Echocardiography in the time of Covid-19: Ultrasound enhancing agents save time and augment diagnostic information. (1st January 2022)
- Record Type:
- Journal Article
- Title:
- Echocardiography in the time of Covid-19: Ultrasound enhancing agents save time and augment diagnostic information. (1st January 2022)
- Main Title:
- Echocardiography in the time of Covid-19: Ultrasound enhancing agents save time and augment diagnostic information
- Authors:
- Sperling, Dylan
Lai, Ashton C.
Bienstock, Solomon W.
Samtani, Rajeev
Beerkens, Frans
Satish, Mohanchandran
Pulaski, Matthew
Edens, Madison
Oates, Connor
Kocovic, Nikola
Buckley, Samantha
Giustino, Gennaro
Lerakis, Stamatios
Liao, Steve
Stern, Eric
Croft, Lori B.
Goldman, Martin E. - Abstract:
- Abstract: Background: There are currently no clear guidelines regarding the use of ultrasound enhancing agents (UEAs) with transthoracic echocardiography (TTE) for patients hospitalized with Covid-19. We investigated whether the performance of TTE with UEAs provides more diagnostic information and allows for shorter acquisition time compared to unenhanced TTE imaging in this patient population. Methods: We analyzed the TTEs of 107 hospitalized Covid-19 patients between April and June 2020 who were administered UEAs (Definity®, Lantheus). The time to acquire images with and without UEAs was calculated. A level III echocardiographer determined if new, clinically significant findings were visualized with the addition of UEAs. Results: There was a mean of 11.84±3.59 UEA cineloops/study vs 20.74±8.10 non-UEA cineloops/study (p < 0.0001). Mean time to acquire UEA cineloop images was 72.28±28.18 s/study compared to 188.07±86.04 s/study for non-UEA cineloop images (p < 0.0001). Forty-eight patients (45%) had at least one new finding on UEA imaging, with a total of 62 new findings seen. New information gained with UEAs was more likely to be found in patients with acute respiratory distress syndrome (21 vs 9, p < 0.001) and in those on mechanical ventilation (21 vs 15, p = 0.046). Conclusions: TTE with UEAs required less time and fewer cineloop images compared to non-UEA imaging in patients hospitalized with Covid-19. Additionally, Covid-19 patients with severe respiratory diseaseAbstract: Background: There are currently no clear guidelines regarding the use of ultrasound enhancing agents (UEAs) with transthoracic echocardiography (TTE) for patients hospitalized with Covid-19. We investigated whether the performance of TTE with UEAs provides more diagnostic information and allows for shorter acquisition time compared to unenhanced TTE imaging in this patient population. Methods: We analyzed the TTEs of 107 hospitalized Covid-19 patients between April and June 2020 who were administered UEAs (Definity®, Lantheus). The time to acquire images with and without UEAs was calculated. A level III echocardiographer determined if new, clinically significant findings were visualized with the addition of UEAs. Results: There was a mean of 11.84±3.59 UEA cineloops/study vs 20.74±8.10 non-UEA cineloops/study (p < 0.0001). Mean time to acquire UEA cineloop images was 72.28±28.18 s/study compared to 188.07±86.04 s/study for non-UEA cineloop images (p < 0.0001). Forty-eight patients (45%) had at least one new finding on UEA imaging, with a total of 62 new findings seen. New information gained with UEAs was more likely to be found in patients with acute respiratory distress syndrome (21 vs 9, p < 0.001) and in those on mechanical ventilation (21 vs 15, p = 0.046). Conclusions: TTE with UEAs required less time and fewer cineloop images compared to non-UEA imaging in patients hospitalized with Covid-19. Additionally, Covid-19 patients with severe respiratory disease benefited most with regard to new diagnostic information. Health care personnel should consider early use of UEAs in select hospitalized Covid-19 patients in order to reduce exposure and optimize diagnostic yield. Highlights: Ultrasound enhancing agents improve diagnostic yield of TTE in hospitalized Covid-19 patients. Diagnostic yield is highest in patients with ARDS and those on mechanical ventilation. UEA images require significantly less time to acquire compared to unenhanced images in this patient population. … (more)
- Is Part Of:
- International journal of cardiology. Volume 346(2022)
- Journal:
- International journal of cardiology
- Issue:
- Volume 346(2022)
- Issue Display:
- Volume 346, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 346
- Issue:
- 2022
- Issue Sort Value:
- 2022-0346-2022-0000
- Page Start:
- 100
- Page End:
- 102
- Publication Date:
- 2022-01-01
- Subjects:
- Echocardiography -- Ultrasound enhancing agents -- Covid-19
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2021.11.040 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20096.xml