Structural optimization of V-sector valve cores and adaptability in secondary heating networks. (October 2021)
- Record Type:
- Journal Article
- Title:
- Structural optimization of V-sector valve cores and adaptability in secondary heating networks. (October 2021)
- Main Title:
- Structural optimization of V-sector valve cores and adaptability in secondary heating networks
- Authors:
- Jia, Menglin
Li, Zhiwei
Jia, Lizhi
Liu, Junjie - Abstract:
- Abstract: We analyzed the flow characteristics of a control valve in a secondary heating network and combined the optimization of the valve core structure with a method to solve the actual control problem of the secondary heating network. First, according to the common V-sector ball valve core, another three kinds of different V-sector ball valve cores were designed, and a simulation analysis was carried out using CFD software. By comparing the influence of four different valve core opening shapes on the valve flow characteristic curve, it was found that V3 showed better equal percentage characteristics under the opening range of 50%–100%, which improved the flow control accuracy in the heating pipe network that lacked flow feedback, and the accuracy of the simulation results was verified on the test bench. Based on this, in the different branches of the heating secondary network, the opening variation range of the four valves in actual applications were determined, and the opening variation range of the V3 valve was increased by approximately 10%. The analysis results showed that controlling the proportion of the slender part in the opening shape of the spool can effectively increase the opening range of the control valve in practical applications, thereby improving the flow control accuracy of the heating secondary network and reducing the energy consumption of heating regulation. Highlights: Combined the optimization of the valve structure with a method to solve theAbstract: We analyzed the flow characteristics of a control valve in a secondary heating network and combined the optimization of the valve core structure with a method to solve the actual control problem of the secondary heating network. First, according to the common V-sector ball valve core, another three kinds of different V-sector ball valve cores were designed, and a simulation analysis was carried out using CFD software. By comparing the influence of four different valve core opening shapes on the valve flow characteristic curve, it was found that V3 showed better equal percentage characteristics under the opening range of 50%–100%, which improved the flow control accuracy in the heating pipe network that lacked flow feedback, and the accuracy of the simulation results was verified on the test bench. Based on this, in the different branches of the heating secondary network, the opening variation range of the four valves in actual applications were determined, and the opening variation range of the V3 valve was increased by approximately 10%. The analysis results showed that controlling the proportion of the slender part in the opening shape of the spool can effectively increase the opening range of the control valve in practical applications, thereby improving the flow control accuracy of the heating secondary network and reducing the energy consumption of heating regulation. Highlights: Combined the optimization of the valve structure with a method to solve the control problem of the secondary heating network. Optimized spool shows better equal percentage characteristics under the opening range of 50% to 100%. Propose an optimized spool, which improved the flow control accuracy in the heating pipe network that lacked flow feedback. Controlling the proportion of the slender part in the core opening shape can increase the opening range of the control valve. … (more)
- Is Part Of:
- Flow measurement and instrumentation. Volume 81(2021)
- Journal:
- Flow measurement and instrumentation
- Issue:
- Volume 81(2021)
- Issue Display:
- Volume 81, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 81
- Issue:
- 2021
- Issue Sort Value:
- 2021-0081-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10
- Subjects:
- Secondary heating network -- Simulation -- Opening shape -- Opening variation range -- Flow control accuracy
Fluid dynamic measurements -- Periodicals
Flow meters -- Periodicals
Fluides, Dynamique des -- Mesure -- Périodiques
Débitmètres -- Périodiques
681.2805 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09555986 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.flowmeasinst.2021.102032 ↗
- Languages:
- English
- ISSNs:
- 0955-5986
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3958.300000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19959.xml