Testing of a novel Valsalva Assist Device with supine and modified positions in healthy volunteers. Issue 1 (1st December 2018)
- Record Type:
- Journal Article
- Title:
- Testing of a novel Valsalva Assist Device with supine and modified positions in healthy volunteers. Issue 1 (1st December 2018)
- Main Title:
- Testing of a novel Valsalva Assist Device with supine and modified positions in healthy volunteers
- Authors:
- FitzGerald, Isabel
Ewings, Paul
Lang, Iain
Appelboam, Andy - Abstract:
- Abstract : Background: The Valsalva manoeuvre (VM) is used to treat supraventricular tachycardia (SVT) by inducing a vagal response (drop in HR). There is debate as to the best position in which to carry out the VM and how the strain should be delivered in practice. We aimed to compare vagal responses induced with supine and modified VMs using strains delivered with a standardised manometer or novel Valsalva Assist Device (VAD), a simple device to provide resistance to exhalation. Methods: We conducted a repeated measures randomised trial of four VMs (two supine VM and two modified VMs), in healthy adult volunteers, with strains delivered using an adapted sphygmomanometer (manometer) or a VAD. Changes in HR, pressure and duration of strain and adverse events were monitored and compared between the techniques and devices. The trial was approved by the University of Exeter Medical School Research ethics committee. Results: 75 healthy participants aged 19–55 years were recruited over a 4-month period. A mixed-effects linear regression showed the modified VM resulted in a 3.8 beats per min (bpm) greater drop in HR compared with the supine VM (p=0.002, 95% CI 2.2 to 5.4). VM strains produced by the VAD were of a similar pressure but of slightly shorter duration and resulted in a 1.9 bpm smaller drop in HR compared with the manometer (p=0.01, 95% CI 0.4 to 3.4). There were no differences in adverse events. Conclusions: Modified VM was associated with a greater drop in HR than aAbstract : Background: The Valsalva manoeuvre (VM) is used to treat supraventricular tachycardia (SVT) by inducing a vagal response (drop in HR). There is debate as to the best position in which to carry out the VM and how the strain should be delivered in practice. We aimed to compare vagal responses induced with supine and modified VMs using strains delivered with a standardised manometer or novel Valsalva Assist Device (VAD), a simple device to provide resistance to exhalation. Methods: We conducted a repeated measures randomised trial of four VMs (two supine VM and two modified VMs), in healthy adult volunteers, with strains delivered using an adapted sphygmomanometer (manometer) or a VAD. Changes in HR, pressure and duration of strain and adverse events were monitored and compared between the techniques and devices. The trial was approved by the University of Exeter Medical School Research ethics committee. Results: 75 healthy participants aged 19–55 years were recruited over a 4-month period. A mixed-effects linear regression showed the modified VM resulted in a 3.8 beats per min (bpm) greater drop in HR compared with the supine VM (p=0.002, 95% CI 2.2 to 5.4). VM strains produced by the VAD were of a similar pressure but of slightly shorter duration and resulted in a 1.9 bpm smaller drop in HR compared with the manometer (p=0.01, 95% CI 0.4 to 3.4). There were no differences in adverse events. Conclusions: Modified VM was associated with a greater drop in HR than a supine VM with no increase in adverse events in healthy volunteers. The VAD can be used to safely generate the recommended VM strain pressure, but produced a smaller drop in HR compared with a manometer and requires modification to enable the recommended strain duration to be achieved consistently. Trial registration number: NCT03298880 . … (more)
- Is Part Of:
- Emergency medicine journal. Volume 36:Issue 1(2019)
- Journal:
- Emergency medicine journal
- Issue:
- Volume 36:Issue 1(2019)
- Issue Display:
- Volume 36, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 36
- Issue:
- 1
- Issue Sort Value:
- 2019-0036-0001-0000
- Page Start:
- 27
- Page End:
- 31
- Publication Date:
- 2018-12-01
- Subjects:
- acute care -- cardiac care -- arrhythmia
Emergency medicine -- Periodicals
616.02505 - Journal URLs:
- http://www.bmj.com/archive ↗
https://emj.bmj.com/ ↗ - DOI:
- 10.1136/emermed-2018-208004 ↗
- Languages:
- English
- ISSNs:
- 1472-0205
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19923.xml