Value of spectral detector computed tomography to differentiate infected from noninfected thoracoabominal fluid collections. Issue 145 (December 2021)
- Record Type:
- Journal Article
- Title:
- Value of spectral detector computed tomography to differentiate infected from noninfected thoracoabominal fluid collections. Issue 145 (December 2021)
- Main Title:
- Value of spectral detector computed tomography to differentiate infected from noninfected thoracoabominal fluid collections
- Authors:
- Reimer, Robert Peter
Gertz, Roman Johannes
Pennig, Lenhard
Henze, Jörn
Celik, Erkan
Lennartz, Simon
Maintz, David
Zopfs, David
Große Hokamp, Nils - Abstract:
- Abstract: Purpose: To investigate the diagnostic value of spectral detector CT (SDCT)-derived virtual non-contrast (VNC), virtual monoenergetic images (VMI) and iodine overlays (IO) for distinguishing infected from noninfected fluid collections (FC) in the chest or abdomen. Method: This retrospective study included 58 patients with venous phase SDCT with 77 FC. For all included FC, microbiological analysis of aspirated fluid served as reference. For quantitative analysis, wall thickness was measured, and (ROI)-based analysis performed within the fluid, the FC's wall (if any) and the aorta. Two radiologists qualitatively evaluated visibility of wall enhancement, diagnostic confidence regarding infection of fluid collection, confidence of CT-guided drainage catheter placement and visibility of anatomical landmarks in conventional images (CI) and VNC, VMI40keV, IO. Results: Wall thickness significantly differed between infected (n = 46) and noninfected (n = 31) FC (3.5 ± 1.8 mm vs. 1.4 ± 1.8 mm, AUC = 0.81; p < 0.05). Fluid attenuation and wall enhancement was significantly higher in infected as compared to noninfected FC in all reconstructions (p < 0.05, respectively). Highest AUC regarding A) attenuation in fluid was yielded in CI and VMI70, 80keV (0.75); B) wall enhancement in CI (0.88) followed by iodine concentration (0.86). Contrast-to-noise ratio of wall vs. fluid was highest in VMI40keV (p < 0.05). All assessed qualitative parameters received significantly higherAbstract: Purpose: To investigate the diagnostic value of spectral detector CT (SDCT)-derived virtual non-contrast (VNC), virtual monoenergetic images (VMI) and iodine overlays (IO) for distinguishing infected from noninfected fluid collections (FC) in the chest or abdomen. Method: This retrospective study included 58 patients with venous phase SDCT with 77 FC. For all included FC, microbiological analysis of aspirated fluid served as reference. For quantitative analysis, wall thickness was measured, and (ROI)-based analysis performed within the fluid, the FC's wall (if any) and the aorta. Two radiologists qualitatively evaluated visibility of wall enhancement, diagnostic confidence regarding infection of fluid collection, confidence of CT-guided drainage catheter placement and visibility of anatomical landmarks in conventional images (CI) and VNC, VMI40keV, IO. Results: Wall thickness significantly differed between infected (n = 46) and noninfected (n = 31) FC (3.5 ± 1.8 mm vs. 1.4 ± 1.8 mm, AUC = 0.81; p < 0.05). Fluid attenuation and wall enhancement was significantly higher in infected as compared to noninfected FC in all reconstructions (p < 0.05, respectively). Highest AUC regarding A) attenuation in fluid was yielded in CI and VMI70, 80keV (0.75); B) wall enhancement in CI (0.88) followed by iodine concentration (0.86). Contrast-to-noise ratio of wall vs. fluid was highest in VMI40keV (p < 0.05). All assessed qualitative parameters received significantly higher ratings when using spectral reconstructions vs. CI (p for all <0.05), except for visibility of wall enhancement. Conclusion: Spectral reconstructions improve the assessment of infected from noninfected thoracoabdominal fluid collections and depiction of wall enhancement. Diagnostic performance of the quantitative measurements in spectral reconstructions were comparable with measurements in conventional images. … (more)
- Is Part Of:
- European journal of radiology. Issue 145(2021)
- Journal:
- European journal of radiology
- Issue:
- Issue 145(2021)
- Issue Display:
- Volume 145, Issue 145 (2021)
- Year:
- 2021
- Volume:
- 145
- Issue:
- 145
- Issue Sort Value:
- 2021-0145-0145-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-12
- Subjects:
- AUC area under the curve -- CI conventional images -- CNR contrast-to-noise ratio -- CT computed tomography -- DECT dual-energy computed tomography -- HU Hounsfield units -- ICC intra-class correlation coefficient -- ROC receiver operating characteristics -- ROI region of interest -- SD standard deviation -- SDCT spectral detector computed tomography -- VMI virtual monoenergetic images -- VNC virtual non-contrast images
Tomography X-ray computed -- Fluid collections -- Differential diagnosis -- Infection
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2021.110037 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20101.xml