The effect of cement augmentation on pedicle screw fixation under various load cases: results from a combined experimental, micro-CT, and micro-finite element analysis. Issue 12 (8th December 2021)
- Record Type:
- Journal Article
- Title:
- The effect of cement augmentation on pedicle screw fixation under various load cases: results from a combined experimental, micro-CT, and micro-finite element analysis. Issue 12 (8th December 2021)
- Main Title:
- The effect of cement augmentation on pedicle screw fixation under various load cases
- Authors:
- Chevalier, Yan
Matsuura, Maiko
Krüger, Sven
Traxler, Hannes
Fleege†, Christoph
Rauschmann, Michael
Schilling, Christoph - Abstract:
- Abstract : Aims: Anchorage of pedicle screw rod instrumentation in the elderly spine with poor bone quality remains challenging. Our study aims to evaluate how the screw bone anchorage is affected by screw design, bone quality, loading conditions, and cementing techniques. Methods: Micro-finite element (µFE) models were created from micro-CT (μCT) scans of vertebrae implanted with two types of pedicle screws (L: Ennovate and R: S 4 ). Simulations were conducted for a 10 mm radius region of interest (ROI) around each screw and for a full vertebra (FV) where different cementing scenarios were simulated around the screw tips. Stiffness was calculated in pull-out and anterior bending loads. Results: Experimental pull-out strengths were excellently correlated to the µFE pull-out stiffness of the ROI (R 2 > 0.87) and FV (R 2 > 0.84) models. No significant difference due to screw design was observed. Cement augmentation increased pull-out stiffness by up to 94% and 48% for L and R screws, respectively, but only increased bending stiffness by up to 6.9% and 1.5%, respectively. Cementing involving only one screw tip resulted in lower stiffness increases in all tested screw designs and loading cases. The stiffening effect of cement augmentation on pull-out and bending stiffness was strongly and negatively correlated to local bone density around the screw (correlation coefficient ( R ) = -0.95). Conclusion: This combined experimental, µCT and µFE study showed that regional analyses mayAbstract : Aims: Anchorage of pedicle screw rod instrumentation in the elderly spine with poor bone quality remains challenging. Our study aims to evaluate how the screw bone anchorage is affected by screw design, bone quality, loading conditions, and cementing techniques. Methods: Micro-finite element (µFE) models were created from micro-CT (μCT) scans of vertebrae implanted with two types of pedicle screws (L: Ennovate and R: S 4 ). Simulations were conducted for a 10 mm radius region of interest (ROI) around each screw and for a full vertebra (FV) where different cementing scenarios were simulated around the screw tips. Stiffness was calculated in pull-out and anterior bending loads. Results: Experimental pull-out strengths were excellently correlated to the µFE pull-out stiffness of the ROI (R 2 > 0.87) and FV (R 2 > 0.84) models. No significant difference due to screw design was observed. Cement augmentation increased pull-out stiffness by up to 94% and 48% for L and R screws, respectively, but only increased bending stiffness by up to 6.9% and 1.5%, respectively. Cementing involving only one screw tip resulted in lower stiffness increases in all tested screw designs and loading cases. The stiffening effect of cement augmentation on pull-out and bending stiffness was strongly and negatively correlated to local bone density around the screw (correlation coefficient ( R ) = -0.95). Conclusion: This combined experimental, µCT and µFE study showed that regional analyses may be sufficient to predict fixation strength in pull-out and that full analyses could show that cement augmentation around pedicle screws increased fixation stiffness in both pull-out and bending, especially for low-density bone. Cite this article: Bone Joint Res 2021;10(12):797–806. … (more)
- Is Part Of:
- Bone & joint research. Volume 10:Issue 12(2021)
- Journal:
- Bone & joint research
- Issue:
- Volume 10:Issue 12(2021)
- Issue Display:
- Volume 10, Issue 12 (2021)
- Year:
- 2021
- Volume:
- 10
- Issue:
- 12
- Issue Sort Value:
- 2021-0010-0012-0000
- Page Start:
- 797
- Page End:
- 806
- Publication Date:
- 2021-12-08
- Subjects:
- Pedicle screw -- Micro-CT -- Micro-finite element analysis -- Cement augmentation -- Pedicle screw fixation -- pedicle screws -- Stiffness -- bone quality -- Vertebrae -- strengths -- bone density -- vertebral bone -- region of interest
Musculoskeletal system -- Periodicals
573.705 - Journal URLs:
- http://www.bjr.boneandjoint.org.uk/ ↗
- DOI:
- 10.1302/2046-3758.1012.BJR-2020-0533.R1 ↗
- Languages:
- English
- ISSNs:
- 2046-3758
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library STI - ELD Digital store
- Ingest File:
- 20015.xml