A three-dimensional measurement based on CT for the posterior tilt with ideal inter-and intra-observer reliability in non-displaced femoral neck fractures. Issue 16 (6th December 2021)
- Record Type:
- Journal Article
- Title:
- A three-dimensional measurement based on CT for the posterior tilt with ideal inter-and intra-observer reliability in non-displaced femoral neck fractures. Issue 16 (6th December 2021)
- Main Title:
- A three-dimensional measurement based on CT for the posterior tilt with ideal inter-and intra-observer reliability in non-displaced femoral neck fractures
- Authors:
- Wu, Shenghui
Wang, Wei
Zhang, Binbin
Zhang, Haowei
Xu, Xinsheng
Li, Guangyi
Shi, Huipeng
Mei, Jiong - Abstract:
- Abstract: Posterior tilt is associated with prognosis of non-displaced femoral neck fractures (FNFs). Knowledge of their association is critical and informs surgeons whether to choose internal fixation or arthroplasty in treatment of non-displaced FNFs. This study aimed to design a novel three-dimensional (3D) posterior tilt measurement and evaluate the intra- and inter-observer variability compared to two-dimensional (2D) measurement proposed by Palm. We hypothesized that 3D measurement would be more accurate and realistic with higher reliability. To test the hypothesis, three observers measured the posterior tilt on the radiographs of 50 non-displaced FNFs, twice with both methods. Intra- and inter-observer reliability for each measurement method used were determined. The measured angle was divided into two categories, at the cut-off of 20° for clinical practice simulation. Intra- and inter-observer reliability were identified for clinical effectiveness. The results indicated that inter- and intra-observer reliability for 3D measurement and its classification was almost perfect with an intraclass coefficient of 0.995 (0.994) and a kappa value of 0.927(0.947), respectively. Conversely, a substantial inter- and intra-observer reliability for the 2D measurement was obtained with an interclass coefficient of 0.764 as well as an intraclass coefficient of 0.773. The clinical validity for 2D measurement showed slight inter-reliability and moderate intra-reliability with a kappaAbstract: Posterior tilt is associated with prognosis of non-displaced femoral neck fractures (FNFs). Knowledge of their association is critical and informs surgeons whether to choose internal fixation or arthroplasty in treatment of non-displaced FNFs. This study aimed to design a novel three-dimensional (3D) posterior tilt measurement and evaluate the intra- and inter-observer variability compared to two-dimensional (2D) measurement proposed by Palm. We hypothesized that 3D measurement would be more accurate and realistic with higher reliability. To test the hypothesis, three observers measured the posterior tilt on the radiographs of 50 non-displaced FNFs, twice with both methods. Intra- and inter-observer reliability for each measurement method used were determined. The measured angle was divided into two categories, at the cut-off of 20° for clinical practice simulation. Intra- and inter-observer reliability were identified for clinical effectiveness. The results indicated that inter- and intra-observer reliability for 3D measurement and its classification was almost perfect with an intraclass coefficient of 0.995 (0.994) and a kappa value of 0.927(0.947), respectively. Conversely, a substantial inter- and intra-observer reliability for the 2D measurement was obtained with an interclass coefficient of 0.764 as well as an intraclass coefficient of 0.773. The clinical validity for 2D measurement showed slight inter-reliability and moderate intra-reliability with a kappa value of 0.192 and 0.587, respectively. Hence, the novel 3D measurement appears to be more reliable with a strong inter- and intra-observer reliability measurement. Further clinical studies are needed to carry out to validate this hypothesis. … (more)
- Is Part Of:
- Computer methods in biomechanics and biomedical engineering. Volume 24:Issue 16(2021)
- Journal:
- Computer methods in biomechanics and biomedical engineering
- Issue:
- Volume 24:Issue 16(2021)
- Issue Display:
- Volume 24, Issue 16 (2021)
- Year:
- 2021
- Volume:
- 24
- Issue:
- 16
- Issue Sort Value:
- 2021-0024-0016-0000
- Page Start:
- 1854
- Page End:
- 1861
- Publication Date:
- 2021-12-06
- Subjects:
- Posterior tilt -- non-displaced femoral neck fracture -- computed tomography
Biomechanics -- Data processing -- Periodicals
Biomedical engineering -- Periodicals
Biomechanics -- Periodicals
Biomedical Engineering -- methods -- Periodicals
Computing Methodologies -- Periodicals
612.7 - Journal URLs:
- http://www.tandfonline.com/toc/gcmb20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/10255842.2021.1925256 ↗
- Languages:
- English
- ISSNs:
- 1025-5842
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.100250
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19955.xml