Contrast-enhanced ultrasound is a reliable and reproducible assessment of necrotic ablated volume after radiofrequency ablation for benign thyroid nodules: a retrospective study. (1st January 2022)
- Record Type:
- Journal Article
- Title:
- Contrast-enhanced ultrasound is a reliable and reproducible assessment of necrotic ablated volume after radiofrequency ablation for benign thyroid nodules: a retrospective study. (1st January 2022)
- Main Title:
- Contrast-enhanced ultrasound is a reliable and reproducible assessment of necrotic ablated volume after radiofrequency ablation for benign thyroid nodules: a retrospective study
- Authors:
- Yan, Lin
Li, XinYang
Xiao, Jing
Li, YingYing
Zhu, Yaqiong
He, Hongying
Luo, Yukun - Abstract:
- Abstract: Purpose: To investigate the intra- and inter-observer reliability and agreement of contrast-enhanced ultrasound (CEUS) in measuring ablated volume (Va) after radiofrequency ablation (RFA) for benign thyroid nodules. Materials: This retrospective study evaluated 65 patients with 74 benign thyroid nodules who underwent RFA. Patients were followed up at 1, 3, 6, and 12 months and every 12 months thereafter. Two independent observers measured the Va using CEUS during the same follow-up visit. The intra- and inter-observer reliability was assessed using intraclass correlation coefficient (ICC) with 95% confidence interval. The Bland–Altman analysis was used to evaluate the inter-observer agreement, which was expressed as a mean difference with 95% limit of agreement (LOA). Results: No significant difference was found in Va measurements by the two observers with a mean follow-up time of 41.17 ± 16.80 months (all p > 0.05). The intra- and inter-observer reliability were both excellent (ICC >0.90) at each follow-up period. The 95% LOA became wider over the follow-up period. The smallest 95% LOA was found at 1 month with a LOA from 0.8117 to 1.122, and the largest 95% LOA was from 0.5694 to 1.343 at 36 months. Conclusions: CEUS could provide a reliable and reproducible assessment of Va after RFA for benign thyroid nodules. In clinical post-ablation follow-up, the irregular morphology of ablated area and the variation by different observers could not affect the assessmentAbstract: Purpose: To investigate the intra- and inter-observer reliability and agreement of contrast-enhanced ultrasound (CEUS) in measuring ablated volume (Va) after radiofrequency ablation (RFA) for benign thyroid nodules. Materials: This retrospective study evaluated 65 patients with 74 benign thyroid nodules who underwent RFA. Patients were followed up at 1, 3, 6, and 12 months and every 12 months thereafter. Two independent observers measured the Va using CEUS during the same follow-up visit. The intra- and inter-observer reliability was assessed using intraclass correlation coefficient (ICC) with 95% confidence interval. The Bland–Altman analysis was used to evaluate the inter-observer agreement, which was expressed as a mean difference with 95% limit of agreement (LOA). Results: No significant difference was found in Va measurements by the two observers with a mean follow-up time of 41.17 ± 16.80 months (all p > 0.05). The intra- and inter-observer reliability were both excellent (ICC >0.90) at each follow-up period. The 95% LOA became wider over the follow-up period. The smallest 95% LOA was found at 1 month with a LOA from 0.8117 to 1.122, and the largest 95% LOA was from 0.5694 to 1.343 at 36 months. Conclusions: CEUS could provide a reliable and reproducible assessment of Va after RFA for benign thyroid nodules. In clinical post-ablation follow-up, the irregular morphology of ablated area and the variation by different observers could not affect the assessment of Va by CEUS. … (more)
- Is Part Of:
- International journal of hyperthermia. Volume 39:Number 1(2022)
- Journal:
- International journal of hyperthermia
- Issue:
- Volume 39:Number 1(2022)
- Issue Display:
- Volume 39, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 39
- Issue:
- 1
- Issue Sort Value:
- 2022-0039-0001-0000
- Page Start:
- 40
- Page End:
- 47
- Publication Date:
- 2022-01-01
- Subjects:
- Radiofrequency ablation -- thyroid nodule -- ultrasonography -- reproducibility of results -- ablation techniques
Thermotherapy -- Periodicals
615.832 - Journal URLs:
- http://informahealthcare.com/loi/hth ↗
http://www.tandf.co.uk/journals/titles/02656736.asp ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/02656736.2021.1991009 ↗
- Languages:
- English
- ISSNs:
- 0265-6736
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.297000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20305.xml