Comparing deep learning-based automatic segmentation of breast masses to expert interobserver variability in ultrasound imaging. (December 2021)
- Record Type:
- Journal Article
- Title:
- Comparing deep learning-based automatic segmentation of breast masses to expert interobserver variability in ultrasound imaging. (December 2021)
- Main Title:
- Comparing deep learning-based automatic segmentation of breast masses to expert interobserver variability in ultrasound imaging
- Authors:
- Webb, Jeremy M.
Adusei, Shaheeda A.
Wang, Yinong
Samreen, Naziya
Adler, Kalie
Meixner, Duane D.
Fazzio, Robert T.
Fatemi, Mostafa
Alizad, Azra - Abstract:
- Abstract: Deep learning is a powerful tool that became practical in 2008, harnessing the power of Graphic Processing Unites, and has developed rapidly in image, video, and natural language processing. There are ongoing developments in the application of deep learning to medical data for a variety of tasks across multiple imaging modalities. The reliability and repeatability of deep learning techniques are of utmost importance if deep learning can be considered a tool for assisting experts, including physicians, radiologists, and sonographers. Owing to the high costs of labeling data, deep learning models are often evaluated against one expert, and it is unknown if any errors fall within a clinically acceptable range. Ultrasound is a commonly used imaging modality for breast cancer screening processes and for visually estimating risk using the Breast Imaging Reporting and Data System score. This process is highly dependent on the skills and experience of the sonographers and radiologists, thereby leading to interobserver variability and interpretation. For these reasons, we propose an interobserver reliability study comparing the performance of a current top-performing deep learning segmentation model against three experts who manually segmented suspicious breast lesions in clinical ultrasound (US) images. We pretrained the model using a US thyroid segmentation dataset with 455 patients and 50, 993 images, and trained the model using a US breast segmentation dataset with 733Abstract: Deep learning is a powerful tool that became practical in 2008, harnessing the power of Graphic Processing Unites, and has developed rapidly in image, video, and natural language processing. There are ongoing developments in the application of deep learning to medical data for a variety of tasks across multiple imaging modalities. The reliability and repeatability of deep learning techniques are of utmost importance if deep learning can be considered a tool for assisting experts, including physicians, radiologists, and sonographers. Owing to the high costs of labeling data, deep learning models are often evaluated against one expert, and it is unknown if any errors fall within a clinically acceptable range. Ultrasound is a commonly used imaging modality for breast cancer screening processes and for visually estimating risk using the Breast Imaging Reporting and Data System score. This process is highly dependent on the skills and experience of the sonographers and radiologists, thereby leading to interobserver variability and interpretation. For these reasons, we propose an interobserver reliability study comparing the performance of a current top-performing deep learning segmentation model against three experts who manually segmented suspicious breast lesions in clinical ultrasound (US) images. We pretrained the model using a US thyroid segmentation dataset with 455 patients and 50, 993 images, and trained the model using a US breast segmentation dataset with 733 patients and 29, 884 images. We found a mean Fleiss kappa value of 0.78 for the performance of three experts in breast mass segmentation compared to a mean Fleiss kappa value of 0.79 for the performance of experts and the optimized deep learning model. Graphical abstract: Image 1 Highlights: Automatic breast mass segmentation statistical performance was on par with that of human expert. Proposed Model had a mean Dice coefficient comparable to that of human expert. Proposed Model had a mean Hausdorff distance comparable to that of human expert. Proposed a focal Matthew's correlation coefficient for loss function. … (more)
- Is Part Of:
- Computers in biology and medicine. Volume 139(2021)
- Journal:
- Computers in biology and medicine
- Issue:
- Volume 139(2021)
- Issue Display:
- Volume 139, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 139
- Issue:
- 2021
- Issue Sort Value:
- 2021-0139-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-12
- Subjects:
- Deep leaning -- Breast cancer -- Automatic segmentation -- Interobserver variability -- Ultrasound
Medicine -- Data processing -- Periodicals
Biology -- Data processing -- Periodicals
610.285 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00104825/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.compbiomed.2021.104966 ↗
- Languages:
- English
- ISSNs:
- 0010-4825
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20001.xml