Review of extremity dosimetry in nuclear medicine. (6th December 2021)
- Record Type:
- Journal Article
- Title:
- Review of extremity dosimetry in nuclear medicine. (6th December 2021)
- Main Title:
- Review of extremity dosimetry in nuclear medicine
- Authors:
- Kollaard, Robert
Zorz, Alessandra
Dabin, Jérémie
Covens, Peter
Cooke, Jennie
Crabbé, Melissa
Cunha, Lidia
Dowling, Anita
Ginjaume, Mercè
McNamara, Leanne - Abstract:
- Abstract: The exposure of the fingers is one of the major radiation protection concerns in nuclear medicine (NM). The purpose of this paper is to provide an overview of the exposure, dosimetry and protection of the extremities in NM. A wide range of reported finger doses were found in the literature. Historically, the highest finger doses are found at the fingertip in the preparation and dispensing of 18 F for diagnostic procedures and 90 Y for therapeutic procedures. Doses can be significantly reduced by following recommendations on source shielding, increasing distance and training. Additionally, important trends contributing to a lower dose to the fingers are the use of automated procedures (especially for positron emission tomography (PET)) and the use of prefilled syringes. On the other hand, the workload of PET procedures has substantially increased during the last ten years. In many cases, the accuracy of dose assessment is limited by the location of the dosimeter at the base of the finger and the maximum dose at the fingertip is underestimated (typical dose ratios between 1.4 and 7). It should also be noted that not all dosimeters are sensitive to low-energy beta particles and there is a risk for underestimation of the finger dose when the detector or its filter is too thick. While substantial information has been published on the most common procedures (using 99m Tc, 18 F and 90 Y), less information is available for more recent applications, such as the use of 68 GaAbstract: The exposure of the fingers is one of the major radiation protection concerns in nuclear medicine (NM). The purpose of this paper is to provide an overview of the exposure, dosimetry and protection of the extremities in NM. A wide range of reported finger doses were found in the literature. Historically, the highest finger doses are found at the fingertip in the preparation and dispensing of 18 F for diagnostic procedures and 90 Y for therapeutic procedures. Doses can be significantly reduced by following recommendations on source shielding, increasing distance and training. Additionally, important trends contributing to a lower dose to the fingers are the use of automated procedures (especially for positron emission tomography (PET)) and the use of prefilled syringes. On the other hand, the workload of PET procedures has substantially increased during the last ten years. In many cases, the accuracy of dose assessment is limited by the location of the dosimeter at the base of the finger and the maximum dose at the fingertip is underestimated (typical dose ratios between 1.4 and 7). It should also be noted that not all dosimeters are sensitive to low-energy beta particles and there is a risk for underestimation of the finger dose when the detector or its filter is too thick. While substantial information has been published on the most common procedures (using 99m Tc, 18 F and 90 Y), less information is available for more recent applications, such as the use of 68 Ga for PET imaging. Also, there is a need for continuous awareness with respect to contamination of the fingers, as this factor can contribute substantially to the finger dose. … (more)
- Is Part Of:
- Journal of radiological protection. Volume 41:Number 4(2021)
- Journal:
- Journal of radiological protection
- Issue:
- Volume 41:Number 4(2021)
- Issue Display:
- Volume 41, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 41
- Issue:
- 4
- Issue Sort Value:
- 2021-0041-0004-0000
- Page Start:
- R60
- Page End:
- R87
- Publication Date:
- 2021-12-06
- Subjects:
- nuclear medicine -- extremity dosimetry -- skin dose -- finger dose -- individual monitoring -- contamination
Radiation -- Safety measures -- Periodicals
Health Physics -- Periodicals
Radiation Monitoring -- Periodicals
Radiation Protection -- Periodicals
Rayonnement -- Sécurité -- Mesures -- Périodiques
Electronic journals
Fulltext
Internet Resource
Periodical
363.179905 - Journal URLs:
- http://www.iop.org/EJ/journal/JRP ↗
http://iopscience.iop.org/0952-4746/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1361-6498/ac31a2 ↗
- Languages:
- English
- ISSNs:
- 0952-4746
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20002.xml