Diagnostic accuracy of optical coherence tomography for surgical margin assessment of feline injection‐site sarcoma. (14th September 2021)
- Record Type:
- Journal Article
- Title:
- Diagnostic accuracy of optical coherence tomography for surgical margin assessment of feline injection‐site sarcoma. (14th September 2021)
- Main Title:
- Diagnostic accuracy of optical coherence tomography for surgical margin assessment of feline injection‐site sarcoma
- Authors:
- Coleman, Mary J.
Selmic, Laura E.
Samuelson, Jonathan P.
Jennings, Ryan
Huang, Pin‐Chieh
McLaughlin, Eric M.
Wavreille, Vincent A.
Dornbusch, Josephine A.
Lapsley, Janis
Howard, James
Cheng, Edward
Kalamaras, Alex
Hearon, Kendra
Cray, Megan
Grimes, Janet
Wustefeld‐Janssens, Brandan
Kennedy, Katie
Skinner, Owen
Amsellem, Pierre
Boppart, Stephen A. - Other Names:
- Selmic Laura guestEditor.
Culp William guestEditor. - Abstract:
- Abstract: The invasive, locally aggressive nature of feline injection‐site sarcomas (FISSs) poses a unique challenge for surgeons to obtain complete margins with surgical excision. Optical coherence tomography (OCT), an imaging technology that uses light waves to generate real‐time views of tissue architecture, provides an emerging solution to this dilemma by allowing fast, high‐resolution scanning of surgical margins. The purpose of this study was to use OCT to assess surgical margins of FISS and to evaluate the diagnostic accuracy of OCT for detecting residual cancer using six evaluators of varying experience. Five FISSs were imaged with OCT to create a training set of OCT images that were compared with histopathology. Next, 25 FISSs were imaged with OCT prior to histopathology. Six evaluators of varying experience participated in a training session on OCT imaging after which each of the evaluators was given a dataset that included OCT images and videos to score on a scale from cancerous to non‐cancerous. Diagnostic accuracy statistics were calculated. The overall sensitivity and specificity for classification of OCT images by evaluators were 78.9% and 77.6%, respectively. Correct classification rate of OCT images was associated with experience, while individual sensitivities and specificities had more variation between experience groups. This study demonstrates the ability of evaluators to correctly classify OCT images with overall low levels of experience and trainingAbstract: The invasive, locally aggressive nature of feline injection‐site sarcomas (FISSs) poses a unique challenge for surgeons to obtain complete margins with surgical excision. Optical coherence tomography (OCT), an imaging technology that uses light waves to generate real‐time views of tissue architecture, provides an emerging solution to this dilemma by allowing fast, high‐resolution scanning of surgical margins. The purpose of this study was to use OCT to assess surgical margins of FISS and to evaluate the diagnostic accuracy of OCT for detecting residual cancer using six evaluators of varying experience. Five FISSs were imaged with OCT to create a training set of OCT images that were compared with histopathology. Next, 25 FISSs were imaged with OCT prior to histopathology. Six evaluators of varying experience participated in a training session on OCT imaging after which each of the evaluators was given a dataset that included OCT images and videos to score on a scale from cancerous to non‐cancerous. Diagnostic accuracy statistics were calculated. The overall sensitivity and specificity for classification of OCT images by evaluators were 78.9% and 77.6%, respectively. Correct classification rate of OCT images was associated with experience, while individual sensitivities and specificities had more variation between experience groups. This study demonstrates the ability of evaluators to correctly classify OCT images with overall low levels of experience and training and also illustrates areas where increased training can improve accuracy of evaluators in interpretation of OCT surgical margin images. … (more)
- Is Part Of:
- Veterinary and comparative oncology. Volume 19:Number 4(2021)
- Journal:
- Veterinary and comparative oncology
- Issue:
- Volume 19:Number 4(2021)
- Issue Display:
- Volume 19, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 19
- Issue:
- 4
- Issue Sort Value:
- 2021-0019-0004-0000
- Page Start:
- 632
- Page End:
- 640
- Publication Date:
- 2021-09-14
- Subjects:
- cats -- margins of excision -- optical coherence -- sarcomas -- soft‐tissue neoplasms -- tomography
Veterinary oncology -- Periodicals
Neoplasms -- veterinary -- Periodicals
636.0896994005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1476-5810;screen=info;ECOIP ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1476-5829 ↗
http://www.blackwell-synergy.com/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/vco.12766 ↗
- Languages:
- English
- ISSNs:
- 1476-5810
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9226.528800
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20021.xml