Clinical Value of Stress Transaortic Flow Rate During Dobutamine Echocardiography in Reduced Left Ventricular Ejection Fraction, Low-Gradient Aortic Stenosis: A Multicenter Study. (November 2021)
- Record Type:
- Journal Article
- Title:
- Clinical Value of Stress Transaortic Flow Rate During Dobutamine Echocardiography in Reduced Left Ventricular Ejection Fraction, Low-Gradient Aortic Stenosis: A Multicenter Study. (November 2021)
- Main Title:
- Clinical Value of Stress Transaortic Flow Rate During Dobutamine Echocardiography in Reduced Left Ventricular Ejection Fraction, Low-Gradient Aortic Stenosis
- Authors:
- Vamvakidou, Anastasia
Annabi, Mohamed-Salah
Pibarot, Phillipe
Plonska-Gosciniak, Edyta
Almeida, Ana G.
Guzzetti, Ezequiel
Dahou, Abdellaziz
Burwash, Ian G.
Koschutnik, Matthias
Bartko, Philipp E.
Bergler-Klein, Jutta
Mascherbauer, Julia
Orwat, Stefan
Baumgartner, Helmut
Cavalcante, Joao
Pinto, Fausto
Kukulski, Tomasz
Kasprzak, Jaroslaw D.
Clavel, Marie-Annick
Flachskampf, Frank A.
Senior, Roxy - Abstract:
- Abstract : Background: Low rest transaortic flow rate (FR) has been shown previously to predict mortality in low-gradient aortic stenosis. However limited prognostic data exists on stress FR during low-dose dobutamine stress echocardiography. We aimed to assess the value of stress FR for the detection of aortic valve stenosis (AS) severity and the prediction of mortality. Methods: This is a multicenter cohort study of patients with reduced left ventricular ejection fraction and low-gradient aortic stenosis (aortic valve area <1 cm 2 and mean gradient <40 mm Hg) who underwent low-dose dobutamine stress echocardiography to identify the AS severity and presence of flow reserve. The outcome assessed was all-cause mortality. Results: Of the 287 patients (mean age, 75±10 years; males, 71%; left ventricular ejection fraction, 31±10%) over a mean follow-up of 24±30 months there were 127 (44.3%) deaths and 147 (51.2%) patients underwent aortic valve intervention. Higher stress FR was independently associated with reduced risk of mortality (hazard ratio, 0.97 [95% CI, 0.94–0.99]; P =0.01) after adjusting for age, chronic kidney disease, heart failure symptoms, aortic valve intervention, and rest left ventricular ejection fraction. The minimum cutoff for prediction of mortality was stress FR 210 mL/s. Following adjustment to the same important clinical and echocardiographic parameters, among the three criteria of AS severity during stress, ie, the guideline definition of aortic valveAbstract : Background: Low rest transaortic flow rate (FR) has been shown previously to predict mortality in low-gradient aortic stenosis. However limited prognostic data exists on stress FR during low-dose dobutamine stress echocardiography. We aimed to assess the value of stress FR for the detection of aortic valve stenosis (AS) severity and the prediction of mortality. Methods: This is a multicenter cohort study of patients with reduced left ventricular ejection fraction and low-gradient aortic stenosis (aortic valve area <1 cm 2 and mean gradient <40 mm Hg) who underwent low-dose dobutamine stress echocardiography to identify the AS severity and presence of flow reserve. The outcome assessed was all-cause mortality. Results: Of the 287 patients (mean age, 75±10 years; males, 71%; left ventricular ejection fraction, 31±10%) over a mean follow-up of 24±30 months there were 127 (44.3%) deaths and 147 (51.2%) patients underwent aortic valve intervention. Higher stress FR was independently associated with reduced risk of mortality (hazard ratio, 0.97 [95% CI, 0.94–0.99]; P =0.01) after adjusting for age, chronic kidney disease, heart failure symptoms, aortic valve intervention, and rest left ventricular ejection fraction. The minimum cutoff for prediction of mortality was stress FR 210 mL/s. Following adjustment to the same important clinical and echocardiographic parameters, among the three criteria of AS severity during stress, ie, the guideline definition of aortic valve area <1cm 2 and aortic valve mean gradient ≥40 mm Hg, or aortic valve mean gradient ≥40 mm Hg, or the novel definition of aortic valve area <1 cm 2 at stress FR ≥210 mL/s, only the latter was independently associated with mortality (hazard ratio, 1.72 [95% CI, 1.05–2.82]; P =0.03). Furthermore aortic valve area <1cm 2 at stress FR ≥210 mL/s was the only severe aortic stenosis criterion that was associated with improved outcome following aortic valve intervention ( P <0.001). Guideline-defined stroke volume flow reserve did not predict mortality. Conclusions: Stress FR during low-dose dobutamine stress echocardiography was useful for the detection of both AS severity and flow reserve and was associated with improved prediction of outcome following aortic valve intervention. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 14:Number 11(2021)
- Journal:
- Circulation
- Issue:
- Volume 14:Number 11(2021)
- Issue Display:
- Volume 14, Issue 11 (2021)
- Year:
- 2021
- Volume:
- 14
- Issue:
- 11
- Issue Sort Value:
- 2021-0014-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-11
- Subjects:
- cohort studies -- echocardiography, stress -- heart failure -- prognosis -- stroke volume
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.1075405 - Journal URLs:
- http://circimaging.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCIMAGING.121.012809 ↗
- Languages:
- English
- ISSNs:
- 1941-9651
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262750
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20261.xml