- Abstract: In this work, hemodynamic alterations in a patient-specific, heavily calcified coronary artery following stent deployment and post-dilations are quantified using in silico and ex-vivo approaches. Three-dimensional artery models were reconstructed from OCT images. Stent deployment and post-dilation with various inflation pressures were performed through both the finite element method (FEM) and ex vivo experiments. Results from FEM agreed very well with the ex-vivo measurements, interms of lumen areas, stent underexpansion, and strut malapposition. In addition, computational fluid dynamics (CFD) simulations were performed to delineate the hemodynamic alterations after stent deployment and post-dilations. A pressure time history at the inlet and a lumped parameter model (LPM) at the outlet were adopted to mimic the aortic pressure and the distal arterial tree, respectively. The pressure drop across the lesion, pertaining to the clinical measure of instantaneous wave-free flow ratio (iFR), was investigated. Results have shown that post-dilations are necessary for the lumen gain as well as the hemodynamic restoration towards hemostasis. Malapposed struts induced much higher shear rate, flow disturbances and lower time-averaged wall shear stress (TAWSS) around struts. Post-dilations mitigated the strut malapposition, and thus the shear rate. Moreover, stenting induced larger area of low TAWSS (<0.4 Pa) and lager volume of high shear rate (>2000 s −1 ), indicating higherAbstract: In this work, hemodynamic alterations in a patient-specific, heavily calcified coronary artery following stent deployment and post-dilations are quantified using in silico and ex-vivo approaches. Three-dimensional artery models were reconstructed from OCT images. Stent deployment and post-dilation with various inflation pressures were performed through both the finite element method (FEM) and ex vivo experiments. Results from FEM agreed very well with the ex-vivo measurements, interms of lumen areas, stent underexpansion, and strut malapposition. In addition, computational fluid dynamics (CFD) simulations were performed to delineate the hemodynamic alterations after stent deployment and post-dilations. A pressure time history at the inlet and a lumped parameter model (LPM) at the outlet were adopted to mimic the aortic pressure and the distal arterial tree, respectively. The pressure drop across the lesion, pertaining to the clinical measure of instantaneous wave-free flow ratio (iFR), was investigated. Results have shown that post-dilations are necessary for the lumen gain as well as the hemodynamic restoration towards hemostasis. Malapposed struts induced much higher shear rate, flow disturbances and lower time-averaged wall shear stress (TAWSS) around struts. Post-dilations mitigated the strut malapposition, and thus the shear rate. Moreover, stenting induced larger area of low TAWSS (<0.4 Pa) and lager volume of high shear rate (>2000 s −1 ), indicating higher risks of in-stent restenosis (ISR) and stent thrombosis (ST), respectively. Oscillatory shear index (OSI) and relative residence time (RRT) indicated the wall regions more prone to ISR are located near the malapposed stent struts. Highlights: CFD, integrated with FEM, were adopted to study the hemodynamic alternations following stenting and post-dilations. Pulsatile blood flow is modeled in CFD simulation by employing a Windkessel type boundary condition at the distal end. The iFR analysis demonstrated the efficacy of post-dilations in a heavily calcified coronary artery. TAWSS, OSI, and RRT indicated atherogenic hemodynamic conditions on the wall regions located near the malapposed stent struts. … (more)
- Is Part Of:
- Computers in biology and medicine. Volume 139(2021)
- Journal:
- Computers in biology and medicine
- Issue:
- Volume 139(2021)
- Issue Display:
- Volume 139, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 139
- Issue:
- 2021
- Issue Sort Value:
- 2021-0139-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-12
- Subjects:
- Hemodynamics -- Stent expansion -- Post-dilation -- Calcified artery -- Wall shear stress -- Oscillatory shear index -- Relative residence time -- Shear rate -- Stent thrombosis -- Restenosis -- Computational fluid dynamics (CFD) -- Finite element method (FEM) -- Percutaneous coronary intervention (PCI) -- Optical coherence tomography (OCT)
Medicine -- Data processing -- Periodicals
Biology -- Data processing -- Periodicals
610.285 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00104825/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.compbiomed.2021.104962 ↗
- Languages:
- English
- ISSNs:
- 0010-4825
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20001.xml