Prospective evaluation of radiation dose with conventional fluoroscopic voiding cystourethrogram in pediatric patients. Issue 6 (December 2021)
- Record Type:
- Journal Article
- Title:
- Prospective evaluation of radiation dose with conventional fluoroscopic voiding cystourethrogram in pediatric patients. Issue 6 (December 2021)
- Main Title:
- Prospective evaluation of radiation dose with conventional fluoroscopic voiding cystourethrogram in pediatric patients
- Authors:
- Chaudhry, Rajeev
Dangle, Pankaj P.
Cannon, Glenn M.
Schneck, Francis X.
Stephany, Heidi A. - Abstract:
- Summary: Introduction: Skin entrance doses for voiding cystourethrogram (VCUG) have not been well characterized in the literature. Radiation exposure is measured as either dose area product (DAP) or air kerma, which estimates the effective dose, but does not accurately reflect absorbed dose at skin level. Objective: The objective of this study was to measure the skin entrance dose during fluoroscopic VCUG study in pediatric patients using single point dosimeters. Study design: Pediatric patients undergoing fluoroscopic VCUG were prospectively enrolled in our study. Landauer NanoDot™OSLD dosimeters were affixed to the skin overlying the sacrum to measure skin entrance dose. The fluoroscopic unit was set to the following parameters: low dose setting, skin-to-source distance of 54 cm, pulsed fluoroscopy at 3 frames/sec. Results: Forty-four patients with a median age of 13.6 months (IQR 3.7–42.3) were enrolled. Median fluoroscopic time was 54 s (IQR 36–72). The median values absorbed dose by dosimeter and air kerma were 0.32 mGy (IQR 0.13–0.56, range 0.01–2.9) and 0.24 mGy (IQR 0.14–0.37), respectively. There was a positive correlation between the air kerma and absorbed dose (r = 0.69, p < 0.001) and fluoroscopy time and absorbed dose mGy (r = 0.60, p < 0.001). Absorbed dose was independent of age, body mass index and body surface area (p = 0.19, p = 0.57 and p = 0.16, respectively). Median whole body effective dose was 0.04 mSv (IQR 0.02–0.7). Discussion: Overall, the absorbedSummary: Introduction: Skin entrance doses for voiding cystourethrogram (VCUG) have not been well characterized in the literature. Radiation exposure is measured as either dose area product (DAP) or air kerma, which estimates the effective dose, but does not accurately reflect absorbed dose at skin level. Objective: The objective of this study was to measure the skin entrance dose during fluoroscopic VCUG study in pediatric patients using single point dosimeters. Study design: Pediatric patients undergoing fluoroscopic VCUG were prospectively enrolled in our study. Landauer NanoDot™OSLD dosimeters were affixed to the skin overlying the sacrum to measure skin entrance dose. The fluoroscopic unit was set to the following parameters: low dose setting, skin-to-source distance of 54 cm, pulsed fluoroscopy at 3 frames/sec. Results: Forty-four patients with a median age of 13.6 months (IQR 3.7–42.3) were enrolled. Median fluoroscopic time was 54 s (IQR 36–72). The median values absorbed dose by dosimeter and air kerma were 0.32 mGy (IQR 0.13–0.56, range 0.01–2.9) and 0.24 mGy (IQR 0.14–0.37), respectively. There was a positive correlation between the air kerma and absorbed dose (r = 0.69, p < 0.001) and fluoroscopy time and absorbed dose mGy (r = 0.60, p < 0.001). Absorbed dose was independent of age, body mass index and body surface area (p = 0.19, p = 0.57 and p = 0.16, respectively). Median whole body effective dose was 0.04 mSv (IQR 0.02–0.7). Discussion: Overall, the absorbed dose received by the dosimeter remained low at a median of 0.32 mGy (range 0.01–2.91). These values are remarkably low and well within the accepted radiation exposure norms. Our radiologists follow a strict protocol to reduce the overall radiation emitted during a VCUG. These measures include setting the x-ray source at a low dose mode, collimating to the smallest area possible, and using pulsed fluoroscopy at 3 frames/sec. Limitations to this study include a slight variability in technique of VCUG between different technicians and providers, for which we cannot control. Conclusion: The radiation dose absorbed at the skin entrance and uniform whole body effective dose is low for a single VCUG when utilizing strict parameters. While newer non-ionizing technologies continue to emerge, our data is encouraging and will serve as a valuable tool when educating parents regarding radiation doses associated with a VCUG. Summary Table Radiographic parameters with VCUG measuring dose area product, air Kerma, dose absorbed at skin level and effective dose. Summary Table Mean Median Fluoro time (sec) 55.6 ± 29.6 54 (IQR 36–79.8) Dose area product (mGy∗m 2 ) 12.8 ± 22.7 5.3 (IQR 3.1–8.3) Air Kerma (mGy) 0.57 ± 1.0 0.24 (IQR 0.14–0.37) Dose absorbed (mGy) 0.55 ± 0.66 0.32 (IQR 0.13–0.56) Effective dose (mSv) – whole body 0.09 ± 0.20 0.04 (IQR 0.02–0.07) … (more)
- Is Part Of:
- Journal of pediatric urology. Volume 17:Issue 6(2021)
- Journal:
- Journal of pediatric urology
- Issue:
- Volume 17:Issue 6(2021)
- Issue Display:
- Volume 17, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 17
- Issue:
- 6
- Issue Sort Value:
- 2021-0017-0006-0000
- Page Start:
- 790.e1
- Page End:
- 790.e5
- Publication Date:
- 2021-12
- Subjects:
- Radiation exposure -- Voiding cystourethrogram -- Pediatrics -- Vesicoureteral reflux
mGy milliGray -- mSv milliSievert -- VCUG voiding cystourethrogram -- VUR vesicoureteral reflux -- BMI body mass index -- BSA body surface area -- DAP dose area product
Pediatric urology -- Periodicals
Urologic Diseases -- Periodicals
Urogenital Diseases -- Periodicals
Urologic Surgical Procedures -- Periodicals
Child
Infant
Urologie pédiatrique -- Périodiques
Appareil urinaire -- Maladies -- Périodiques
Pédiatrie
Urologie
Pediatric urology
Périodique électronique (Descripteur de forme)
Ressource Internet (Descripteur de forme)
Electronic journals
Periodicals
Electronic journals
618.926 - Journal URLs:
- http://www.sciencedirect.com/science/journal/14775131 ↗
http://www.sciencedirect.com/science/journal/14775131 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jpurol.2021.09.010 ↗
- Languages:
- English
- ISSNs:
- 1477-5131
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5030.285000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20012.xml