Simplified patient-specific renal dosimetry in 177Lu therapy: a proof of concept. (December 2021)
- Record Type:
- Journal Article
- Title:
- Simplified patient-specific renal dosimetry in 177Lu therapy: a proof of concept. (December 2021)
- Main Title:
- Simplified patient-specific renal dosimetry in 177Lu therapy: a proof of concept
- Authors:
- Ligonnet, Thomas
Pistone, Daniele
Auditore, Lucrezia
Italiano, Antonio
Amato, Ernesto
Campennì, Alfredo
Schaefer, Niklaus
Boughdad, Sarah
Baldari, Sergio
Gnesin, Silvano - Abstract:
- Highlights: Simplified renal dosimetry in 177Lu-PRRT using one SPECT-CT and probe measurements. Proof-of-concept use on experimental phantom and Monte Carlo. Dosimetric method successfully tested on patient images. Abstract: Purpose: The aim of this proof-of-concept study is to propose a simplified personalized kidney dosimetry procedure in 177 Lu peptide receptor radionuclide therapy (PRRT) for neuroendocrine tumors and metastatic prostate cancer. It relies on a single quantitative SPECT/CT acquisition and multiple radiometric measurements executed with a collimated external probe, properly directed on kidneys. Methods: We conducted a phantom study involving external count-rate measurements in an abdominal phantom setup filled with activity concentrations of 99m Tc, reproducing patient-relevant organ effective half-lives occurring in 177 Lu PRRT. GATE Monte Carlo (MC) simulations of the experiment, using 99m Tc and 177 Lu as sources, were performed. Furthermore, we tested this method via MC on a clinical case of 177 Lu-DOTATATE PRRT with SPECT/CT images at three time points (2, 20 and 70 hrs), comparing a simplified kidney dosimetry, employing a single SPECT/CT and probe measurements at three time points, with the complete MC dosimetry. Results: The experimentally estimated kidney half-life with background subtraction applied was compatible within 3% with the expected value. The MC simulations of the phantom study, both with 99m Tc and 177 Lu, confirmed a similar level ofHighlights: Simplified renal dosimetry in 177Lu-PRRT using one SPECT-CT and probe measurements. Proof-of-concept use on experimental phantom and Monte Carlo. Dosimetric method successfully tested on patient images. Abstract: Purpose: The aim of this proof-of-concept study is to propose a simplified personalized kidney dosimetry procedure in 177 Lu peptide receptor radionuclide therapy (PRRT) for neuroendocrine tumors and metastatic prostate cancer. It relies on a single quantitative SPECT/CT acquisition and multiple radiometric measurements executed with a collimated external probe, properly directed on kidneys. Methods: We conducted a phantom study involving external count-rate measurements in an abdominal phantom setup filled with activity concentrations of 99m Tc, reproducing patient-relevant organ effective half-lives occurring in 177 Lu PRRT. GATE Monte Carlo (MC) simulations of the experiment, using 99m Tc and 177 Lu as sources, were performed. Furthermore, we tested this method via MC on a clinical case of 177 Lu-DOTATATE PRRT with SPECT/CT images at three time points (2, 20 and 70 hrs), comparing a simplified kidney dosimetry, employing a single SPECT/CT and probe measurements at three time points, with the complete MC dosimetry. Results: The experimentally estimated kidney half-life with background subtraction applied was compatible within 3% with the expected value. The MC simulations of the phantom study, both with 99m Tc and 177 Lu, confirmed a similar level of accuracy. Concerning the clinical case, the simplified dosimetric method led to a kidney dose estimation compatible with the complete MC dosimetry within 6%, 12% and 2%, using respectively the SPECT/CT at 2, 20 and 70 hrs. Conclusions: The proposed simplified procedure provided a satisfactory accuracy and would reduce the imaging required to derive the kidney absorbed dose to a unique quantitative SPECT/CT, with consequent benefits in terms of clinic workflows and patient comfort. … (more)
- Is Part Of:
- Physica medica. Volume 92(2021)
- Journal:
- Physica medica
- Issue:
- Volume 92(2021)
- Issue Display:
- Volume 92, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 92
- Issue:
- 2021
- Issue Sort Value:
- 2021-0092-2021-0000
- Page Start:
- 75
- Page End:
- 85
- Publication Date:
- 2021-12
- Subjects:
- Internal dosimetry -- Monte Carlo -- PRRT -- Kidney -- 177Lu
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2021.11.007 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20210.xml