Improving efficiency in the radiation management of multiple brain metastases using a knowledge‐based planning solution for single‐isocentre volumetric modulated arc therapy (VMAT) technique. Issue 4 (26th July 2021)
- Record Type:
- Journal Article
- Title:
- Improving efficiency in the radiation management of multiple brain metastases using a knowledge‐based planning solution for single‐isocentre volumetric modulated arc therapy (VMAT) technique. Issue 4 (26th July 2021)
- Main Title:
- Improving efficiency in the radiation management of multiple brain metastases using a knowledge‐based planning solution for single‐isocentre volumetric modulated arc therapy (VMAT) technique
- Authors:
- O'Toole, James
Picton, Maddison
Perez, Mario
Back, Michael
Jayamanne, Dasantha
Le, Andrew
Wu, Kenny
Brown, Chris
Atyeo, John - Abstract:
- Abstract: Introduction: This study aimed to develop a single‐isocentre volumetric modulated arc therapy (si‐VMAT) technique for multiple brain metastases using knowledge‐based planning software, comparing it with a multiple‐isocentre stereotactic radiosurgery (mi‐SRS) planning approach. Methods: Twenty‐six si‐VMAT plans were created and uploaded into RapidPlan TM (RP) to create a si‐VMAT model. Ten patients, with 2 to 6 metastases (mets), were planned with a si‐VMAT technique utilising RP, and a mi‐SRS technique on Brainlab iPlan. Paddick Conformity Index (PCI) was used to compare conformity. The volumes of the brain receiving 15Gy, 12Gy, 10Gy, 7.5Gy and 3Gy were also compared. Retrospective treatment times from the last eight patients treated were averaged for pre‐imaging and beam on time to calculate treatment times for both techniques. Results: There was a significant difference in the PCI scores for the mi‐SRS plans ( M = 0.667, SD = 0.114) and si‐VMAT plans ( M = 0.728, SD = 0.088), with PCI values suggesting better prescription dose conformity with the si‐VMAT technique ( P = 0.014). Percentage of total brain volume receiving low‐dose wash at four of the five different dose levels was significantly less ( P < 0.05) with mi‐SRS. Average time to treat a single met with current mi‐SRS technique is 25.7 min, with each additional met requiring this same amount of time. The average time to treat 2–3 mets using si‐VMAT would be 25.3 min and 4+ metastases 33.5 min.Abstract: Introduction: This study aimed to develop a single‐isocentre volumetric modulated arc therapy (si‐VMAT) technique for multiple brain metastases using knowledge‐based planning software, comparing it with a multiple‐isocentre stereotactic radiosurgery (mi‐SRS) planning approach. Methods: Twenty‐six si‐VMAT plans were created and uploaded into RapidPlan TM (RP) to create a si‐VMAT model. Ten patients, with 2 to 6 metastases (mets), were planned with a si‐VMAT technique utilising RP, and a mi‐SRS technique on Brainlab iPlan. Paddick Conformity Index (PCI) was used to compare conformity. The volumes of the brain receiving 15Gy, 12Gy, 10Gy, 7.5Gy and 3Gy were also compared. Retrospective treatment times from the last eight patients treated were averaged for pre‐imaging and beam on time to calculate treatment times for both techniques. Results: There was a significant difference in the PCI scores for the mi‐SRS plans ( M = 0.667, SD = 0.114) and si‐VMAT plans ( M = 0.728, SD = 0.088), with PCI values suggesting better prescription dose conformity with the si‐VMAT technique ( P = 0.014). Percentage of total brain volume receiving low‐dose wash at four of the five different dose levels was significantly less ( P < 0.05) with mi‐SRS. Average time to treat a single met with current mi‐SRS technique is 25.7 min, with each additional met requiring this same amount of time. The average time to treat 2–3 mets using si‐VMAT would be 25.3 min and 4+ metastases 33.5 min. Conclusion: A knowledge‐based si‐VMAT approach was efficient in planning and treating multi metastases while achieving clinically acceptable dosimetry with respect to dose conformity and low‐dose fall off. Abstract : This study aimed to develop a single‐isocentre volumetric modulated arc therapy (si‐VMAT) technique for multiple brain metastases (MBM) using knowledge‐based planning software, comparing it with a multiple isocentre stereotactic radiosurgery (mi‐SRS) planning approach. A knowledge based si‐VMAT approach was efficient in planning and treating multi metastases while achieving clinically acceptable dosimetry with respect to dose conformity and low‐dose fall off. … (more)
- Is Part Of:
- Journal of medical radiation sciences. Volume 68:Issue 4(2021)
- Journal:
- Journal of medical radiation sciences
- Issue:
- Volume 68:Issue 4(2021)
- Issue Display:
- Volume 68, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 68
- Issue:
- 4
- Issue Sort Value:
- 2021-0068-0004-0000
- Page Start:
- 364
- Page End:
- 370
- Publication Date:
- 2021-07-26
- Subjects:
- volumetric modulated arc therapy (VMAT) -- neurological -- radiotherapy (radiation therapy) -- radiation oncology -- stereotactic radiosurgery (SRS)
Radiology, Medical -- Periodicals
Radiology, Medical -- Australia -- Periodicals
Radiology, Medical -- New Zealand -- Periodicals
Radiotherapy -- Periodicals
Diagnostic imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2051-3909 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmrs.526 ↗
- Languages:
- English
- ISSNs:
- 2051-3895
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20173.xml