720 CONVENTIONAL AND SIMPLE METHODS OF MEASURING MEAN NOCTURNAL BASELINE IMPEDANCE SHOW EXCELLENT AGREEMENT. (17th September 2021)
- Record Type:
- Journal Article
- Title:
- 720 CONVENTIONAL AND SIMPLE METHODS OF MEASURING MEAN NOCTURNAL BASELINE IMPEDANCE SHOW EXCELLENT AGREEMENT. (17th September 2021)
- Main Title:
- 720 CONVENTIONAL AND SIMPLE METHODS OF MEASURING MEAN NOCTURNAL BASELINE IMPEDANCE SHOW EXCELLENT AGREEMENT
- Authors:
- Park, Jin-soo
Van der Wall, Hans
Falk, Gregory - Abstract:
- Abstract: : Mean nocturnal baseline impedance (MNBI) is a measurement that shows promise in investigating reflux disease by reflecting esophageal mucosal integrity. The conventional method of measuring MNBI is time-consuming and operator-dependent. A new, simple method of measuring MNBI has been suggested. This study aimed to report MNBI measurements by both conventional and simple methods in a cohort of laryngopharyngeal reflux (LPR) and gastro-esophageal reflux disease (GERD) patients to validate the simple measurement method. Methods: 187 patients were divided into LPR (n = 105) or GERD (n = 82) groups by predominant symptom profile, and underwent off-therapy impedance-pH monitoring. MNBI was blindly measured by both conventional and simple methods, and values were correlated. Bland–Altman plots were constructed to assess mean differences and to identify bias between the two measurement methods. Results: For the two measurement methods, mean difference in the distal esophagus was −89 (±328) ohms, in the proximal esophagus was −6 (±653) ohms, and in the pharynx was 128 (±577) ohms. There was strong correlation between conventional and simple MNBI values, with r = 0.940 in the distal esophagus, r = 0.463 in the proximal esophagus, and r = 0.712 in the pharynx (all p < 0.001). Conclusion: There was excellent agreement between conventional and simple methods of measuring MNBI, with no evidence of proportional bias. Conventional and simple MNBI values correlated excellentlyAbstract: : Mean nocturnal baseline impedance (MNBI) is a measurement that shows promise in investigating reflux disease by reflecting esophageal mucosal integrity. The conventional method of measuring MNBI is time-consuming and operator-dependent. A new, simple method of measuring MNBI has been suggested. This study aimed to report MNBI measurements by both conventional and simple methods in a cohort of laryngopharyngeal reflux (LPR) and gastro-esophageal reflux disease (GERD) patients to validate the simple measurement method. Methods: 187 patients were divided into LPR (n = 105) or GERD (n = 82) groups by predominant symptom profile, and underwent off-therapy impedance-pH monitoring. MNBI was blindly measured by both conventional and simple methods, and values were correlated. Bland–Altman plots were constructed to assess mean differences and to identify bias between the two measurement methods. Results: For the two measurement methods, mean difference in the distal esophagus was −89 (±328) ohms, in the proximal esophagus was −6 (±653) ohms, and in the pharynx was 128 (±577) ohms. There was strong correlation between conventional and simple MNBI values, with r = 0.940 in the distal esophagus, r = 0.463 in the proximal esophagus, and r = 0.712 in the pharynx (all p < 0.001). Conclusion: There was excellent agreement between conventional and simple methods of measuring MNBI, with no evidence of proportional bias. Conventional and simple MNBI values correlated excellently in the distal esophagus, and moderately well in the proximal esophagus and pharynx. This study supports the use of the simple method of measuring MNBI to enhance diagnosis of reflux disease. … (more)
- Is Part Of:
- Diseases of the esophagus. Volume 34(2021)Supplement 1
- Journal:
- Diseases of the esophagus
- Issue:
- Volume 34(2021)Supplement 1
- Issue Display:
- Volume 34, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 34
- Issue:
- 1
- Issue Sort Value:
- 2021-0034-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-09-17
- Subjects:
- Esophagus -- Diseases -- Periodicals
616.32 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1442-2050 ↗
http://www.wiley.com/bw/journal.asp?ref=1120-8694 ↗
https://academic.oup.com/dote ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1093/dote/doab052.720 ↗
- Languages:
- English
- ISSNs:
- 1120-8694
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3598.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20084.xml