Repeated echocardiographic imaging of aortic stenosis: Real‐life lessons. Issue 11 (30th October 2021)
- Record Type:
- Journal Article
- Title:
- Repeated echocardiographic imaging of aortic stenosis: Real‐life lessons. Issue 11 (30th October 2021)
- Main Title:
- Repeated echocardiographic imaging of aortic stenosis: Real‐life lessons
- Authors:
- Bray, Jonathan J. H.
Ionescu, Adrian - Abstract:
- Abstract: Background: Timing of aortic valve intervention is dependent on the accuracy and reproducibility of echocardiographic (ECHO) parameters. We aimed to assess haemodynamic subsets of aortic stenosis (AS), their change over time, and variability of ECHO parameters. Method: This retrospective, longitudinal study compared sequential ECHO over 15 months to identify concordant or discordant aortic valve area (AVA) and mean pressure gradient (MPG) in order to determine the real world variability of echocardiographic indices. Results: We included 143 patients with a mean age of 76.0 years. The median length of time between studies was 112 days (IQR 38–208). Initially, participants were classified as 9 (6.4%) mild, 47 (33.6%) moderate, and 84 (60.0%%) severe AS. In 80 (55.9%) AVA and MPG were concordant; stroke volume index (SVi) was < 35 mL/m 2 in 53 (74.6%). AS severity was downgraded in 29 (20.7%) patients. MPG was most consistent and AVA was the least consistent between successive investigations (intraclass correlation coefficients R = .86 and R = .76, respectively). Even small variations in left ventricular outflow tract (LVOT) measurement of 1 standard deviation reclassified up to 67% of participants from severe to non‐severe. Conclusion: Almost half of patients with AS have valve area/gradient discordance. Variations in LVOT diameter measurement commensurate with clinical practice reclassified AS severity in up to two‐third of cases. Change in AS severity should onlyAbstract: Background: Timing of aortic valve intervention is dependent on the accuracy and reproducibility of echocardiographic (ECHO) parameters. We aimed to assess haemodynamic subsets of aortic stenosis (AS), their change over time, and variability of ECHO parameters. Method: This retrospective, longitudinal study compared sequential ECHO over 15 months to identify concordant or discordant aortic valve area (AVA) and mean pressure gradient (MPG) in order to determine the real world variability of echocardiographic indices. Results: We included 143 patients with a mean age of 76.0 years. The median length of time between studies was 112 days (IQR 38–208). Initially, participants were classified as 9 (6.4%) mild, 47 (33.6%) moderate, and 84 (60.0%%) severe AS. In 80 (55.9%) AVA and MPG were concordant; stroke volume index (SVi) was < 35 mL/m 2 in 53 (74.6%). AS severity was downgraded in 29 (20.7%) patients. MPG was most consistent and AVA was the least consistent between successive investigations (intraclass correlation coefficients R = .86 and R = .76, respectively). Even small variations in left ventricular outflow tract (LVOT) measurement of 1 standard deviation reclassified up to 67% of participants from severe to non‐severe. Conclusion: Almost half of patients with AS have valve area/gradient discordance. Variations in LVOT diameter measurement commensurate with clinical practice reclassified AS severity in up to two‐third of cases. Change in AS severity should only be accepted following careful scrutiny of all available ECHO data. … (more)
- Is Part Of:
- Echocardiography. Volume 38:Issue 11(2021)
- Journal:
- Echocardiography
- Issue:
- Volume 38:Issue 11(2021)
- Issue Display:
- Volume 38, Issue 11 (2021)
- Year:
- 2021
- Volume:
- 38
- Issue:
- 11
- Issue Sort Value:
- 2021-0038-0011-0000
- Page Start:
- 1854
- Page End:
- 1859
- Publication Date:
- 2021-10-30
- Subjects:
- 2D echocardiography -- accuracy -- aortic stenosis -- haemodynamic subsets
Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.15222 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20015.xml