USING A NOVEL NON-INVASIVE, CUFF-LESS, WIRELESS DEVICE FOR 24-HOUR AMBULATORY BLOOD PRESSURE MONITORING. (April 2021)
- Record Type:
- Journal Article
- Title:
- USING A NOVEL NON-INVASIVE, CUFF-LESS, WIRELESS DEVICE FOR 24-HOUR AMBULATORY BLOOD PRESSURE MONITORING. (April 2021)
- Main Title:
- USING A NOVEL NON-INVASIVE, CUFF-LESS, WIRELESS DEVICE FOR 24-HOUR AMBULATORY BLOOD PRESSURE MONITORING
- Authors:
- Gepner, Yftach
Nachman, Dean
Gilan, Adi
Goldstein, Nir
Constantini, Keren
Littman, Romi
Eisenkraft, Arik
Grossman, Ehud - Abstract:
- Abstract : Objective: Ambulatory blood pressure monitoring (ABPM) using cuff-based devices is used for diagnosis and treatment of hypertension. Technical limitations, low compliance and complex procedure limit their use. The aim of the present study was to compare a new technique of 24H ABPM using a photoplethysmography (PPG)-based, wearable device to the standard cuff-based device. Design and method: In this prospective study, 24H ABPM was performed using a standard cuff-based device and the PPG-based device (Wrist-monitor) in parallel on volunteers aged 18–65 years, while documenting their daily activities. Level of comfort and activity disturbance of both devices were recorded. Linear regression and Bland-Altman were used to evaluate the agreement between the Wrist-monitor and Holter. Receiver Operating Characteristic (ROC) curve analysis was used to assess the ability of the Wrist-monitor to identify abnormal BP values. Results: The study included 28 subjects (18 men) mean age 41.5 ± 16.2 years. Bland-Altman analysis results in 24H bias of -1.1 mmHg for both diastolic blood pressure (DBP) and systolic blood pressure (SBP). Mean daytime bias was -1.9 mmHg for DBP and SBP, while nighttime bias was smaller (0.7 and 0.4 mmHg for DBP and SBP respectively). ROC curve analysis on all BP readings (n = 2381) yielded a mean area under the curve (AUC) for 24 hours of 0.965 for both SBP and DBP. 24H ABPM with the Wrist-monitor caused significantly less inconvenience compared to theAbstract : Objective: Ambulatory blood pressure monitoring (ABPM) using cuff-based devices is used for diagnosis and treatment of hypertension. Technical limitations, low compliance and complex procedure limit their use. The aim of the present study was to compare a new technique of 24H ABPM using a photoplethysmography (PPG)-based, wearable device to the standard cuff-based device. Design and method: In this prospective study, 24H ABPM was performed using a standard cuff-based device and the PPG-based device (Wrist-monitor) in parallel on volunteers aged 18–65 years, while documenting their daily activities. Level of comfort and activity disturbance of both devices were recorded. Linear regression and Bland-Altman were used to evaluate the agreement between the Wrist-monitor and Holter. Receiver Operating Characteristic (ROC) curve analysis was used to assess the ability of the Wrist-monitor to identify abnormal BP values. Results: The study included 28 subjects (18 men) mean age 41.5 ± 16.2 years. Bland-Altman analysis results in 24H bias of -1.1 mmHg for both diastolic blood pressure (DBP) and systolic blood pressure (SBP). Mean daytime bias was -1.9 mmHg for DBP and SBP, while nighttime bias was smaller (0.7 and 0.4 mmHg for DBP and SBP respectively). ROC curve analysis on all BP readings (n = 2381) yielded a mean area under the curve (AUC) for 24 hours of 0.965 for both SBP and DBP. 24H ABPM with the Wrist-monitor caused significantly less inconvenience compared to the Holter (p < 0.001). Conclusions: The cuff-less device provides comparable measurements to those obtained with the currently used ABPM device, with significantly less inconvenience to the subject. … (more)
- Is Part Of:
- Journal of hypertension. Volume 39(2021)e-Supplement 1
- Journal:
- Journal of hypertension
- Issue:
- Volume 39(2021)e-Supplement 1
- Issue Display:
- Volume 39, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 39
- Issue:
- 1
- Issue Sort Value:
- 2021-0039-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-04
- Subjects:
- Hypertension -- Periodicals
Hypertension -- Periodicals
616.132005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://journals.lww.com/jhypertension/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00004872-000000000-00000 ↗
http://www.jhypertension.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/01.hjh.0000745852.68344.1a ↗
- Languages:
- English
- ISSNs:
- 1473-5598
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5004.510000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19886.xml