Validity and reliability of a player-tracking device to identify movement orientation in team sports. (3rd September 2021)
- Record Type:
- Journal Article
- Title:
- Validity and reliability of a player-tracking device to identify movement orientation in team sports. (3rd September 2021)
- Main Title:
- Validity and reliability of a player-tracking device to identify movement orientation in team sports
- Authors:
- Tan, Justin H.Y.
Polglaze, Ted
Peeling, Peter - Abstract:
- ABSTRACT: The purpose of this study was to determine the validity and reliability of the GPExe pro2 device to identify movement orientation in team-sport locomotion. Part A involved a series of discrete movement tasks of varying direction and orientation at two speeds (walk, run); Part B involved a continuous Simulated Game Circuit (SGC). For validity, distance in each orientation quadrant (forward, backward, left, right) and two aggregated sectors (lateral, non-forward), was compared to the known distance and calculated as the standard error of estimate (SEE). Inter-unit reliability was assessed in the SGC and reported as typical error (TE) and coefficient of variation (CV). In total, 256 trials were collected for validity (Part A 232, Part B 24), and 17 trials for reliability. Validity improved with faster and more continuous movement (SEE: walk 6.2–8.7%; run 4.4–8.2%; SGC 1.0–6.2%), was better for forward and backward (1.0–2.8%) compared to left and right orientation (3.8–6.2%), and for aggregated sectors (2.4–5.1%) rather than specific quadrants. Reliability was good (CV<5%) for forward and backward quadrants and both aggregated sectors, but poor (CV>10%) for left and right quadrants. These devices provide valid and reliable movement orientation data for team-sport locomotion, particularly in differentiating between forward and non-forward movement.
- Is Part Of:
- International journal of performance analysis in sport. Volume 21:Number 5(2021)
- Journal:
- International journal of performance analysis in sport
- Issue:
- Volume 21:Number 5(2021)
- Issue Display:
- Volume 21, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 21
- Issue:
- 5
- Issue Sort Value:
- 2021-0021-0005-0000
- Page Start:
- 790
- Page End:
- 803
- Publication Date:
- 2021-09-03
- Subjects:
- Forward -- backward -- lateral -- magnetometer -- gyroscope -- gps
Sports sciences -- Periodicals
Sports -- Physiological aspects -- Periodicals
796.015 - Journal URLs:
- http://www.tandfonline.com/ ↗
http://www.tandfonline.com/toc/rpan20/current ↗ - DOI:
- 10.1080/24748668.2021.1945881 ↗
- Languages:
- English
- ISSNs:
- 2474-8668
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19971.xml