Long-term experiment on p-type crystalline PV module with potential induced degradation: Impact on power performance and evaluation of recovery mode. (January 2022)
- Record Type:
- Journal Article
- Title:
- Long-term experiment on p-type crystalline PV module with potential induced degradation: Impact on power performance and evaluation of recovery mode. (January 2022)
- Main Title:
- Long-term experiment on p-type crystalline PV module with potential induced degradation: Impact on power performance and evaluation of recovery mode
- Authors:
- Bouaichi, Abdellatif
Merrouni, Ahmed Alami
El Amrani, Aumeur
Jaeckel, Bengt
Hajjaj, Charaf
Naimi, Zakaria
Messaoudi, Choukri - Abstract:
- Abstract: The potential induced degradation (PID) phenomenon of p-type c-Si photovoltaic technology is a severe degradation mode that caught the attention of researchers since it can significantly affect the energy production of the PV plants. Various modeling/lab-tests have been conducted but very few are the in-situ experiments estimating the behavior of PID under real operating conditions on desert climate. In this context, the present work inspects the PID presence in an operational PV plant of a p-type monocrystalline silicon (mono-Si) technology with a capacity of 22, 2-kW, installed in a Bsh (Hot semi-arid) climate. Besides, the assessment of the PID's impact on the affected modules have been measured and evaluated using several inspection techniques; electroluminescence (EL), thermography (IR) and I–V curve. Furthermore, we have evaluated the PID recovery process in the affected PV modules, and its first appearance in non-affected modules using a polarity inversion technique. The key finding shows that PID can be considered a significant degradation mode affecting the durability and the power output of crystalline silicon modules. Furthermore, the bias polarity change (to only demonstrate that the PID can be regenerated) can recover the PID causing power losses after a very short period. The results of this study demonstrate that PID can rapidly occur within three months in a semi-arid climate of Morocco. Highlights: In-situ experiments estimating the behavior of PIDAbstract: The potential induced degradation (PID) phenomenon of p-type c-Si photovoltaic technology is a severe degradation mode that caught the attention of researchers since it can significantly affect the energy production of the PV plants. Various modeling/lab-tests have been conducted but very few are the in-situ experiments estimating the behavior of PID under real operating conditions on desert climate. In this context, the present work inspects the PID presence in an operational PV plant of a p-type monocrystalline silicon (mono-Si) technology with a capacity of 22, 2-kW, installed in a Bsh (Hot semi-arid) climate. Besides, the assessment of the PID's impact on the affected modules have been measured and evaluated using several inspection techniques; electroluminescence (EL), thermography (IR) and I–V curve. Furthermore, we have evaluated the PID recovery process in the affected PV modules, and its first appearance in non-affected modules using a polarity inversion technique. The key finding shows that PID can be considered a significant degradation mode affecting the durability and the power output of crystalline silicon modules. Furthermore, the bias polarity change (to only demonstrate that the PID can be regenerated) can recover the PID causing power losses after a very short period. The results of this study demonstrate that PID can rapidly occur within three months in a semi-arid climate of Morocco. Highlights: In-situ experiments estimating the behavior of PID under real operating conditions on desert climate. The effect of configuration change (polarity) on the PV modules properties –electrical parameter and aging mechanism. The polarity inversion technique can recover the PID causing power losses after a very short period. … (more)
- Is Part Of:
- Renewable energy. Volume 183(2022)
- Journal:
- Renewable energy
- Issue:
- Volume 183(2022)
- Issue Display:
- Volume 183, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 183
- Issue:
- 2022
- Issue Sort Value:
- 2022-0183-2022-0000
- Page Start:
- 472
- Page End:
- 479
- Publication Date:
- 2022-01
- Subjects:
- PID -- Outdoor inspection -- Power drop -- Recovery period -- Electroluminescence -- Bias polarity
Renewable energy sources -- Periodicals
Power resources -- Periodicals
Énergies renouvelables -- Périodiques
Ressources énergétiques -- Périodiques
333.794 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09601481 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/renewable-energy/ ↗ - DOI:
- 10.1016/j.renene.2021.11.031 ↗
- Languages:
- English
- ISSNs:
- 0960-1481
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7364.187000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20055.xml