Development and performance evaluation of a multi‐layer boron‐lined detector for the CPHS‐SANS instrument. Issue 6 (16th November 2021)
- Record Type:
- Journal Article
- Title:
- Development and performance evaluation of a multi‐layer boron‐lined detector for the CPHS‐SANS instrument. Issue 6 (16th November 2021)
- Main Title:
- Development and performance evaluation of a multi‐layer boron‐lined detector for the CPHS‐SANS instrument
- Authors:
- Jiang, Zhigang
Gong, Hui
Li, Jianmin
Wang, Xuewu
Wang, Yongqiang - Abstract:
- Abstract : A position‐sensitive thermal neutron detector module which is based on multi‐layer boron‐lined tubes has been developed for the CPHS‐SANS instrument. Several aspects of the detector module have been evaluated by simulation and experiment. Abstract : A position‐sensitive thermal neutron detector module based on multi‐layer boron‐lined tubes has been developed. It is designed for the CPHS (compact pulsed hadron source) SANS (small‐angle neutron scattering) instrument [Loong et al. (2012). Phys. Procedia, 26, 8–18]. The detector module consists of 64 boron‐lined tubes, arranged into an eight row by eight column structure. Several key aspects of the development of the detector prototype are briefly covered, including the detector module structure design, the readout electronic system and the digital filter of neutron waveforms. Preliminary characterization reveals that the detector module could achieve an average axial spatial resolution of 5.62 mm and a good position linearity. The detection efficiency measurement shows that more than 30% efficiency can be achieved for thermal neutrons on the CPHS. A virtual experiment was conducted to evaluate the performance of the multi‐layer boron‐lined tubes in SANS measurement; the effect of inside detector scattering of the multi‐layer detector was simulated. The result shows that, by implementing proper data reduction, the impact of inside detector scattering on the Q (momentum transfer) value and Q resolution is negligible.
- Is Part Of:
- Journal of applied crystallography. Volume 54:Issue 6(2021)
- Journal:
- Journal of applied crystallography
- Issue:
- Volume 54:Issue 6(2021)
- Issue Display:
- Volume 54, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 54
- Issue:
- 6
- Issue Sort Value:
- 2021-0054-0006-0000
- Page Start:
- 1738
- Page End:
- 1746
- Publication Date:
- 2021-11-16
- Subjects:
- CPHS‐SANS -- boron‐lined tubes -- spatial resolution -- virtual experiments -- inside detector scattering
Crystallography -- Periodicals
548.05 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://journals.iucr.org/j/journalhomepage.html ↗
http://www-us.ebsco.com/online/direct.asp?JournalID=105188 ↗
http://www.blackwell-synergy.com/loi/jcr ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=jcr&open=2004#C2004 ↗
http://onlinelibrary.wiley.com/journal/10.1107/S16005767 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1107/S1600576721010025 ↗
- Languages:
- English
- ISSNs:
- 0021-8898
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4942.400000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19969.xml