Assessing Increased Activities of the Forearm Muscles Due to Anti-Vibration Gloves: Construct Validity of a Refined Methodology. (May 2022)
- Record Type:
- Journal Article
- Title:
- Assessing Increased Activities of the Forearm Muscles Due to Anti-Vibration Gloves: Construct Validity of a Refined Methodology. (May 2022)
- Main Title:
- Assessing Increased Activities of the Forearm Muscles Due to Anti-Vibration Gloves: Construct Validity of a Refined Methodology
- Authors:
- Yao, Yumeng
Rakheja, Subhash
Larivière, Christian
Marcotte, Pierre - Abstract:
- Objective: The primary aim was to test the construct validity of a surface electromyography (EMG) measurement protocol, indirectly assessing the effects of anti-vibration (AV) gloves on activities of the forearm muscles. Background: AV gloves impose a relatively higher grip demand and thus a higher risk for musculoskeletal disorders. Consequently, activities of the forearm muscles should be considered when assessing AV glove performance. Method: Effects of AV gloves on activities of the forearm muscles (ECR: extensor carpi radialis longus; ED: extensor digitorum; FCR: flexor carpi radialis; FDS: flexor digitorum superficialis) were measured via EMG, while gripping a handle with two grip force levels. Fifteen subjects participated with 11 glove conditions, including one with bare hand. Results: Activities of ECR, FCR, mean of ECR and FCR (ECR_FCR), and mean of all four muscles were sensitive to wearing gloves. Compared with bare hand, combined ECR_FCR activities increased by 22%–78% (mean = 48%, SD = 28%) with gloves. The correlation coefficient ( r ) of ECR_FCR activities with glove thickness and manual dexterity scores were 0.74 ( p < .05) and 0.90 ( p < .001), respectively. Conclusions: A refined EMG methodology was the most sensitive to AV gloves with specific forearm muscles (ECR and FCR) and the 50-N handgrip force. Its construct validity was further substantiated by correlations with glove thickness and manual dexterity. Application: Assessment of the effect of AVObjective: The primary aim was to test the construct validity of a surface electromyography (EMG) measurement protocol, indirectly assessing the effects of anti-vibration (AV) gloves on activities of the forearm muscles. Background: AV gloves impose a relatively higher grip demand and thus a higher risk for musculoskeletal disorders. Consequently, activities of the forearm muscles should be considered when assessing AV glove performance. Method: Effects of AV gloves on activities of the forearm muscles (ECR: extensor carpi radialis longus; ED: extensor digitorum; FCR: flexor carpi radialis; FDS: flexor digitorum superficialis) were measured via EMG, while gripping a handle with two grip force levels. Fifteen subjects participated with 11 glove conditions, including one with bare hand. Results: Activities of ECR, FCR, mean of ECR and FCR (ECR_FCR), and mean of all four muscles were sensitive to wearing gloves. Compared with bare hand, combined ECR_FCR activities increased by 22%–78% (mean = 48%, SD = 28%) with gloves. The correlation coefficient ( r ) of ECR_FCR activities with glove thickness and manual dexterity scores were 0.74 ( p < .05) and 0.90 ( p < .001), respectively. Conclusions: A refined EMG methodology was the most sensitive to AV gloves with specific forearm muscles (ECR and FCR) and the 50-N handgrip force. Its construct validity was further substantiated by correlations with glove thickness and manual dexterity. Application: Assessment of the effect of AV gloves on activities of the forearm muscles can yield design guidance for AV gloves to reduce grip exertion by the gloved hand. … (more)
- Is Part Of:
- Human factors. Volume 64:Number 3(2022)
- Journal:
- Human factors
- Issue:
- Volume 64:Number 3(2022)
- Issue Display:
- Volume 64, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 64
- Issue:
- 3
- Issue Sort Value:
- 2022-0064-0003-0000
- Page Start:
- 466
- Page End:
- 481
- Publication Date:
- 2022-05
- Subjects:
- anti-vibration gloves -- activities of forearm muscles -- electromyography -- grip strength
Human engineering -- Periodicals
620.82 - Journal URLs:
- http://hfs.sagepub.com/ ↗
http://www.sagepublications.com/ ↗ - DOI:
- 10.1177/0018720820948303 ↗
- Languages:
- English
- ISSNs:
- 0018-7208
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20091.xml