AB1110 QUANTUM BLUE® RAPID TDM ASSAY STANDARDIZATION HIGHLY CORRELATES WITH WHO INTERNATIONAL STANDARD FOR INFLIXIMAB. (2nd June 2020)
- Record Type:
- Journal Article
- Title:
- AB1110 QUANTUM BLUE® RAPID TDM ASSAY STANDARDIZATION HIGHLY CORRELATES WITH WHO INTERNATIONAL STANDARD FOR INFLIXIMAB. (2nd June 2020)
- Main Title:
- AB1110 QUANTUM BLUE® RAPID TDM ASSAY STANDARDIZATION HIGHLY CORRELATES WITH WHO INTERNATIONAL STANDARD FOR INFLIXIMAB
- Authors:
- Keller, E.
Spies, P.
Frei, F.
Eckhardt, V.
Schuster, T.
Schneider, M. - Abstract:
- Abstract : Background: Therapeutic drug monitoring of RA patients under anti-TNF therapy is based on trough level determination of the drug. Rapid assays and multiple ELISAs are available that measure anti-TNF biologics. An international standard is required to improve comparability among different assays. Recently, WHO introduced a series of anti-TNF standards for etanercept, adalimumab and infliximab. This is the first step for achieving common standardisation of assays available on the market. Objectives: The aim of the study was to evaluate the correlation of the WHO standard with BÜHLMANN Quantum Blue® Infliximab standardization and to compare spiking recovery in three commercially available infliximab ELISAs and one infliximab rapid test. Methods: Calibration curves were generated with BÜHLMANN calibrators and with calibrators made from WHO international standard for infliximab (NIBSC 16/170). Twenty-six serum samples, covering a concentration range from 0.5 µg/mL to 19 µg/mL, were analyzed with both calibration curves and compared by Bland-Altman and Passing-Bablok analysis. Furthermore, recovery of six serum samples spiked with WHO international standard for infliximab was determined in Theradiag LISA TRACKER Infliximab (a), Grifols/Progenika Promonitor-IFX (b), Immundiagnostik IDKmonitor Infliximab drug level (c) and BÜHLMANN Quantum Blue® Infliximab (d). Spiking recovery experiments were performed according to Westgard 2008. Results: The sample values gained withAbstract : Background: Therapeutic drug monitoring of RA patients under anti-TNF therapy is based on trough level determination of the drug. Rapid assays and multiple ELISAs are available that measure anti-TNF biologics. An international standard is required to improve comparability among different assays. Recently, WHO introduced a series of anti-TNF standards for etanercept, adalimumab and infliximab. This is the first step for achieving common standardisation of assays available on the market. Objectives: The aim of the study was to evaluate the correlation of the WHO standard with BÜHLMANN Quantum Blue® Infliximab standardization and to compare spiking recovery in three commercially available infliximab ELISAs and one infliximab rapid test. Methods: Calibration curves were generated with BÜHLMANN calibrators and with calibrators made from WHO international standard for infliximab (NIBSC 16/170). Twenty-six serum samples, covering a concentration range from 0.5 µg/mL to 19 µg/mL, were analyzed with both calibration curves and compared by Bland-Altman and Passing-Bablok analysis. Furthermore, recovery of six serum samples spiked with WHO international standard for infliximab was determined in Theradiag LISA TRACKER Infliximab (a), Grifols/Progenika Promonitor-IFX (b), Immundiagnostik IDKmonitor Infliximab drug level (c) and BÜHLMANN Quantum Blue® Infliximab (d). Spiking recovery experiments were performed according to Westgard 2008. Results: The sample values gained with BÜHLMANN calibrators showed an excellent correlation with values gained with the WHO international standard for infliximab as calibrator. Passing-Bablok regression analysis revealed a slope of 0.96 and correlation coefficient (R) of 0.99. Bland-Altman analysis revealed a mean difference in the obtained values of less than five percent. Regarding spiking recovery analysis, all tests exhibit an excellent mean recovery of 101% (85-114%; a), 99% (91-105%; b); 101% (95-107%; c) and 94% (88-100%, d). Conclusion: Current standardization of Quantum Blue® Infliximab rapid test correlates very well with the WHO international standard for infliximab (NIBSC 16/170). Spiking recovery was highly comparable for ELISAs and the Quantum Blue® Infliximab assay. This rapid test represents a unique and modern analytical method, for fast time-to-result and simplicity of usage in a more patient near medical environment. References: [1]Westgard, James. (2008). Basic Method Validation. Disclosure of Interests: None declared … (more)
- Is Part Of:
- Annals of the rheumatic diseases. Volume 79(2020)Supplement 1
- Journal:
- Annals of the rheumatic diseases
- Issue:
- Volume 79(2020)Supplement 1
- Issue Display:
- Volume 79, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 79
- Issue:
- 1
- Issue Sort Value:
- 2020-0079-0001-0000
- Page Start:
- 1844
- Page End:
- 1845
- Publication Date:
- 2020-06-02
- Subjects:
- Rheumatism -- Periodicals
616.723005 - Journal URLs:
- http://ard.bmjjournals.com/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=149&action=archive ↗
http://www.bmj.com/archive ↗
http://gateway.ovid.com/server3/ovidweb.cgi?T=JS&MODE=ovid&D=ovft&PAGE=titles&SEARCH=annals+of+the+rheumatic+diseases.tj&NEWS=N ↗ - DOI:
- 10.1136/annrheumdis-2020-eular.3322 ↗
- Languages:
- English
- ISSNs:
- 0003-4967
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20020.xml