FUNCTIONAL AND MORPHOLOGICAL OUTCOMES OF THE INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE IN SMALL-SIZED AND MEDIUM-SIZED MACULAR HOLES <400 µm. Issue 10 (October 2021)
- Record Type:
- Journal Article
- Title:
- FUNCTIONAL AND MORPHOLOGICAL OUTCOMES OF THE INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE IN SMALL-SIZED AND MEDIUM-SIZED MACULAR HOLES <400 µm. Issue 10 (October 2021)
- Main Title:
- FUNCTIONAL AND MORPHOLOGICAL OUTCOMES OF THE INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE IN SMALL-SIZED AND MEDIUM-SIZED MACULAR HOLES <400 µm
- Authors:
- Baumann, Carmen
Dervenis, Nikolaos
Kirchmair, Katharina
Lohmann, Chris P.
Kaye, Stephen B.
Sandinha, Maria T. - Abstract:
- Abstract : Purpose: To assess the effect of an internal limiting membrane flap (IF) in macular hole surgery on the best-corrected visual acuity (BCVA) and integrity of the ellipsoid zone (EZ) and external limiting membrane. Methods: Patients were included who had successful surgery for macular hole <400 µ m with or without an IF. Main outcome measures were BCVA and restoration of the external limiting membrane and EZ at 12 months. Results: Sixty patients were included, 36 with conventional peeling and 24 with an IF. The best-corrected visual acuity improved from 0.74 (±0.30) logarithm of the minimum angle of resolution (20/110 Snellen) to 0.26 (±0.20) (20/36 Snellen) in patients without and from 0.77 (±0.32) logarithm of the minimum angle of resolution (20/118 Snellen) to 0.18 (±0.12) (20/30 Snellen) in patients with an IF, respectively. There was no difference in the integrity of the EZ and external limiting membrane in patients with or without an IF at either 3 ( P = 0.58, P = 0.20), 6 ( P = 0.81, P = 0.10), or 12 months ( P = 0.60, P = 0.20) or in the BCVA at 3 ( P = 0.24), 6 ( P = 0.18) and 12 months ( P = 0.11). In the multivariable model, only preoperative BCVA ( P < 0.01), EZ integrity ( P = 0.001), and age ( P < 0.01) were associated with the post-operative BCVA. Conclusion: In patients undergoing surgery for macular hole <400 µ m, the use of an IF did not affect the BCVA or the integrity of the EZ and external limiting membrane. Abstract : After surgery for macularAbstract : Purpose: To assess the effect of an internal limiting membrane flap (IF) in macular hole surgery on the best-corrected visual acuity (BCVA) and integrity of the ellipsoid zone (EZ) and external limiting membrane. Methods: Patients were included who had successful surgery for macular hole <400 µ m with or without an IF. Main outcome measures were BCVA and restoration of the external limiting membrane and EZ at 12 months. Results: Sixty patients were included, 36 with conventional peeling and 24 with an IF. The best-corrected visual acuity improved from 0.74 (±0.30) logarithm of the minimum angle of resolution (20/110 Snellen) to 0.26 (±0.20) (20/36 Snellen) in patients without and from 0.77 (±0.32) logarithm of the minimum angle of resolution (20/118 Snellen) to 0.18 (±0.12) (20/30 Snellen) in patients with an IF, respectively. There was no difference in the integrity of the EZ and external limiting membrane in patients with or without an IF at either 3 ( P = 0.58, P = 0.20), 6 ( P = 0.81, P = 0.10), or 12 months ( P = 0.60, P = 0.20) or in the BCVA at 3 ( P = 0.24), 6 ( P = 0.18) and 12 months ( P = 0.11). In the multivariable model, only preoperative BCVA ( P < 0.01), EZ integrity ( P = 0.001), and age ( P < 0.01) were associated with the post-operative BCVA. Conclusion: In patients undergoing surgery for macular hole <400 µ m, the use of an IF did not affect the BCVA or the integrity of the EZ and external limiting membrane. Abstract : After surgery for macular holes <400 µ m, the best-corrected visual acuity and the integrity of the ellipsoid zone improved significantly between 3 and 12 months, irrespective of the use of an internal limiting membrane flap. … (more)
- Is Part Of:
- Retina. Volume 41:Issue 10(2021)
- Journal:
- Retina
- Issue:
- Volume 41:Issue 10(2021)
- Issue Display:
- Volume 41, Issue 10 (2021)
- Year:
- 2021
- Volume:
- 41
- Issue:
- 10
- Issue Sort Value:
- 2021-0041-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10
- Subjects:
- effect of ILM flap on BCVA -- ELM and EZ
Retina -- Diseases -- Periodicals
Retinal Diseases
Vitreous Body
617.735 - Journal URLs:
- http://journals.lww.com/retinajournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IAE.0000000000003160 ↗
- Languages:
- English
- ISSNs:
- 0275-004X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7785.510300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20266.xml