Comparative Evaluation of 4-Dimensional Computed Tomography and 4-Dimensional Magnetic Resonance Imaging to Delineate the Target of Primary Liver Cancer. (October 2021)
- Record Type:
- Journal Article
- Title:
- Comparative Evaluation of 4-Dimensional Computed Tomography and 4-Dimensional Magnetic Resonance Imaging to Delineate the Target of Primary Liver Cancer. (October 2021)
- Main Title:
- Comparative Evaluation of 4-Dimensional Computed Tomography and 4-Dimensional Magnetic Resonance Imaging to Delineate the Target of Primary Liver Cancer
- Authors:
- Chen, Yukai
Gong, Guanzhong
Wang, Yinxing
Liu, Chenlu
Su, Ya
Wang, Lizhen
Yang, Bo
Yin, Yong - Abstract:
- Purpose: To evaluate the feasibility of 4-dimensional magnetic resonance imaging (4DMRI) in establishing the target of primary liver cancer in comparison with 4-dimensional computed tomography (4DCT).Methods and Materials: A total of 23 patients with primary liver cancer who received radiotherapy were selected, and 4DCT and T2w-4DMRI simulations were conducted to obtain 4DCT and T2w-4DMRI simulation images. The 4DCT and T2w-4DMRI data were sorted into 10 and 8 respiratory phase bins, respectively. The liver and gross tumor volumes (GTVs) were delineated in all images using programmed clinical workflows under tumor delineation guidelines. The internal organs at risk volumes (IRVs) and internal target volumes (ITVs) were the unions of all the phase livers and GTVs, respectively. Then, the artifacts, liver volume, GTV, and motion range in 4DCT and T2w-4DMRI were compared.Results: The mean GTV volume based on 4DMRI was 136.42 ± 231.27 cm 3, which was 25.04 cm 3 (15.5%) less than that of 4DCT (161.46 ± 280.29 cm 3 ). The average volume of ITV determined by 4DMRI was 166.12 ± 270.43 cm 3, which was 22.44 cm 3 (11.9%) less than that determined by 4DCT (188.56 ± 307.57 cm 3 ). Liver volume and IRV in 4DMRI increased by 4.0% and 6.6%, respectively, compared with 4DCT. The difference in tumor motion by T2w-4DMRI based on the centroid was greater than that of 4DCT in the L/R, A/P, and S/I directions, and the average displacement differences were 2.6, 2.8, and 6.9 mm, respectively. ThePurpose: To evaluate the feasibility of 4-dimensional magnetic resonance imaging (4DMRI) in establishing the target of primary liver cancer in comparison with 4-dimensional computed tomography (4DCT).Methods and Materials: A total of 23 patients with primary liver cancer who received radiotherapy were selected, and 4DCT and T2w-4DMRI simulations were conducted to obtain 4DCT and T2w-4DMRI simulation images. The 4DCT and T2w-4DMRI data were sorted into 10 and 8 respiratory phase bins, respectively. The liver and gross tumor volumes (GTVs) were delineated in all images using programmed clinical workflows under tumor delineation guidelines. The internal organs at risk volumes (IRVs) and internal target volumes (ITVs) were the unions of all the phase livers and GTVs, respectively. Then, the artifacts, liver volume, GTV, and motion range in 4DCT and T2w-4DMRI were compared.Results: The mean GTV volume based on 4DMRI was 136.42 ± 231.27 cm 3, which was 25.04 cm 3 (15.5%) less than that of 4DCT (161.46 ± 280.29 cm 3 ). The average volume of ITV determined by 4DMRI was 166.12 ± 270.43 cm 3, which was 22.44 cm 3 (11.9%) less than that determined by 4DCT (188.56 ± 307.57 cm 3 ). Liver volume and IRV in 4DMRI increased by 4.0% and 6.6%, respectively, compared with 4DCT. The difference in tumor motion by T2w-4DMRI based on the centroid was greater than that of 4DCT in the L/R, A/P, and S/I directions, and the average displacement differences were 2.6, 2.8, and 6.9 mm, respectively. The severe artifacts in 4DCT were 47.8% (11/23) greater than in 4DMRI 17.4% (4/23).Conclusions: Compared with 4DCT, T2-weighted and navigator-triggered 4DMRI produces fewer artifacts and larger motion differences in hepatic intrafraction tumors, which is a feasible technique for primary liver cancer treatment planning. … (more)
- Is Part Of:
- Technology in cancer research & treatment. Volume 20(2021)
- Journal:
- Technology in cancer research & treatment
- Issue:
- Volume 20(2021)
- Issue Display:
- Volume 20, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 20
- Issue:
- 2021
- Issue Sort Value:
- 2021-0020-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10
- Subjects:
- 4DCT -- MRI -- respiratory motion simulation -- liver cancer -- tumor delineation -- radiotherapy
Oncology -- Periodicals
Cancer -- Diagnosis -- Periodicals
Cancer -- Treatment -- Technological innovations -- Periodicals
616.994 - Journal URLs:
- http://tct.sagepub.com/ ↗
http://www.tcrt.org ↗
http://www.sagepub.com ↗ - DOI:
- 10.1177/15330338211045499 ↗
- Languages:
- English
- ISSNs:
- 1533-0346
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19940.xml