Development and reliability of a new system for bedside evaluation of non-volitional knee extension force. (December 2021)
- Record Type:
- Journal Article
- Title:
- Development and reliability of a new system for bedside evaluation of non-volitional knee extension force. (December 2021)
- Main Title:
- Development and reliability of a new system for bedside evaluation of non-volitional knee extension force
- Authors:
- Vaz, Marco Aurélio
Fröhlich, Matias
Júnior, Danton Pereira da Silva
Schildt, Alessandro
Thomé, Paulo Ricardo Oppermann
Muller, André Frotta
Tondin, Bruno Rodriguez
Sbruzzi, Graciele
Maffiuletti, Nicola Angelo
Sanches, Paulo Roberto Stefani - Abstract:
- Highlights: NMES therapy counteracts skeletal muscles' disuse effects in clinical settings. The NMES-dynamometer system allows for knee extensors evaluation/stimulation. The system is reliable if used by different raters or same rater on different days. The system is clinically safe to mechanically load knee extensor muscles. The system may reduce muscle atrophy that occurs during bed-rest conditions. Abstract: Purpose: Neuromuscular electrical stimulation (NMES) is a widely-used technique for diagnostic and therapeutic purposes. Here we developed and tested the reliability of a new NMES-dynamometer system for bedside evaluation of knee extensor muscle function. Materials and methods: Thirty-two healthy participants (16 men, 16 women; 27±5 years) completed two testing sessions, 7 days apart. On day 1, a single experienced rater, who repeated the evaluation on day 2 with two other raters, completed a standardized testing procedure. Participants were placed supine, with knees flexed and legs connected to the dynamometer. Maximal voluntary knee extensor isometric force (MVF) and supramaximal twitch force (TwF) were obtained. Results: High intra-rater intraclass correlation coefficients were observed for both MVF (0.91) and TwF (0.94). MVF and TwF standard error of measurements (8.2%, 5.9%) and minimal detectable changes (16%, 11.6%) were low compared to mean values. High intraclass correlation coefficients were also observed for inter-rater comparisons of MVF (0.89) and TwFHighlights: NMES therapy counteracts skeletal muscles' disuse effects in clinical settings. The NMES-dynamometer system allows for knee extensors evaluation/stimulation. The system is reliable if used by different raters or same rater on different days. The system is clinically safe to mechanically load knee extensor muscles. The system may reduce muscle atrophy that occurs during bed-rest conditions. Abstract: Purpose: Neuromuscular electrical stimulation (NMES) is a widely-used technique for diagnostic and therapeutic purposes. Here we developed and tested the reliability of a new NMES-dynamometer system for bedside evaluation of knee extensor muscle function. Materials and methods: Thirty-two healthy participants (16 men, 16 women; 27±5 years) completed two testing sessions, 7 days apart. On day 1, a single experienced rater, who repeated the evaluation on day 2 with two other raters, completed a standardized testing procedure. Participants were placed supine, with knees flexed and legs connected to the dynamometer. Maximal voluntary knee extensor isometric force (MVF) and supramaximal twitch force (TwF) were obtained. Results: High intra-rater intraclass correlation coefficients were observed for both MVF (0.91) and TwF (0.94). MVF and TwF standard error of measurements (8.2%, 5.9%) and minimal detectable changes (16%, 11.6%) were low compared to mean values. High intraclass correlation coefficients were also observed for inter-rater comparisons of MVF (0.89) and TwF (0.86). Standard errors of measurements (MVF: 8.7%, TwF: 5.5%) and minimal detectable changes (MVF: 17.2%, TwF: 10.8%) were similar to intra-rater comparisons. Conclusion: The good reliability of the novel NMES-dynamometer system suggests it as an appropriate tool for the bedside evaluation of knee extensor muscle function. … (more)
- Is Part Of:
- Medical engineering & physics. Volume 98(2021)
- Journal:
- Medical engineering & physics
- Issue:
- Volume 98(2021)
- Issue Display:
- Volume 98, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 98
- Issue:
- 2021
- Issue Sort Value:
- 2021-0098-2021-0000
- Page Start:
- 28
- Page End:
- 35
- Publication Date:
- 2021-12
- Subjects:
- Dynamometry -- Inter-rater -- Intra-rater -- Neuromuscular electrical stimulation -- Knee extension
Biomedical engineering -- Periodicals
Biomedical Engineering -- Periodicals
Physics -- Periodicals
Génie biomédical -- Périodiques
Biomedical engineering
Electronic journals
Periodicals
610.28 - Journal URLs:
- http://www.medengphys.com ↗
http://www.sciencedirect.com/science/journal/13504533 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13504533 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13504533 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.medengphy.2021.10.007 ↗
- Languages:
- English
- ISSNs:
- 1350-4533
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5527.323000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20012.xml