Multiaxial pulsatile dynamics of the thoracic aorta and impact of thoracic endovascular repair. (2021)
- Record Type:
- Journal Article
- Title:
- Multiaxial pulsatile dynamics of the thoracic aorta and impact of thoracic endovascular repair. (2021)
- Main Title:
- Multiaxial pulsatile dynamics of the thoracic aorta and impact of thoracic endovascular repair
- Authors:
- Suh, Ga-Young
Bondesson, Johan
Zhu, Yufei D.
Lee, Jason T.
Dake, Michael D.
Cheng, Christopher P. - Abstract:
- Highlights: Altered motion of the thoracic aorta after thoracic endovascular aortic repair. Geometric analysis with cardiac-gated computed tomography and computer modeling. Decreased motion of the stented aorta and increased motion above the stented aorta. Longitudinal curvature and diametric deformation affected by presence of endograft. Abstract: Purpose: The thoracic aorta is a highly mobile organ whose dynamics are altered by thoracic endovascular aorta repair (TEVAR). The aim of this study was to quantify cardiac pulsatility-induced multi-axial deformation of the thoracic aorta before and after descending aortic TEVAR. Methods: Eleven TEVAR patients (8 males and 3 females, age 57–89) underwent retrospective cardiac-gated CT angiography before and after TEVAR. 3D geometric models of the thoracic aorta were constructed, and lumen centerlines, inner and outer surface curves, and cross-sections were extracted to measure aortic arclength, centerline, inner surface, and outer surface longitudinal curvatures, as well as cross-sectional effective diameter and eccentricity for the ascending and stented aortic portions. Results: From pre- to post-TEVAR, arclength deformation was increased at the ascending aorta from 5.9 ± 3.1 % to 8.8 ± 4.4 % (P < 0.05), and decreased at the stented aorta from 7.5 ± 5.1 % to 2.7 ± 2.5 % (P < 0.05). Longitudinal curvature and diametric deformations were reduced at the stented aorta. Centerline curvature, inner surface curvature, andHighlights: Altered motion of the thoracic aorta after thoracic endovascular aortic repair. Geometric analysis with cardiac-gated computed tomography and computer modeling. Decreased motion of the stented aorta and increased motion above the stented aorta. Longitudinal curvature and diametric deformation affected by presence of endograft. Abstract: Purpose: The thoracic aorta is a highly mobile organ whose dynamics are altered by thoracic endovascular aorta repair (TEVAR). The aim of this study was to quantify cardiac pulsatility-induced multi-axial deformation of the thoracic aorta before and after descending aortic TEVAR. Methods: Eleven TEVAR patients (8 males and 3 females, age 57–89) underwent retrospective cardiac-gated CT angiography before and after TEVAR. 3D geometric models of the thoracic aorta were constructed, and lumen centerlines, inner and outer surface curves, and cross-sections were extracted to measure aortic arclength, centerline, inner surface, and outer surface longitudinal curvatures, as well as cross-sectional effective diameter and eccentricity for the ascending and stented aortic portions. Results: From pre- to post-TEVAR, arclength deformation was increased at the ascending aorta from 5.9 ± 3.1 % to 8.8 ± 4.4 % (P < 0.05), and decreased at the stented aorta from 7.5 ± 5.1 % to 2.7 ± 2.5 % (P < 0.05). Longitudinal curvature and diametric deformations were reduced at the stented aorta. Centerline curvature, inner surface curvature, and cross-sectional eccentricity deformations were increased at the distal ascending aorta. Conclusions: Deformations were reduced in the stented thoracic aorta after TEVAR, but increased in the ascending aorta near the aortic arch, possibly as a compensatory mechanism to maintain overall thoracic compliance in the presence of reduced deformation in the stiffened stented aorta. … (more)
- Is Part Of:
- European journal of radiology open. Volume 8(2021)
- Journal:
- European journal of radiology open
- Issue:
- Volume 8(2021)
- Issue Display:
- Volume 8, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 8
- Issue:
- 2021
- Issue Sort Value:
- 2021-0008-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021
- Subjects:
- TEVAR thoracic endovascular aortic repair -- 3D three-dimensional -- 2D two-dimensional -- CTA computed tomography angiography
TEVAR -- Thoracic aorta -- Deformation -- Cardiac pulsatility -- Aortic dissection -- Aortic aneurysm
Medical radiology -- Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23520477/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.ejro.2021.100333 ↗
- Languages:
- English
- ISSNs:
- 2352-0477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20262.xml