 [42, 80] min, p < 0.001), fluoroscopy time (POLARx 17 [13, 22] min, AFA 11 [7, 16] min, p < 0.001) and freeze cycles per patient (POLARx 5 [4, 6], AFA 4.5 [4, 5], p = 0.002) were higher in the POLARx group. Two cerebral ischemic events occurred in the POLARx group, two patients in each group had phrenic nerve injury. Conclusion: Both systems enable effective isolation of pulmonary veins. The POLARx required longer procedure and fluoroscopy times. Larger, prospective and randomized studies are needed to assess long‐term efficacy and safety of this technology. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 33:Number 1(2022)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 33:Number 1(2022)
- Issue Display:
- Volume 33, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 33
- Issue:
- 1
- Issue Sort Value:
- 2022-0033-0001-0000
- Page Start:
- 48
- Page End:
- 54
- Publication Date:
- 2021-11-18
- Subjects:
- atrial fibrillation -- catheter ablation -- cryoballoon technology -- pulmonary vein isolation
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.15288 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20328.xml