Comparison of Existing and New Total Knee Arthroplasty Implant Systems From the Same Manufacturer: A Prospective, Multicenter Study. (15th December 2021)
- Record Type:
- Journal Article
- Title:
- Comparison of Existing and New Total Knee Arthroplasty Implant Systems From the Same Manufacturer: A Prospective, Multicenter Study. (15th December 2021)
- Main Title:
- Comparison of Existing and New Total Knee Arthroplasty Implant Systems From the Same Manufacturer: A Prospective, Multicenter Study
- Authors:
- Hamilton, William G.
Brenkel, Ivan J.
Barnett, Steven L.
Allen, Paul W.
Dwyer, Kimberly A.
Lesko, James P.
Kantor, Stephen R.
Clatworthy, Mark G. - Abstract:
- Abstract : Introduction: This study evaluated total knee arthroplasty (TKA) outcomes for an Existing-TKA versus New-TKA from the same manufacturer. Methods: TKA outcomes for 752 with Existing-TKA versus 1129 subjects with New-TKA were followed through 2 years using patient-reported outcome measures (PROMs). Responders were assessed per Outcome Measures in Rheumatology-Osteoarthritis Research Society International criteria. Kaplan-Meier implant survivorship was estimated. Radiographs had an independent radiographic review. Results: Two-year follow-up was 84.6% (636/752) for Existing-TKA and 82.5% (931/1129) for New-TKA. Two-year PROMs mean outcomes for New-TKA versus Existing-TKA at 2 years were: Knee Injury and Osteoarthritis Outcome Score (ADL: 89.0 versus 86.8, P = 0.005; pain: 88.9 versus 87.1, P = 0.019; symptoms: 84.1 versus 82.2, P = 0.017; Sport/Rec: 63.9 versus 58.8, P = 0.001; and QOL: 77.0 versus 73.5, P = 0.003), Patient's Knee Implant Performance (overall: 76.5 versus 73.5, P = 0.003; confidence: 8.4 versus 8.1, P = 0.004; stability: 8.6 versus 8.3, P = 0.006; satisfaction: 8.3 versus 8.1, P = 0.042; and modifying activities: 6.6 versus 6.4, P = 0.334), Oxford Knee Score (41.9 versus 41.1, P = 0.027), and EQ5D-3L (0.88 versus 0.88, P = 0.737). Two-year responder rates using WOMAC were 93.9% versus 90.6% ( P = 0.018) for New-TKA versus Existing-TKA. Independent radiographic review showed that tibial and femoral radiolucencies ≥2 mm were similar ( P ≥ 0.05) orAbstract : Introduction: This study evaluated total knee arthroplasty (TKA) outcomes for an Existing-TKA versus New-TKA from the same manufacturer. Methods: TKA outcomes for 752 with Existing-TKA versus 1129 subjects with New-TKA were followed through 2 years using patient-reported outcome measures (PROMs). Responders were assessed per Outcome Measures in Rheumatology-Osteoarthritis Research Society International criteria. Kaplan-Meier implant survivorship was estimated. Radiographs had an independent radiographic review. Results: Two-year follow-up was 84.6% (636/752) for Existing-TKA and 82.5% (931/1129) for New-TKA. Two-year PROMs mean outcomes for New-TKA versus Existing-TKA at 2 years were: Knee Injury and Osteoarthritis Outcome Score (ADL: 89.0 versus 86.8, P = 0.005; pain: 88.9 versus 87.1, P = 0.019; symptoms: 84.1 versus 82.2, P = 0.017; Sport/Rec: 63.9 versus 58.8, P = 0.001; and QOL: 77.0 versus 73.5, P = 0.003), Patient's Knee Implant Performance (overall: 76.5 versus 73.5, P = 0.003; confidence: 8.4 versus 8.1, P = 0.004; stability: 8.6 versus 8.3, P = 0.006; satisfaction: 8.3 versus 8.1, P = 0.042; and modifying activities: 6.6 versus 6.4, P = 0.334), Oxford Knee Score (41.9 versus 41.1, P = 0.027), and EQ5D-3L (0.88 versus 0.88, P = 0.737). Two-year responder rates using WOMAC were 93.9% versus 90.6% ( P = 0.018) for New-TKA versus Existing-TKA. Independent radiographic review showed that tibial and femoral radiolucencies ≥2 mm were similar ( P ≥ 0.05) or favored New-TKA. Implant survivorship was similar between groups (log-rank P = 0.9994). Discussion: New-TKA versus Existing-TKA demonstrated slightly better PROMs with similar radiographic and implant survivorship outcomes. … (more)
- Is Part Of:
- Journal of the AAOS. Volume 5:Number 12(2021)
- Journal:
- Journal of the AAOS
- Issue:
- Volume 5:Number 12(2021)
- Issue Display:
- Volume 5, Issue 12 (2021)
- Year:
- 2021
- Volume:
- 5
- Issue:
- 12
- Issue Sort Value:
- 2021-0005-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-12-15
- Subjects:
- Orthopedic surgery -- Periodicals
617.4705 - Journal URLs:
- http://journals.lww.com/jaaosglobal/Pages/default.aspx ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.5435/JAAOSGlobal-D-21-00136 ↗
- Languages:
- English
- ISSNs:
- 2474-7661
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20007.xml