Refrigerant maldistribution in brazed plate heat exchanger evaporators. Part A: Testing campaign and experimental results. (November 2021)
- Record Type:
- Journal Article
- Title:
- Refrigerant maldistribution in brazed plate heat exchanger evaporators. Part A: Testing campaign and experimental results. (November 2021)
- Main Title:
- Refrigerant maldistribution in brazed plate heat exchanger evaporators. Part A: Testing campaign and experimental results
- Authors:
- Navarro-Peris, Emilio
Alvarez-Piñeiro, Lucas
Albaladejo, Paloma
Schnabel, Lena
Corberan, Jose M - Abstract:
- Highlights: Thermography is a reliable technic to evaluate refrigerant maldistribution in Brazed Plate evaporators. Evaluation of refrigerant maldistribution at different evaporator working conditions. Conditions with 0 superheat show a uniform thermal map. The rest of the conditions have shown some degree of thermal maldistribution. The effect of the maldistribution on the evaporator performance depends on the working conditions. Abstract: The refrigerant distribution in a brazed plate heat exchanger evaporator with distributor has been studied with a thermographic camera working under different conditions of inlet vapor quality, superheat, and water temperature drop. The thermographies have shown a clear uneven thermal distribution except when superheat is null. In most of the cases, they show that a great part of the liquid accumulates at the end channels of the evaporator. The degradation of the evaporator performance is higher when the water temperature drop has a similar or higher value than the superheat. On the other hand, when the superheat is significantly higher than the water temperature drop, the evaporator performance is very similar to situations in which there is an even distribution of the refrigerant. The registered evaporation temperatures are much lower for the case of 13 K of water temperature drop, highlighting the importance of the influence of this parameter on the evaporator performance. This research is described in two parts, Part A (present paper)Highlights: Thermography is a reliable technic to evaluate refrigerant maldistribution in Brazed Plate evaporators. Evaluation of refrigerant maldistribution at different evaporator working conditions. Conditions with 0 superheat show a uniform thermal map. The rest of the conditions have shown some degree of thermal maldistribution. The effect of the maldistribution on the evaporator performance depends on the working conditions. Abstract: The refrigerant distribution in a brazed plate heat exchanger evaporator with distributor has been studied with a thermographic camera working under different conditions of inlet vapor quality, superheat, and water temperature drop. The thermographies have shown a clear uneven thermal distribution except when superheat is null. In most of the cases, they show that a great part of the liquid accumulates at the end channels of the evaporator. The degradation of the evaporator performance is higher when the water temperature drop has a similar or higher value than the superheat. On the other hand, when the superheat is significantly higher than the water temperature drop, the evaporator performance is very similar to situations in which there is an even distribution of the refrigerant. The registered evaporation temperatures are much lower for the case of 13 K of water temperature drop, highlighting the importance of the influence of this parameter on the evaporator performance. This research is described in two parts, Part A (present paper) including the description of the experimental campaign, the obtained experimental results and the results discussion and Part B including an analysis of the degradation of the evaporation temperature due to the refrigerant maldistribution as well as a deeper analysis of the registered temperatures and of the causes for the great degradation observed when the water temperature drop is increased. … (more)
- Is Part Of:
- International journal of refrigeration. Volume 131(2021)
- Journal:
- International journal of refrigeration
- Issue:
- Volume 131(2021)
- Issue Display:
- Volume 131, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 131
- Issue:
- 2021
- Issue Sort Value:
- 2021-0131-2021-0000
- Page Start:
- 119
- Page End:
- 128
- Publication Date:
- 2021-11
- Subjects:
- Brazed plate heat exchanger -- Evaporator -- Refrigerant maldistribution -- Efficiency
Échangeur à plaques brasées -- Évaporateur -- Mauvaise distribution du frigorigène -- Rendement
Refrigeration and refrigerating machinery -- Periodicals
621.56 - Journal URLs:
- http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science/journal/aip/01407007 ↗ - DOI:
- 10.1016/j.ijrefrig.2021.04.002 ↗
- Languages:
- English
- ISSNs:
- 0140-7007
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.525500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20268.xml