Myocardial deformation assessed by CMR in children after multisystem inflammatory syndrome (MIS-C). (1st January 2022)
- Record Type:
- Journal Article
- Title:
- Myocardial deformation assessed by CMR in children after multisystem inflammatory syndrome (MIS-C). (1st January 2022)
- Main Title:
- Myocardial deformation assessed by CMR in children after multisystem inflammatory syndrome (MIS-C)
- Authors:
- Krupickova, Sylvia
Bautista-Rodriguez, Carles
Hatipoglu, Suzan
Kang, Heechan
Fraisse, Alain
Di Salvo, Giovanni
Piccinelli, Enrico
Rowlinson, Giselle
Lane, Mary
Altamar Bermejo, Ivan
Moscatelli, Sara
Wage, Rick
Mohiaddin, Raad
Pennell, Dudley J.
Voges, Inga - Abstract:
- Abstract: Background: Short-term sequelae of Multisystem Inflammatory Syndrome in Children (MIS-C), recently published by our institution, showed rapid improvement of the cardiac abnormalities within a few weeks after the onset of the disease. However, subtle residual abnormalities, affecting mainly the myocardial interstitium, were shown in some of the patients. The current study aimed to assess myocardial deformation with CMR shortly after MIS-C. Methods: Sixty children were included into the study; 30 following MIS-C (onset-to-scan mean 27 days, SD 11) and 30 controls. Strain values were compared between patients and controls and additionally to published paediatric normal CMR values. U-Mann Whitney test was used for comparison of the myocardial deformation between patients and controls. Results: Median age of the patients was 9.0 years (range 0.99–14.4) and controls 9.8 years (range 4.7–14.9). All conventional CMR parameters in patients were in normal range. Strain values were significantly lower in patients than in controls. When compared to published centile graphs, radial and circumferential global strain was within 2.5th and 97.5th centile in all patients. Eleven patients had global longitudinal strain between 2.5th centile and 50th centile, 1 patient was below 2.5th centile and all the others above 50th centile. Only 3 controls had global longitudinal strain between 2.5th centile and 50th centile, all other had higher strain. Conclusions: This study demonstratesAbstract: Background: Short-term sequelae of Multisystem Inflammatory Syndrome in Children (MIS-C), recently published by our institution, showed rapid improvement of the cardiac abnormalities within a few weeks after the onset of the disease. However, subtle residual abnormalities, affecting mainly the myocardial interstitium, were shown in some of the patients. The current study aimed to assess myocardial deformation with CMR shortly after MIS-C. Methods: Sixty children were included into the study; 30 following MIS-C (onset-to-scan mean 27 days, SD 11) and 30 controls. Strain values were compared between patients and controls and additionally to published paediatric normal CMR values. U-Mann Whitney test was used for comparison of the myocardial deformation between patients and controls. Results: Median age of the patients was 9.0 years (range 0.99–14.4) and controls 9.8 years (range 4.7–14.9). All conventional CMR parameters in patients were in normal range. Strain values were significantly lower in patients than in controls. When compared to published centile graphs, radial and circumferential global strain was within 2.5th and 97.5th centile in all patients. Eleven patients had global longitudinal strain between 2.5th centile and 50th centile, 1 patient was below 2.5th centile and all the others above 50th centile. Only 3 controls had global longitudinal strain between 2.5th centile and 50th centile, all other had higher strain. Conclusions: This study demonstrates that myocardial deformation indices measured by CMR are within normal range in the vast majority of the patients within a few weeks after the onset of MIS-C. However, when compared to healthy controls, all strain parameters were lower in patients. Highlights: Myocardial deformation indices are within normal range in the vast majority of the patients after MIS-C. All strain parameters are lower in patients than in healthy controls. All conventional CMR parameters in patients are in normal range. … (more)
- Is Part Of:
- International journal of cardiology. Volume 346(2022)
- Journal:
- International journal of cardiology
- Issue:
- Volume 346(2022)
- Issue Display:
- Volume 346, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 346
- Issue:
- 2022
- Issue Sort Value:
- 2022-0346-2022-0000
- Page Start:
- 105
- Page End:
- 106
- Publication Date:
- 2022-01-01
- Subjects:
- MIS-C -- Children -- CMR -- Myocardial deformation
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2021.11.036 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20067.xml