Tattoo Inks for Optical Biosensing in Interstitial Fluid. Issue 21 (12th September 2021)
- Record Type:
- Journal Article
- Title:
- Tattoo Inks for Optical Biosensing in Interstitial Fluid. Issue 21 (12th September 2021)
- Main Title:
- Tattoo Inks for Optical Biosensing in Interstitial Fluid
- Authors:
- Pazos, Martalu D.
Hu, Yubing
Elani, Yuval
Browning, Kathryn L.
Jiang, Nan
Yetisen, Ali K. - Abstract:
- Abstract: The persistence of traditional tattoo inks presents an advantage for continuous and long‐term health monitoring in point of care devices. The replacement of tattoo pigments with optical biosensors aims a promising alternative for monitoring blood biomarkers. Tattoo inks functionalization enables the control of interstitial biomarkers with correlated concentrations in plasma, to diagnose diseases, evaluate progression, and prevent complications associated with physio pathological disorders or medication mismatches. The specific biomarkers in interstitial fluid provide a new source of information, especially for skin diseases. The study of tattoo inks displays insufficient regulation in their composition, a lack of reports of the related complications, and a need for further studies on their degradation kinetics. This review focuses on tattoo optical biosensors for monitoring dermal interstitial biomarkers and discusses the clinical advantages and main challenges for in vivo implantation. Tattoo functionalization provides a minimally invasive, reversible, biocompatible, real‐time sensing with long‐term permanence and multiplexing capabilities for the control, diagnosis, and prevention of illness; it enables self‐controlling management by the patient, but also the possibility of sending the records to the doctor. Abstract : The replacement of tattoo pigments with optical biosensors enables a minimally invasive, reversible, biocompatible, and real‐time platform withAbstract: The persistence of traditional tattoo inks presents an advantage for continuous and long‐term health monitoring in point of care devices. The replacement of tattoo pigments with optical biosensors aims a promising alternative for monitoring blood biomarkers. Tattoo inks functionalization enables the control of interstitial biomarkers with correlated concentrations in plasma, to diagnose diseases, evaluate progression, and prevent complications associated with physio pathological disorders or medication mismatches. The specific biomarkers in interstitial fluid provide a new source of information, especially for skin diseases. The study of tattoo inks displays insufficient regulation in their composition, a lack of reports of the related complications, and a need for further studies on their degradation kinetics. This review focuses on tattoo optical biosensors for monitoring dermal interstitial biomarkers and discusses the clinical advantages and main challenges for in vivo implantation. Tattoo functionalization provides a minimally invasive, reversible, biocompatible, real‐time sensing with long‐term permanence and multiplexing capabilities for the control, diagnosis, and prevention of illness; it enables self‐controlling management by the patient, but also the possibility of sending the records to the doctor. Abstract : The replacement of tattoo pigments with optical biosensors enables a minimally invasive, reversible, biocompatible, and real‐time platform with long‐term permanence and multiplexing capabilities for the control, diagnosis, and prevention of illness by monitoring interstitial biomarkers with correlated concentrations in plasma. The interaction of the biomarker with the biosensor produces a signal proportional to the biomarker concentration in the interstitial fluid. … (more)
- Is Part Of:
- Advanced healthcare materials. Volume 10:Issue 21(2021)
- Journal:
- Advanced healthcare materials
- Issue:
- Volume 10:Issue 21(2021)
- Issue Display:
- Volume 10, Issue 21 (2021)
- Year:
- 2021
- Volume:
- 10
- Issue:
- 21
- Issue Sort Value:
- 2021-0010-0021-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2021-09-12
- Subjects:
- health monitoring -- interstitial fluids -- optical biosensors -- tattoos
Biomedical materials -- Periodicals
610.28 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2192-2659 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/adhm.202101238 ↗
- Languages:
- English
- ISSNs:
- 2192-2640
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0696.854650
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19942.xml