Evaluating cut‐off levels for progesterone, β human chorionic gonadotropin and β human chorionic gonadotropin ratio to exclude pregnancy viability in women with a pregnancy of unknown location: A prospective multicenter cohort study. (24th November 2021)
- Record Type:
- Journal Article
- Title:
- Evaluating cut‐off levels for progesterone, β human chorionic gonadotropin and β human chorionic gonadotropin ratio to exclude pregnancy viability in women with a pregnancy of unknown location: A prospective multicenter cohort study. (24th November 2021)
- Main Title:
- Evaluating cut‐off levels for progesterone, β human chorionic gonadotropin and β human chorionic gonadotropin ratio to exclude pregnancy viability in women with a pregnancy of unknown location: A prospective multicenter cohort study
- Authors:
- Bobdiwala, Shabnam
Kyriacou, Christopher
Christodoulou, Evangelia
Farren, Jessica
Mitchell‐Jones, Nicola
Al‐Memar, Maya
Ayim, Francis
Chohan, Baljinder
Kirk, Emma
Abughazza, Osama
Guruwadahyarhalli, Bramara
Guha, Sharmistha
Vathanan, Veluppillai
Gould, Debbie
Stalder, Catriona
Timmerman, Dirk
Van Calster, Ben
Bourne, Tom - Abstract:
- Abstract: Introduction: There is no global agreement on how to best determine pregnancy of unknown location viability and location using biomarkers. Measurements of progesterone and β human chorionic gonadotropin (βhCG) are still used in clinical practice to exclude the possibility of a viable intrauterine pregnancy (VIUP). We evaluate the predictive value of progesterone, βhCG, and βhCG ratio cut‐off levels to exclude a VIUP in women with a pregnancy of unknown location. Material and methods: This was a secondary analysis of prospective multicenter study data of consecutive women with a pregnancy of unknown location between January 2015 and 2017 collected from dedicated early pregnancy assessment units of eight hospitals. Single progesterone and serial βhCG measurements were taken. Women were followed up until final pregnancy outcome between 11 and 14 weeks of gestation was confirmed using transvaginal ultrasonography: (1) VIUP, (2) non‐viable intrauterine pregnancy or failed pregnancy of unknown location, and (3) ectopic pregnancy or persisting pregnancy of unknown location. The predictive value of cut‐off levels for ruling out VIUP were evaluated across a range of values likely to be encountered clinically for progesterone, βhCG, and βhCG ratio. Results: Data from 2507 of 3272 (76.6%) women were suitable for analysis. All had data for βhCG levels, 2248 (89.7%) had progesterone levels, and 1809 (72.2%) had βhCG ratio. The likelihood of viability falls with the progesteroneAbstract: Introduction: There is no global agreement on how to best determine pregnancy of unknown location viability and location using biomarkers. Measurements of progesterone and β human chorionic gonadotropin (βhCG) are still used in clinical practice to exclude the possibility of a viable intrauterine pregnancy (VIUP). We evaluate the predictive value of progesterone, βhCG, and βhCG ratio cut‐off levels to exclude a VIUP in women with a pregnancy of unknown location. Material and methods: This was a secondary analysis of prospective multicenter study data of consecutive women with a pregnancy of unknown location between January 2015 and 2017 collected from dedicated early pregnancy assessment units of eight hospitals. Single progesterone and serial βhCG measurements were taken. Women were followed up until final pregnancy outcome between 11 and 14 weeks of gestation was confirmed using transvaginal ultrasonography: (1) VIUP, (2) non‐viable intrauterine pregnancy or failed pregnancy of unknown location, and (3) ectopic pregnancy or persisting pregnancy of unknown location. The predictive value of cut‐off levels for ruling out VIUP were evaluated across a range of values likely to be encountered clinically for progesterone, βhCG, and βhCG ratio. Results: Data from 2507 of 3272 (76.6%) women were suitable for analysis. All had data for βhCG levels, 2248 (89.7%) had progesterone levels, and 1809 (72.2%) had βhCG ratio. The likelihood of viability falls with the progesterone level. Although the median progesterone level associated with viability was 59 nmol/L, VIUP were identified with levels as low as 5 nmol/L. No single βhCG cut‐off reliably ruled out the presence of viability with certainty, even when the level was more than 3000 IU/L, there were 39/358 (11%) women who had a VIUP. The probability of viability decreases with the βhCG ratio. Although the median βhCG ratio associated with viability was 2.26, VIUP were identified with ratios as low as 1.02. A progesterone level below 2 nmol/L and βhCG ratio below 0.87 were unlikely to be associated with viability but were not definitive when considering multiple imputation. Conclusions: Cut‐off levels for βhCG, βhCG ratio, and progesterone are not safe to be used clinically to exclude viability in early pregnancy. Although βhCG ratio and progesterone have slightly better performance in comparison, single βhCG used in this manner is highly unreliable. … (more)
- Is Part Of:
- Acta obstetricia et gynecologica Scandinavica. Volume 101:Number 1(2022)
- Journal:
- Acta obstetricia et gynecologica Scandinavica
- Issue:
- Volume 101:Number 1(2022)
- Issue Display:
- Volume 101, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 101
- Issue:
- 1
- Issue Sort Value:
- 2022-0101-0001-0000
- Page Start:
- 46
- Page End:
- 55
- Publication Date:
- 2021-11-24
- Subjects:
- early pregnancy complications -- ectopic pregnancy -- pregnancy -- pregnancy of unknown location -- reproductive endocrinology -- ultrasound
Gynecology -- Periodicals
Pregnancy -- Periodicals
Obstetrics -- Periodicals
618.05 - Journal URLs:
- http://informahealthcare.com/loi/obs ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://www.tandf.co.uk/journals/titles/00016349.asp ↗ - DOI:
- 10.1111/aogs.14295 ↗
- Languages:
- English
- ISSNs:
- 0001-6349
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0641.600000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20173.xml