Relaxation‐corrected macromolecular model enables determination of 1H longitudinal T1‐relaxation times and concentrations of human brain metabolites at 9.4T. Issue 1 (10th August 2021)
- Record Type:
- Journal Article
- Title:
- Relaxation‐corrected macromolecular model enables determination of 1H longitudinal T1‐relaxation times and concentrations of human brain metabolites at 9.4T. Issue 1 (10th August 2021)
- Main Title:
- Relaxation‐corrected macromolecular model enables determination of 1H longitudinal T1‐relaxation times and concentrations of human brain metabolites at 9.4T
- Authors:
- Wright, Andrew Martin
Murali‐Manohar, Saipavitra
Borbath, Tamas
Avdievich, Nikolai I.
Henning, Anke - Abstract:
- Abstract : Purpose: Ultrahigh field MRS has improved characterization of the neurochemical profile. To compare results obtained at 9.4T to those from lower field strengths, it is of interest to quantify the concentrations of metabolites measured. Thus, measuring T1 ‐relaxation times is necessary to correct for T1 ‐weighting that occurs in acquisitions for single‐voxel spectroscopy and spectroscopic imaging. A macromolecule (MM) simulation model was developed to fit MM contributions to the short TE inversion series used to measure T1 ‐relaxation times. Methods: An inversion series with seven time points was acquired with metabolite‐cycled STEAM to estimate T1 ‐relaxation times of metabolites. A short TE was employed in this study to retain signals from metabolites with short T2 ‐relaxation times and J‐couplings. The underlying macromolecule spectrum was corrected by developing a sequence‐specific, relaxation‐corrected simulated MM model. Quantification of metabolite peaks was performed using internal water referencing and relaxation corrections. Results: T1 ‐relaxation times for metabolites range from approximately 750 to approximately 2000 ms and approximately 1000 to approximately 2400 ms in gray matter (GM)‐ and white matter (WM)‐ rich voxels, respectively. Quantification of metabolites was compared between GM and WM voxels, as well as between results that used a simulated MM spectrum against those that used an experimentally acquired MM spectrum. Metabolite concentrationsAbstract : Purpose: Ultrahigh field MRS has improved characterization of the neurochemical profile. To compare results obtained at 9.4T to those from lower field strengths, it is of interest to quantify the concentrations of metabolites measured. Thus, measuring T1 ‐relaxation times is necessary to correct for T1 ‐weighting that occurs in acquisitions for single‐voxel spectroscopy and spectroscopic imaging. A macromolecule (MM) simulation model was developed to fit MM contributions to the short TE inversion series used to measure T1 ‐relaxation times. Methods: An inversion series with seven time points was acquired with metabolite‐cycled STEAM to estimate T1 ‐relaxation times of metabolites. A short TE was employed in this study to retain signals from metabolites with short T2 ‐relaxation times and J‐couplings. The underlying macromolecule spectrum was corrected by developing a sequence‐specific, relaxation‐corrected simulated MM model. Quantification of metabolite peaks was performed using internal water referencing and relaxation corrections. Results: T1 ‐relaxation times for metabolites range from approximately 750 to approximately 2000 ms and approximately 1000 to approximately 2400 ms in gray matter (GM)‐ and white matter (WM)‐ rich voxels, respectively. Quantification of metabolites was compared between GM and WM voxels, as well as between results that used a simulated MM spectrum against those that used an experimentally acquired MM spectrum. Metabolite concentrations are reported in mmol/kg quantities. Conclusion: T1 ‐relaxation times are reported for nonsinglet resonances for the first time at 9.4T by use of a MM simulation model to account for contributions from the MM spectrum. In addition to T1 ‐relaxation times, quantification results of metabolites from GM‐ and WM‐rich voxels are reported. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 87:Issue 1(2022)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 87:Issue 1(2022)
- Issue Display:
- Volume 87, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 87
- Issue:
- 1
- Issue Sort Value:
- 2022-0087-0001-0000
- Page Start:
- 33
- Page End:
- 49
- Publication Date:
- 2021-08-10
- Subjects:
- macromolecules -- magnetic resonance spectroscopy (MRS) -- quantification -- T1 relaxation times -- ultrahigh field
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28958 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20008.xml