- Abstract: Objective: To assess the accuracy of a proportion‐corrected radiographic cementless femoral stem level calculation in a cadaver model. Study design: Cadaveric study. Sample population: Twelve cadaveric canine femurs. Methods: Cementless femoral stems were implanted in 12 cadaver femurs at three stem levels. Craniocaudal projection radiographs of the implanted femurs were obtained at 0°, 10°, 20°, 30°, and 45° angulations in the sagittal plane (relative to the radiographic plate) and at 0°, 15°, and 30° internal and external axial rotation. A proportional calculation including actual stem length, radiographically measured stem length, and radiographically measured stem level relative to the greater trochanter (uncorrected stem level) was solved to yield a corrected stem level. The errors of the stem level measurements were compared. Results: With 0° or 15° of internal rotation, the true stem level differed by more than 0.5 mm from corrected stem level in 2 of 30 tested femoral positions. It differed from the uncorrected stem level in 10 of 30 positions. With 15° and 30° external rotation or 30° internal rotation, the corrected stem level was not more accurate than the uncorrected stem level for any femoral position. Conclusion: Use of a proportion correction minimized variability in the stem‐level measurements due to sagittal angulation (up to 30°) of the femur at 0° or 15° of internal rotation. Clinical significance: A proportion correction can improve the accuracyAbstract: Objective: To assess the accuracy of a proportion‐corrected radiographic cementless femoral stem level calculation in a cadaver model. Study design: Cadaveric study. Sample population: Twelve cadaveric canine femurs. Methods: Cementless femoral stems were implanted in 12 cadaver femurs at three stem levels. Craniocaudal projection radiographs of the implanted femurs were obtained at 0°, 10°, 20°, 30°, and 45° angulations in the sagittal plane (relative to the radiographic plate) and at 0°, 15°, and 30° internal and external axial rotation. A proportional calculation including actual stem length, radiographically measured stem length, and radiographically measured stem level relative to the greater trochanter (uncorrected stem level) was solved to yield a corrected stem level. The errors of the stem level measurements were compared. Results: With 0° or 15° of internal rotation, the true stem level differed by more than 0.5 mm from corrected stem level in 2 of 30 tested femoral positions. It differed from the uncorrected stem level in 10 of 30 positions. With 15° and 30° external rotation or 30° internal rotation, the corrected stem level was not more accurate than the uncorrected stem level for any femoral position. Conclusion: Use of a proportion correction minimized variability in the stem‐level measurements due to sagittal angulation (up to 30°) of the femur at 0° or 15° of internal rotation. Clinical significance: A proportion correction can improve the accuracy of femoral stem‐level assessment on craniocaudal projection radiographs, which may aid in the detection of subsidence after cementless total hip replacement. … (more)
- Is Part Of:
- Veterinary surgery. Volume 50:Issue 8(2021)
- Journal:
- Veterinary surgery
- Issue:
- Volume 50:Issue 8(2021)
- Issue Display:
- Volume 50, Issue 8 (2021)
- Year:
- 2021
- Volume:
- 50
- Issue:
- 8
- Issue Sort Value:
- 2021-0050-0008-0000
- Page Start:
- 1592
- Page End:
- 1599
- Publication Date:
- 2021-09-20
- Subjects:
- Veterinary surgery -- Periodicals
Veterinary Medicine -- Periodicals
Surgery -- Periodicals
Societies, Medical -- Periodicals
636.0897 - Journal URLs:
- http://www.blackwell-synergy.com/loi/vsu ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=vsu ↗
http://www.harcourthealth.com/vetsurg ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0161-3499;screen=info;ECOIP ↗ - DOI:
- 10.1111/vsu.13723 ↗
- Languages:
- English
- ISSNs:
- 0161-3499
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9231.037000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19958.xml