ICD shocks and complications in patients with inherited arrhythmia syndromes. (December 2021)
- Record Type:
- Journal Article
- Title:
- ICD shocks and complications in patients with inherited arrhythmia syndromes. (December 2021)
- Main Title:
- ICD shocks and complications in patients with inherited arrhythmia syndromes
- Authors:
- Siskin, Matthew
Cerrone, Marina
Shokr, Mohamed
Aizer, Anthony
Barbhaiya, Chirag
Dai, Matthew
Bernstein, Scott
Holmes, Douglas
Knotts, Robert
Park, David S.
Spinelli, Michael
Chinitz, Larry A.
Jankelson, Lior - Abstract:
- Abstract: Background: There is limited information on the long-term outcomes of ICDs in patients with inherited arrhythmia syndromes. Methods: Prospective registry study of inherited arrhythmia patients with an ICD. Incidence of therapies and complications were measured as 5-year cumulative incidence proportions and analyzed with the Kaplan-Meier method. Incidence was compared by device indication, diagnosis type and device type. Cox-regression analysis was used to identify predictors of appropriate shock and device complication. Results: 123 patients with a mean follow up of 6.4 ± 4.8 years were included. The incidence of first appropriate shock was 56.52% vs 24.44%, p < 0.05 for cardiomyopathy and channelopathy patients, despite similar ejection fraction (61% vs 60%, p = 0.6). The incidence of first inappropriate shock was 13.46% vs 56.25%, p < 0.01 for single vs. multi-lead devices. The incidence of first lead complication was higher for multi-lead vs. single lead devices, 43.75% vs. 17.31%, p = 0.04. Patients with an ICD for secondary prevention were more likely to receive an appropriate shock than those with primary prevention indication (HR 2.21, CI 1.07–4.56, p = 0.03). Multi-lead devices were associated with higher risk of inappropriate shock (HR 3.99, CI 1.27–12.52, p = 0.02), with similar appropriate shock risk compared to single lead devices. In 26.5% of patients with dual chamber devices, atrial sensing or pacing was not utilized. Conclusion: The rate ofAbstract: Background: There is limited information on the long-term outcomes of ICDs in patients with inherited arrhythmia syndromes. Methods: Prospective registry study of inherited arrhythmia patients with an ICD. Incidence of therapies and complications were measured as 5-year cumulative incidence proportions and analyzed with the Kaplan-Meier method. Incidence was compared by device indication, diagnosis type and device type. Cox-regression analysis was used to identify predictors of appropriate shock and device complication. Results: 123 patients with a mean follow up of 6.4 ± 4.8 years were included. The incidence of first appropriate shock was 56.52% vs 24.44%, p < 0.05 for cardiomyopathy and channelopathy patients, despite similar ejection fraction (61% vs 60%, p = 0.6). The incidence of first inappropriate shock was 13.46% vs 56.25%, p < 0.01 for single vs. multi-lead devices. The incidence of first lead complication was higher for multi-lead vs. single lead devices, 43.75% vs. 17.31%, p = 0.04. Patients with an ICD for secondary prevention were more likely to receive an appropriate shock than those with primary prevention indication (HR 2.21, CI 1.07–4.56, p = 0.03). Multi-lead devices were associated with higher risk of inappropriate shock (HR 3.99, CI 1.27–12.52, p = 0.02), with similar appropriate shock risk compared to single lead devices. In 26.5% of patients with dual chamber devices, atrial sensing or pacing was not utilized. Conclusion: The rate of appropriate therapies and ICD complications in patients with inherited arrhythmia is high, particularly in cardiomyopathies with multi-lead devices. Risk-benefit ratio should be carefully considered when assessing the indication and type of device in this population. … (more)
- Is Part Of:
- IJC heart & vasculature. Volume 37(2021)
- Journal:
- IJC heart & vasculature
- Issue:
- Volume 37(2021)
- Issue Display:
- Volume 37, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 37
- Issue:
- 2021
- Issue Sort Value:
- 2021-0037-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-12
- Subjects:
- Inherited Arrhythmia -- Cardiac Defibrillator -- Cardiomyopathy -- Channelopathy
Cardiovascular system -- Diseases -- Periodicals
Cardiovascular system -- Pathophysiology -- Periodicals
616.1005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23529067/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.ijcha.2021.100908 ↗
- Languages:
- English
- ISSNs:
- 2352-9067
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19970.xml