Clinical significance of contact lens related changes of ocular surface tissue observed on optical coherence images. Issue 6 (December 2021)
- Record Type:
- Journal Article
- Title:
- Clinical significance of contact lens related changes of ocular surface tissue observed on optical coherence images. Issue 6 (December 2021)
- Main Title:
- Clinical significance of contact lens related changes of ocular surface tissue observed on optical coherence images
- Authors:
- Jandl, Alexandra
Ruland, Thomas
Schwarz, David
Wolffsohn, James S.
Pult, Heiko
Bandlitz, Stefan - Abstract:
- Abstract: Purpose: To investigate the relationship between the real contact lens imprint into the conjunctival tissue, observed by optical coherence tomography (OCT) and conjunctival staining and contact lens wearing comfort. Methods: 17 participants (mean age = 26.6 SD ± 3.6 years; 7 females) were fitted with three different contact lenses base curves of the same silicone hydrogel custom lens type (Visell 50; Hecht Contactlinsen, Au, Germany) in a randomised order. One lens was optimally fitted according to the manufacturer's recommendation, one fitted 0.4 mm flatter and one fitted 0.4 mm steeper. After 4 h of lens wear the contact lens edge in the area of the conjunctiva was imaged nasally and temporally using OCT (Optovue iVue SD-OCT). To correct the artefact due to optical distortion with OCT, the imprint of all worn lenses was measured on a glass plate afterwards. Conjunctival staining in the limbal region after 4 h of lens wear was classified using the CCLRU Grading Scale. Comfort scoring was based on visual analog scales from 0 (very poor) to 100 (excellent). Results: The mean conjunctival imprint of all contact lens edges was 32.0 ± 8.1 μm before and 7.3 ± 6.5 μm after distortion correction of the OCT images. The distortion corrected conjunctival imprint with the 0.4 mm steeper lens (11.5 ± 6.2 μm) was statistically significantly greater compared to the optimally fitted lens (6.5 ± 5.9 μm) (One-way ANOVA followed Tukey-test; p = 0.017) and greater compared to the 0.4Abstract: Purpose: To investigate the relationship between the real contact lens imprint into the conjunctival tissue, observed by optical coherence tomography (OCT) and conjunctival staining and contact lens wearing comfort. Methods: 17 participants (mean age = 26.6 SD ± 3.6 years; 7 females) were fitted with three different contact lenses base curves of the same silicone hydrogel custom lens type (Visell 50; Hecht Contactlinsen, Au, Germany) in a randomised order. One lens was optimally fitted according to the manufacturer's recommendation, one fitted 0.4 mm flatter and one fitted 0.4 mm steeper. After 4 h of lens wear the contact lens edge in the area of the conjunctiva was imaged nasally and temporally using OCT (Optovue iVue SD-OCT). To correct the artefact due to optical distortion with OCT, the imprint of all worn lenses was measured on a glass plate afterwards. Conjunctival staining in the limbal region after 4 h of lens wear was classified using the CCLRU Grading Scale. Comfort scoring was based on visual analog scales from 0 (very poor) to 100 (excellent). Results: The mean conjunctival imprint of all contact lens edges was 32.0 ± 8.1 μm before and 7.3 ± 6.5 μm after distortion correction of the OCT images. The distortion corrected conjunctival imprint with the 0.4 mm steeper lens (11.5 ± 6.2 μm) was statistically significantly greater compared to the optimally fitted lens (6.5 ± 5.9 μm) (One-way ANOVA followed Tukey-test; p = 0.017) and greater compared to the 0.4 mm flatter lens (3.9 ± 5.3 μm) (p < 0.001). There was no statistically significant difference between the optimally fitted lens and the 0.4 mm flatter lens (p = 0.209). The nasally measured imprint (11.4 ± 9.0 μm) was significantly greater than the temporally measured (3.3 ± 7.6 μm) (p < 0.001). There was no statistically significant correlation between the amount of conjunctival imprint and the graded conjunctival staining (p = 0.346) or the wearer's comfort (p = 0.735). Conclusions: Contact lens edges imaged by OCT exhibited displacement artefacts. The observed conjunctival imprints are a combination of real conjunctival compression and artefacts. A deeper imprint of the contact lens into the conjunctiva caused by a steeper base curve was not related to clinically significant staining or changes in comfort after 4 h of lens wear. The observed differences between nasal and temporal imprint are likely to be caused by variations of conjunctival thickness and the shape of the underlying sclera. … (more)
- Is Part Of:
- Contact lens & anterior eye. Volume 44:Issue 6(2021)
- Journal:
- Contact lens & anterior eye
- Issue:
- Volume 44:Issue 6(2021)
- Issue Display:
- Volume 44, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 44
- Issue:
- 6
- Issue Sort Value:
- 2021-0044-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-12
- Subjects:
- Contact lens edge -- Optical coherence tomography -- Displacement artefacts -- Conjunctival compression -- Conjunctival staining
Anterior segment (Eye) -- Periodicals
Contact lenses -- Periodicals
Segment antérieur (Œil) -- Périodiques
Lentilles de contact -- Périodiques
617.752305 - Journal URLs:
- http://firstsearch.oclc.org/journal=1367-0484;screen=info;ECOIP ↗
http://www.sciencedirect.com/science/journal/13670484 ↗
http://www.contactlensjournal.com/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13670484 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13670484 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clae.2020.11.008 ↗
- Languages:
- English
- ISSNs:
- 1367-0484
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3424.971000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20108.xml