Modified Look-Locker Inverse-Recovery (MOLLI) Sequence of Quantitative Imaging in Dirty Magnetic Resonance Longitudinal Relaxation Time Diagnostic Value of GE Combined with Longitudinal Relaxation Time Quantitative Imaging for Myocardial Amyloidosis. (19th October 2021)
- Record Type:
- Journal Article
- Title:
- Modified Look-Locker Inverse-Recovery (MOLLI) Sequence of Quantitative Imaging in Dirty Magnetic Resonance Longitudinal Relaxation Time Diagnostic Value of GE Combined with Longitudinal Relaxation Time Quantitative Imaging for Myocardial Amyloidosis. (19th October 2021)
- Main Title:
- Modified Look-Locker Inverse-Recovery (MOLLI) Sequence of Quantitative Imaging in Dirty Magnetic Resonance Longitudinal Relaxation Time Diagnostic Value of GE Combined with Longitudinal Relaxation Time Quantitative Imaging for Myocardial Amyloidosis
- Authors:
- Lao, Qun
Xia, Wenping
Jin, Jing
Jia, Yuzhu
Feng, Jianju - Other Names:
- Xia Kaijian Academic Editor.
- Abstract:
- Abstract : The pathological changes of myocarditis include degeneration and necrosis of myocardial cells and infiltration of inflammatory cells in the myocardial interstitium, accompanied by obvious myocardial fibrosis. Myocardial fibrosis is a determinant of ventricular remodeling and an important indicator of the classification of clinical risk factors and has an important value in evaluating the prognosis of heart disease. Cardiac magnetic resonance (CMR) is the "gold standard" for evaluating the shape and function of the heart, and it can show the characteristic pathological changes of myocardial tissue. The traditional gadolinium imaging agent delays the enhanced sequence images to visually show the extent of the affected myocardial fibrosis, but it cannot effectively identify small focal fibrosis or widespread diffuse fibrosis. The CMR longitudinal relaxation time quantitative technique can directly measure the relaxation time (T1) determined by the myocardial tissue and does not depend on the signal strength of the reference tissue and can quantitatively analyze the affected myocardium. In this study, the initial and enhanced quantitative imaging techniques of CMR were used to measure the magnetic value of the myocardium in patients with myocarditis, to explore the diagnostic value of myocardial fibrosis, and to analyze the correlation between cardiac fibrosis and cardiac function.
- Is Part Of:
- Journal of healthcare engineering. Volume 2021(2021)
- Journal:
- Journal of healthcare engineering
- Issue:
- Volume 2021(2021)
- Issue Display:
- Volume 2021, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 2021
- Issue:
- 2021
- Issue Sort Value:
- 2021-2021-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-19
- Subjects:
- Hospital buildings -- Environmental engineering -- Periodicals
Medical technology -- Periodicals
Medical informatics -- Periodicals
610.28 - Journal URLs:
- http://www.hindawi.com/journals/jhe/ ↗
http://multi-science.metapress.com/content/r03085752427/?p=bacc87ee7c194c1aa6a045ab293b1f0f&pi=2 ↗ - DOI:
- 10.1155/2021/2800891 ↗
- Languages:
- English
- ISSNs:
- 2040-2295
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 20089.xml