CT Hypoperfusion-Hypodensity Mismatch to Identify Patients With Acute Ischemic Stroke Within 4.5 Hours of Symptom Onset. (23rd November 2021)
- Record Type:
- Journal Article
- Title:
- CT Hypoperfusion-Hypodensity Mismatch to Identify Patients With Acute Ischemic Stroke Within 4.5 Hours of Symptom Onset. (23rd November 2021)
- Main Title:
- CT Hypoperfusion-Hypodensity Mismatch to Identify Patients With Acute Ischemic Stroke Within 4.5 Hours of Symptom Onset
- Authors:
- Sporns, Peter B.
Kemmling, André
Minnerup, Heike
Meyer, Lennart
Krogias, Christos
Puetz, Volker
Thierfelder, Kolja
Duering, Marco
Kaiser, Daniel
Langner, Soenke
Massoth, Christina
Brehm, Alex
Rotkopf, Lukas
Kunz, Wolfgang G.
Karch, André
Fiehler, Jens
Heindel, Walter
Schramm, Peter
Royl, Georg
Wiendl, Heinz
Psychogios, Marios
Minnerup, Jens - Abstract:
- Abstract : Background and Objectives: To test the hypothesis that CT hypoperfusion-hypodensity mismatch identifies patients with ischemic stroke within 4.5 hours of symptom onset. Methods: We therefore performed the Retrospective Multicenter Hypoperfusion-Hypodensity Mismatch for The identification of Patients With Stroke Within 4.5 Hours study of patients with acute ischemic stroke and known time of symptom onset. The predictive values of hypoperfusion-hypodensity mismatch for the identification of patients with symptom onset within 4.5 hours were the main outcome measure. Results: Of 666 patients, 548 (82.3%) had multimodal CT within 4.5 hours and 118 (17.7%) beyond 4.5 hours. Hypoperfusion-hypodensity mismatch was visible in 516 (94.2%) patients with symptom onset within and in 30 (25.4%) patients beyond 4.5 hours. CT hypoperfusion-hypodensity mismatch identified patients within 4.5 hours of stroke onset with 94.2% (95% confidence interval [CI] 91.9%–95.8%) sensitivity, 74.6% (95% CI 66.0%–81.6%) specificity, 94.5% (95% CI 92.3%–96.1%) positive predictive value, and 73.3% (95% CI 64.8%–80.4%) negative predictive value. Interobserver agreement for hypoperfusion-hypodensity mismatch was substantial (κ = 0.61, 95% CI 0.53–0.69). Discussion: Patients with acute ischemic stroke with absence of a hypodensity on native CT (NCCT) within the hypoperfused core lesion on perfusion CT (hypoperfusion-hypodensity mismatch) are likely to be within the time window of thrombolysis.Abstract : Background and Objectives: To test the hypothesis that CT hypoperfusion-hypodensity mismatch identifies patients with ischemic stroke within 4.5 hours of symptom onset. Methods: We therefore performed the Retrospective Multicenter Hypoperfusion-Hypodensity Mismatch for The identification of Patients With Stroke Within 4.5 Hours study of patients with acute ischemic stroke and known time of symptom onset. The predictive values of hypoperfusion-hypodensity mismatch for the identification of patients with symptom onset within 4.5 hours were the main outcome measure. Results: Of 666 patients, 548 (82.3%) had multimodal CT within 4.5 hours and 118 (17.7%) beyond 4.5 hours. Hypoperfusion-hypodensity mismatch was visible in 516 (94.2%) patients with symptom onset within and in 30 (25.4%) patients beyond 4.5 hours. CT hypoperfusion-hypodensity mismatch identified patients within 4.5 hours of stroke onset with 94.2% (95% confidence interval [CI] 91.9%–95.8%) sensitivity, 74.6% (95% CI 66.0%–81.6%) specificity, 94.5% (95% CI 92.3%–96.1%) positive predictive value, and 73.3% (95% CI 64.8%–80.4%) negative predictive value. Interobserver agreement for hypoperfusion-hypodensity mismatch was substantial (κ = 0.61, 95% CI 0.53–0.69). Discussion: Patients with acute ischemic stroke with absence of a hypodensity on native CT (NCCT) within the hypoperfused core lesion on perfusion CT (hypoperfusion-hypodensity mismatch) are likely to be within the time window of thrombolysis. Applying this method may guide the decision to use thrombolysis in patients with unknown time of stroke onset. Trial Registration Information: ClinicalTrials.gov Identifier: NCT04277728. Classification of Evidence: This study provides Class III evidence that CT hypoperfusion-hypodensity mismatch identifies patients with stroke within 4.5 hours of onset. … (more)
- Is Part Of:
- Neurology. Volume 97:Number 21(2021)
- Journal:
- Neurology
- Issue:
- Volume 97:Number 21(2021)
- Issue Display:
- Volume 97, Issue 21 (2021)
- Year:
- 2021
- Volume:
- 97
- Issue:
- 21
- Issue Sort Value:
- 2021-0097-0021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-11-23
- Subjects:
- Neurology -- Periodicals
Neurology -- Periodicals
Neurologie -- Périodiques
616.8 - Journal URLs:
- http://www.mdconsult.com/public/search?search_type=journal&j_sort=pub_date&j_issn=0028-3878 ↗
http://www.mdconsult.com/about/journallist/192093418-5/about0nz0.html ↗
http://www.neurology.org ↗
http://journals.lww.com ↗ - DOI:
- 10.1212/WNL.0000000000012891 ↗
- Languages:
- English
- ISSNs:
- 0028-3878
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.500000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20264.xml